1 / 22

Environmental Noise Studies (May-July’09)

I.Fiori, Virgo Week, Commissioning Meeting, 20 July 2009. Environmental Noise Studies (May-July’09). by The VIRGO Commissioning Team and EGO Vacuum, Electronics, Infrastructure Teams. Topics. Diffused light from End benches External Injection Bench Turbo pumps Cryo-trap

ishi
Télécharger la présentation

Environmental Noise Studies (May-July’09)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. I.Fiori, Virgo Week, Commissioning Meeting, 20 July 2009 Environmental Noise Studies (May-July’09) by The VIRGO Commissioning Team and EGO Vacuum, Electronics, Infrastructure Teams

  2. Topics • Diffused light from End benches • External Injection Bench • Turbo pumps • Cryo-trap • Coil Drivers crates • U-pure-water sys (investigation) • HVAC

  3. Diffused light from WEB was limiting sensitivity before May 2009 (purple) • WEB motion at legs resonance (20Hz) has been reduced by: • Slow down HVAC fan (-10%) • New cover box (more rigid and compact) • Resonant damper on bench Diffused light from WEB,mitigation of bench motion

  4. Microseism • VSR2 inauguration, with exceptional microseism (<1% of time) • Possible intervention: • Replacement of WE tower output window: tilted and AR coated • (same as was done at NE). • Could reduce noise coupling by a factor 1.5 - 2.

  5. Noise in 40-50Hz Contributions not yet fully understood, but progressing: • TCS noise seems to contribute (see G.Vajente). • Some cooling fans (turbo pumps, CD crates) found to contribute and are being mitigated (see later in this talk). • External Injection Bench is suspected to couple seismic noise in this region because of its large motion at 41-47 Hz (bench vertical modes). EIB seismic noise Projection based on OLD measurement (Feb. 2009)

  6. EIB noise? • Coherence changes , and now it is much lower than in May. • Coupling path is being investigated (indications that it might depend on IMC transmitted power). • Understand coupling and study possible reduction of EIB motion is also important for V+MS.

  7. EIB vertical resonances: investigation F.Richard and T.Zelenova Ruggi, Paoletti, Fiori • Simulation: 40 Hz resonance is a mechanical mode of the top plate of bench legs. • Measurement with • mini-accelerometers • confirmed prediction.

  8. E.Genin EIB: mitigations? • Stiffening actual legs: attemps made but not successful • Sorbothane: pads between bench and legs, can move vertical mode down to 15 Hz, and well damped • BUT, Test in Optics Laboratory: >> measured large drifts (100m) which cannot be tollerated by BMS. OTHER SOLUTIONS: • Resonant damper (both V and H modes): under study (thanks F.Frasconi). Tests off-line, if good results, installation “easy”. • Conical legs: (have some on site) solid material, tests in Optics-Lab. >>> Role of EIB noise in V+MS to be addressed.

  9. Turbo pumps, related • Excess noise at InjectionBrewster • NI tower motion • Peaks from Turbo cooling fans

  10. Excess noise at INJ Brewster • eLogs 23216, 23261, 23267, 23307, 23419 • Evidence: 100-200Hz noise coherent with seismic noise at INJ Brewster, but also EIB and BMS. • Noise decrease when IB pump off. • Residual coherence from PR turbo pump. IB and PR pumps ON IB turbo OFF PR pump OFF Effect of switching off IB pump:

  11. Excess noise at INJ Brewster ACTIONS: (Pasqualetti and Vacuum Team) • 1) IB pump now kept off, and replaced by MC pump (MC pump looks “safer”, i.e. no coherence with dark fringe). • 2) Bellow installed on PR pump: cut all pump noise at Brewster below 100Hz Switching on PR pump after bellow installation: NO EFFECT! Only noise from PR reaching INJBrew is that of cooling fans. >>> Role of INJ Brewster to be better studied for V+MS.

