1 / 31

Future Imaging Atmospheric Cherenkov Telescopes:

Future Imaging Atmospheric Cherenkov Telescopes: Performance of Possible Array Configurations for g -photons in the GeV-TeV Range. S. Sajjad, A. Falvard and G. Vasileiadis LPTA, Université Montpellier 2, CNRS/IN2P3, Montpellier, France. ICRC’07- Merida. Choices and assumptions.

ingridbrown
Télécharger la présentation

Future Imaging Atmospheric Cherenkov Telescopes:

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Future Imaging Atmospheric Cherenkov Telescopes: Performance of Possible Array Configurations for g-photons in the GeV-TeV Range S. Sajjad, A. Falvard and G. Vasileiadis LPTA, Université Montpellier 2, CNRS/IN2P3, Montpellier, France ICRC’07- Merida

  2. Choices and assumptions • Focus on gamma shower simulation and reconstruction: Source, shower core, energy and effective area • gamma-hadron identification issues have not been touched • Parabolic mirrors • In order to focus on the issues concerning the showers themselves, we have ignored: • geomagnetic field • night sky background • image cleaning

  3. The Tools: • Package developed for • Simulating the response of IACT arrays to atmospheric showers • Reconstructing the various shower parameters  will be made public

  4. The Tools: Simulation Shower simulation done through CORSIKA (version 6.020 currently used - will be updated)

  5. The Tools: Simulation Shower simulation done through CORSIKA (version 6.020 currently used will be updated) • Telescope simulation • Uses CORSIKA output

  6. The Tools: Simulation Shower simulation done through CORSIKA (version 6.020 currently used will be updated) • Telescope simulation • Uses CORSIKA output • Reflection of Cherenkov photon by a parabolic mirror onto camera plane

  7. The Tools: Simulation Shower simulation done through CORSIKA (version 6.020 currently used will be updated) • Telescope simulation • Uses CORSIKA output • Reflection of Cherenkov photon by a mirror onto camera plane • Variable diametre, focal length, camera size, pixel size, camera position

  8. The Tools: Simulation Shower simulation done through CORSIKA (version 6.020 currently used will be updated) • Telescope simulation • Uses CORSIKA output • Reflection of Cherenkov photon by a mirror onto camera plane • Variable diametre, focal length, camera size, pixel size, camera position • Position and orientation of individual telescopes

  9. The Tools: Simulation Shower simulation done through CORSIKA (version 6.020 currently used will be updated) • Telescope simulation • Uses CORSIKA output • Reflection of Cherenkov photon by a mirror onto camera plane • Variable diametre, focal length, camera size, pixel size, camera position • Position and orientation of individual telescopes • Array simulation (simulate up to 100 telescopes)

  10. The Tools: Shower reconstruction source position • Source reconstruction Superposed images from all tels in the camera frame of ref.: • The axes from all images should meet at one point: the source • Each axis should pass from the centroid of corresponding image • The distance of the pixels from the corresponding axis should be minimum • The transverse profile of images is considered to be Gaussian

  11. The Tools: Shower reconstruction source position • Source reconstruction Superposed images from all tels in the camera frame of ref.: • The axes from all images should meet at one point: the source • Each axis should pass from the centroid of corresponding image • The distance of the pixels from the corresponding axis should be minimum • The transverse profile of images is considered to be Gaussian Likelihood function

  12. The Tools: Shower reconstruction -ln(Lall) map source position • Source reconstruction Superposed images from all tels in the camera frame of ref.: • The axes from all images should meet at one point: the source • Each axis should pass from the centroid of corresponding image • The distance of the pixels from the corresponding axis should be minimum • The transverse profile of images is considered to be Gaussian Likelihood function

  13. The Tools: Shower reconstruction -ln(Lall) map source position • Source reconstruction Superposed images from all tels in the camera frame of ref.: • The axes from all images should meet at one point: the source • Each axis should pass from the centroid of corresponding image • The distance of the pixels from the corresponding axis should be minimum • The transverse profile of images is considered to be Gaussian Likelihood function

