1 / 33

The HERMES RICH: past and future

The HERMES RICH: past and future. PSHP Frascati, October 20 th -2010. Raffaele De Leo / University of Bari and INFN Bari. Overview of the HERMES RICH HERMES RICH performances HERMES RICH in SBS. HERMES Experimental Setup. 2 RICH identical modules.

huseby
Télécharger la présentation

The HERMES RICH: past and future

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The HERMES RICH: past and future PSHP Frascati, October 20th-2010 DeLeo, Cisbani / HERMES RICH Raffaele De Leo / University of Bari and INFN Bari

  2. Overview of the HERMES RICH • HERMES RICH performances • HERMES RICH in SBS DeLeo, Cisbani / HERMES RICH

  3. HERMES Experimental Setup DeLeo, Cisbani / HERMES RICH 2 RICH identical modules

  4. ’97: the HERMES dual radiator RICH proposal • focalized R = 2.2 m • n(aerogel)=1.03, C=242 mrad • n(C4F10)= 1.00137 • Npe (aerogel) = 10 • /(/ring) =1.2 % (4.1% / pe) • (/ring) = 3 mrad • C-Ck (7GeV,n =1.03) = 9mrad qC ±3s ring resolution

  5. HERMES RICH module layout 147 63 101 180 48 DeLeo, Cisbani / HERMES RICH 126 281 units in cm

  6. Radiators DeLeo, Cisbani / HERMES RICH Refractive Index n (633 nm)=1.03 Matsushita (hydrophobic) + C4F10 Gas, n(633 nm)=1.00137

  7. Optics DeLeo, Cisbani / HERMES RICH

  8. Photon Detector plane DeLeo, Cisbani / HERMES RICH PMT: 18 mm diameter

  9. ~20% of the HERMES RICH PMT array Light Collection DeLeo, Cisbani / HERMES RICH

  10. Electronics DeLeo, Cisbani / HERMES RICH • VME based, 20 MHz bus from front-end to VME • less than 30 ms to transfer data to VME • able to keep data up to 800 ns (selectable) since trigger • down to 50 ns gate width • No time information

  11. nov. ‘98

  12. In operation: 98-00, 02-08

  13. HERMES RICH performances DeLeo, Cisbani / HERMES RICH

  14. T  Cher. ’s  photoelectrons exp Npe (calc.) 10±2 (400 nm) = 2.3cm

  15. % /pe = geometrical contributions to C 1) pixel 2) focal plane a) (dq/q)opt.aber.= (d/R)2 = 0.5% b) (dq/q)surf.imp.= 0.3 % mirror alignment a)+b)(dq/q)mirror= 0.6 % / pe 3) point emiss. (dq/q) point= 0.7 % / pe

  16. aerogel opt. properties contrib.s to C • 1) n dispersion in the different tiles • 2) chromatic dispersion n() • 3) forward scattering • 4) tile surface irregularities aerogel Selected 850 tiles over 1200 11x11x1 cc from Matsushita 2 planes, 5 rows, 17 columns, 5 layers one aerogel radiator

  17. Hadron PID: HERMES RICH 5.5 GeV K+ REAL DATA from NIMA 479 (2002) 511 14.6 GeV e- 1.5 GeV p- DeLeo, Cisbani / HERMES RICH Two radiators: aerogel and gas PMTs as photon detector Focusing Optics C4F10 Reference: NIMA 479 (2002) 511-530

  18. Pixel 2.3 Mirror0.6 Point emiss.0.7 n disp. 0.5 Chromatic 1.3 Forw.Scatt. 0.4 Surface 0.4 Total (calc.)/pe 2.9 Total (exp.)/pe 3.3 Npe (exp.) 10 exp. vs calc. angle resolution (%) HERMES c for single pe pe > 5 GeV Npe = 10 /=3.3%/pe DeLeo, Cisbani / HERMES RICH / = 1.1% /ring Largest error from pixel size (by design!)

  19. qC ring n (e+>5GeV) plot vs day n DeLeo, Cisbani / HERMES RICH

  20. average n (e+>5GeV) Dn ~ 0.0003 Dn ~ 0.0003 DeLeo, Cisbani / HERMES RICH Dn ≈ 3 *10-4 in 10 years! Dn ≈ 1*10-4 in the last 5 years!

  21. pe reconst.starting point distribution e > 5 GeV DeLeo, Cisbani / HERMES RICH a real stable RICH ! DNpe< 0.2 0.3% in 10 years!

  22. HERMES RICH in SBS@HallA DeLeo, Cisbani / HERMES RICH

  23. one RICH module now @ UVa (thanks to Gordon) RICH DeLeo, Cisbani / HERMES RICH Aerogel Spare Now stored at UVa under safe/controlled conditions + additional wall of spare Aerogel from the other module.

  24. SIDIS (Cond.appr. Exp.): Setup and parameters e+3He→e’+p(K)+X BB: e-arm at 30o  = 45 msr GEM Tracker Gas Cherenkov Shower  GMn/PR-09-019 SBS: h-arm at 14o  = 50 msr GEM tracker excellent PID / RICH Hadron CALO DeLeo, Cisbani / HERMES RICH Event rate: ~104×HERMES 60 days of production expected stat. accuracy: 10*better than HERMES on proton Beam: 50 A, E=8.8 and 11 GeV (80% long. Pol.) Target: 65% polarized 3He  GEn(2)/PR-09-016  Luminosity: 1.4×1037 cm-2s-1

  25. HERMES RICH in SBS (SIDIS Exp.) DeLeo, Cisbani / HERMES RICH (old GEM setup)

  26. Challenges in large acceptance/high luminosity (SIDIS exp.) • SBS Tracker rate 60 kHz/cm2(bck, soft photons) • RICH PID: high segmentation of photon detector (2000 PMT): • Expected 35 extra hits/event from soft photons (Compton electrons in aerogel) -- 50 ns gate width 2-5% occupancy DeLeo, Cisbani / HERMES RICH (2009 estimation)

  27. To be done • Present RICH performance ? • Characterize the actual RICH and in particular evaluate the aerogel performance (transparency, refractive index …) ? • Simulation • Study rate capability of the RICH • Evaluate required segmentation • Are time information needed? Is the PCOS4 electronics still adequate? DeLeo, Cisbani / HERMES RICH

More Related