  12. Bellow at PR • lpaoli, vacuum team - 14:44, Tuesday 30 June 2009 (23412)

  13. NI motion Ruggi (eLogs 23408, 23436, 23452, 23457) • ITF was disturbed by repetitive events of NI motion, which caused unlocks or holes in the horizon. • Tracked to Saturation of one accelerometer on NI top stage. • The NI top stage seems more coupled to environment than other towers (reasons to be investigated). • Meanwhile, ACTIONS: • Temporary cure: tower vibration reduced by switching off NI turbo pump and use Auxiliary NI pump. • Installation of bellow on NI turbo (soon, during Tuesday maintenances).

  14. Turbo cooling fans • eLogs 23353, 23757, Vacuum team • Peaks at 45Hz from WI turbo, coherent with TCS bench seism. • Mitigation attempt: fans detached from turbo and attached to platform.  seismic excitation reduced (tower, TCS bench) by 5-10. • First action, to test the damping principle. The method of damping shall be better defined, if needed implemented on all disturbing fans, in the forthcoming maintenance breaks.

  15. Fans of Coil Drivers crates: BS and NE • eLogs: 23471, 23714; 23684, 23536, 23483, 23477, 23410: Marque, Vajente, Huet, Nocera • Peaks in dark fringe at (44Hz, 88Hz) and (28Hz, 56Hz, 84Hz) • present in NE/BS coil current monitoring even with ITF unlocked (if coil driver in low noise) • Disappear when coil driver fans are switched off.

  16. CD crates, mitigations: FACTS: • Culprit seems magnetic noise emission from crates fans. Magnetic noise seems local to crate, not present few meters away ( coupling: likely not Env. to mirrors magnets, but via the current sent to the coils). 2) Noisy crates (NE and BS) are of one type. No noise detected from the CD crate of WE, which is of different type. ACTIONS: • Noise path inside crate to be better investigated (mechanical, ground loops, electromagnetic...) to plan proper actions. • Simple check: if problem related just to fans type (if so, change just fans could be sufficient). • Ultimatey, evaluate if necessary to purchase crates of the “good” type.

  17. “Cryo-trap noise” eLogs: 23722, 23637, 23636, 23634, 23794, Swinkels, Ruggi, Vajente. • Noise increase in 60-120Hz after routine Cryo-trap refills • Corresponds to increased vibration of LN tank and pipe.

  18. “Cryo-trap noise” • Noise (dark fringe and seismometers) decreases with time constant of 1.5day, which is correlated to the average temperature of the tank. • When “listening” to sismometer on Cryo-trap, it sounds like “bubbles”. • Vacuum group interested to understand this mechanisms for future installations. Tests to be planned during next maintenances. Sensitivity affected mostly in 60-70Hz

  19. “Cryo-trap noise”: mitigation? • Hypothesis: since the removal of the suspended baffles(May 15), the wall of the Cryo-trap can now be seen from the detection bench. Any light scattering e.g. from L1 could thus hit the wall of the tank. Possible ACTIONS: • Install a new baffle, to cover the “naked” Cryotrap (careful design to avoid upconversion noise effects, very rigid one) • Reduce back-reflected light from L1, replace with better lens superpolished (J.Marque).

  20. Infrastructures related noises • Water pump #1: Noisy during VSR1. Replaced. New pump produces no detectable environmenatal noise in CB hall. However, pump is off, apparently not needed. • U-pure-water production sys: needs to run in stand-by mode during VSR2. Noise investigated (eLog 23519, Ciardelli, Fiori). One pump that starts periodically produces some seismic noise on EIB. No detectable effect in dark fringe. Mitigation tests to do during maintenances.

  21. Infrastructure related noises • Lines in dark fringe (23, 37, 48Hz) associated to DAQ room HVAC (eLog 23736). Some mitigation possible, to be defined.

  22. Thanks also to • J.Ramsay, R.M.Goetz: summer students from IREU program. • Joseph initiated a study of effects of vehicles crossing EGO roads, bridges (shall be ready for following meetings).

More Related