  14. -ln(Lall) map N2 d2 d3 N1 d1 core position d4 N3 The Tools: Shower reconstruction • Shower core reconstruction • Same principle as for source reconstruction • Calculations in the ground frame of reference

  15. -ln(Lall) map N2 d2 d3 N1 d1 core position d4 N3 The Tools: Shower reconstruction • Shower core reconstruction • Same principle as for source reconstruction • Calculations in the ground frame of reference N4 • Energy reconstruction • Uses the linear relationship between shower energy and the average number of photo-electrons in the image

  16. Energy domains and choices for telescopes • The observational issues and physics goals depend on the energy domain • Different parts of the arrays could be optimised for observations in different energy domains

  17. Energy domains and choices for telescopes • The observational issues and physics goals depend on the energy domain • Different parts of the arrays could be optimised for observations in different energy domains • ~300 GeV to a few tens of TeV • Domain where IACT show best performance • Good reconstruction and gamma-hadron discrimination with10-15m diam. telescopes • Need to improve sensitivity • Large number of medium sized tels over a large surface  12.5 m telescopes

  18. Energy domains and choices for telescopes • The observational issues and physics goals depend on the energy domain • Different parts of the arrays could be optimised for observations in different energy domains • ~Below 300 GeV • Showers are smaller, more fluctuations, poorer reconstruction and gamma-hadron separation • Fluxes from sources tend to be higher • Need to collect more Cherenkov light from showers • A few telescopes with large diam. telescopes  30 m telescopes

  19. Selection of array parameters Optimum telescope separation studied in terms of shower reconstruction Square unit of 4 telescopes preliminary Trigger: at least two telescopes with 50 p. e.

  20. Selection of array parameters 400 m 1200 m Optimum telescope separation studied in terms of shower reconstruction preliminary Trigger: at least two telescopes with 50 p. e.

  21. Selection of array parameters 400 m 1200 m Optimum telescope separation studied in terms of shower reconstruction preliminary Trigger: at least two telescopes with 50 p. e.

  22. 30 m diam. 4 tels 200 m For 1800 m a. s. l. Optimum for 50 GeV(tel. diam. 30m) ~200m

  23. 420 m 140 m 100 m 30 m diam. 4 tels 400 m 12.5 m diam. 33 tels For 1800 m a. s. l. Optimum for 300 GeV(tel. diam. 12.5m) ~140m Optimum for 50 GeV(tel. diam. 30m) ~200m

  24. 420 m 140 m 100 m 30 m diam. 30 m diam. 5 tels 4 tels 400 m 12.5 m diam. 12.5 m diam. 49 tels 33 tels Two telescope configurations

  25. 360 m 120 m 30 m diam. 30 m diam. 5 tels 4 tels 87 m 350 m 12.5 m diam. 12.5 m diam. 49 tels 33 tels At 3600 m  System rescaled Two telescope configurations

  26. X103 Results Effective area 1800 m Typical effective areas of 4 tel systems: 0.4-0.5 X106 m2

  27. Results Four telescope array (FTA) diam=12.5m Source reconstruction precision Large arrays (LA) Reconstruction done for cores within an 800X800 m2 region (after trigger)

  28. Core reconstruction precision Results Typical precision on shower core for 1 TeV for a 4 tel array Reconstruction done for cores within an 800X800 m2 region (after trigger)

  29. Results Energy resolution Typical precision on shower core for 1 TeV for a 4 tel array

  30. Summary • A public package capable of simulating IACT system response to atmospheric showers and reconstructing gamma-ray parameters has been realised. • It was used to study the effect of telescope separation on various reconstruction parameters. • Two arrays with 37 and 54 telescopes have been studied at 1800 m and 3600 m for gamma parameter reconstruction and show considerable improvement with respect to the current generation.