Results Achieved visible focused beam that converged at the center of the device

Construction of the S ix I on G un F usion E xperiment (SIGFE) Matt K. Michalak, Brian J. Egle University of Wisconsin – Madison. Alignment Individual lenses are able to be adjusted using 4 set screws in the optic mount to make lens axes concentric

imaran
Télécharger la présentation

Results Achieved visible focused beam that converged at the center of the device

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Construction of the Six Ion Gun Fusion Experiment (SIGFE)Matt K. Michalak, Brian J. EgleUniversity of Wisconsin – Madison • Alignment • Individual lenses are able to be adjusted using 4 set screws in the optic mount to make lens axes concentric • Guns are pivoted on two axes with the gun mount swivel plate to focus ion beams at the center • Ground steel rods were used to • align lenses in each gun • These same rods were used to • focus each gun to the center • Objectives • Build a precise, symmetric machine • Stand-off high voltages at close distances • Align lenses in guns • Focus guns at center of device Manufacturing • All lenses manufactured in-house on a computer numerically controlled (CNC) lathe • Settings on lathe were such that machined surfaces were very smooth • Variance between lenses was within 0.05 mm • Results • Achieved visible focused beam • that converged at the center of the • device • High Voltage • Special design considerations were taken to stand-off the high electric fields between lenses • Angling electrode-insulator-vacuum junction, reduced the electric field at the cathode triple point by approximately a factor of 5 • All metal surfaces were sanded to 600 grit and then polished with abrasive cloth to eliminate electric field enhancements at sharp points on the electrodes Above: Cross sectional CAD drawing of the SIGFE Below: Completed SIGFE with one gun removed • Neutron rates vary distinctly for aligned and misaligned lenses • Summary • Lenses were machined to tolerances of ± 0.05 mm • Stable device operation at cathode voltage of 150 kV with insulator standoff distances of 40 mm • Lenses aligned to within 0.4 mm on center • Visible ion beams focused at center of device Simulations led to current design of insulator caps 5 MV/m field at junction 90 degree interface 10 MV/m field at junction 90 degree interface with gap 2 MV/m and <1 MV/m in the left and right, respectively

More Related