1 / 9

Volumetric Analysis

Volumetric Analysis. Apparatus. The Volumetric Flask. Volumetric Flask. Weigh out a specific mass of anhydrous sodium carbonate on a clean, dry clock glass accurate to 0.01g. Add the solute to a beaker containing a small volume of deionised water.

huey
Télécharger la présentation

Volumetric Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Volumetric Analysis Apparatus

  2. The Volumetric Flask

  3. Volumetric Flask • Weigh out a specific mass of anhydrous sodium carbonateon a clean, dry clock glass accurate to 0.01g. • Add the solute to a beaker containing a small volume of deionised water. • Using a wash bottle wash all traces of the solute from the clock glass into the beaker. • Stirwithclean glass rod to dissolve • Using a funnel transfer the contents of the beaker into a clean dry volumetric flask. • Wash all traces from the beaker, glass rod and funnel into the flask. • add deionised wateruntil the level is 1 cm below the gradation mark. • Using a dropper fill the rest of the volumetric flask • until the bottom of the meniscus is on the mark.

  4. Volumetric Analysis • Stopper the flask and invert about 30 times. • This ensures the mixture is homogenous.

  5. The Pipette • Rinse with deionised water. • Rinse with some of the solution it is to contain. • Use a pipette filler to draw the level of the liquid above the graduation mark and then allow to empty till at bottom of the meniscus. • Allow to empty with gravity,to remove adhering drop touch off side of glass. Dont blow: its calibrated for this

  6. The Burette

  7. The Burette • Rinse with deionised water. • Rinse with some of the solution it is to contain. • Use a small funnel when filling the burette. • The burette is filled almost to the top and then the tap is opened to fill the part below the tap and so the meniscus is on the bottom of the graduation mark

  8. Conical Flask

  9. Conical Flask • Its design allows it to be swirled without the solution splashing out. • Before use, wash out with deionised water. • Do not wash out with the solution it is to contain • Can rinse with deionised water during titration because no effect on number of moles in flask • Place over coloured tile to help see colour change

More Related