Undulator Cavity BPM Design and Status

Undulator Cavity BPM Design and Status. X-Band Cavity BPM Overview. Cavity BPM system design Current status for prototype testing Planning for first article and production. LTU and Undulator BPM System Specification. In-Tunnel Electronics Block Diagram. X-Band Cavity BPM Design.

isolde
Télécharger la présentation

Undulator Cavity BPM Design and Status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Undulator Cavity BPM Design and Status

  2. X-Band Cavity BPM Overview • Cavity BPM system design • Current status for prototype testing • Planning for first article and production

  3. LTU and Undulator BPM System Specification

  4. In-Tunnel Electronics Block Diagram

  5. X-Band Cavity BPM Design • SLAC selective coupling design utilized to reduce monopole mode • Solid Copper Body • WR-75 waveguide output • Waveguide transition brazed to body

  6. Prototype Cavity BPM Specification

  7. Dipole Cavity Design • Beam pipe radius = 5 mm • Cavity radius = 14.937 mm • Cavity gap = 3 mm • Distance beam axis to bottom of wg = 9.5 mm • Waveguide= 19.05 x 3 mm

  8. Monopole Cavity Design • Beam pipe radius = 5 mm • Cavity radius = 11.738 mm • Cavity gap = 2 mm • Coupling Slot = 4 x 2 mm • Shortest distance from cavity opening to bottom of waveguide=1.734 mm • Waveguide= 19.05 x 3 mm

  9. Cold Test Prototype • Non-vacuum cold test prototype • Removable end caps • Accelerates test fixture development and cold test procedures

  10. Vacuum Window Prototype Cold Test • Utilized standard CPI WR-75 window • Silver plated Kovar/Glass vacuum seal • Window cost $100 vs. $ 218 for Kaman coax feed thru • Insertion Loss < 0.2 dB • Return loss -20dB

  11. Waveguide Transitions Prototype Cold Test • Transitions E plane from 3 mm to 9.53 mm (standard WR-75) • Waveguide transition brazed to body • Insertion Loss < 0.2 dB • Return loss -20dB

  12. Before Soldering Transitions and Windows

  13. X-Band Cavity BPM Cold Test • Waveguide and windows soldered together • Unit is vacuum tight except for removable end caps • First data looks encouraging

  14. Monopole and Dipole Wideband Sweep

  15. Dipole Cavity Design

  16. Monopole Cavity Design

  17. Surface Finish Test • End caps and cavity finish received 32 finish (1 um) • Polishing Monopole cavity end cap to approx 0.1 um • Q improved from 444 to 682

  18. In-Tunnel Receiver Block Diagram

  19. Prototype Receiver Specification

  20. Miteq X-Band Low Noise Receiver • Existing product line • WR 75 Waveguide Interface • Low Noise Figure (2.7 dB) • Budgetary price for (3 channels) $6500.00

  21. Prototype X-Band Low Noise Receivers • Conversion gain 27.5 dB • Over 60 dB dynamic range • Noise Figure 2.5 dB • IF bandwidth 40-80 MHZ • Ready for ITS Installation

  22. Prototype Receiver Data

  23. Phase I Injector Test Stand ITS Install single X-Band Cavity and modified off-the-shelf down converter receiver Mount BPM on Piezo two-axis translation stage Phase II Bypass line or LEUTL test with PC gun Install three X-Band Cavities BPMs Bypass line test with PC gun to start June 06 BPM System Test Approach

  24. Injector Test Stand ITS Beam Parameters • Charge- 1 nC single-bunch • Bunch length- ~ 3 - 4 ps FWHM for ps laser • Spot size on final screen at 5.5 MeV ~ 0.75 mm rms, ps laser

  25. Phase I Data Acquisition Design Approach • Instrument three channel down converters with Struck SIS-3301-105 ADCs 14-bit • Single VME board will provide the data acquisition for 8 channels • Epics driver complete • Digitize horizontal, vertical position and Intensity 0 to 1 volt range • Fit Data to decaying exponential at 50 MHz

  26. Phase I Testing Objectives • Test prototype Cavity BPM, down converter, and data acquisition • Generate preliminary compliance table to specification • Gain operational experience to determine if translation stage is useful, what are optimum operating parameters

  27. Phase I Schedule Milestones • Design and develop prototype Cavity BPM • Prototype non vacuum • Jan 06 • Build single Cavity BPM • Feb 06 • Cold Test • Feb 06 • Install cavity BPM into ITS and Test • Feb 06

  28. Phase II Schedule Milestones • Refine design and develop First Article Cavity BPM and support hardware • March 06 • Build 3 Cavity BPMs • March 06 • Cold Test • May 06 • Install 3 cavity BPMs into APS PAR/Booster bypass line or LEUTL and Test • June 06

  29. Phase II Testing Objectives • First Article Prototypes evaluated • Test three BPM separated by fixed distance to determine single-shot • Complete test matrix

  30. LTU and Undulator Planning • Receiver and LO housed in shielded enclosure below girder 20 watt power dissipation maximum • Presently BPM output on wall side • BPM output flexible waveguide section allows movement for alignment

  31. BPM Mounting • BPM connects directly to the girder. • Mechanical adjustment stage used for alignment • BPM and Quad can be adjusted into position independent of one another

  32. Undulator Planning

  33. Production Phase • Production of 2 BPMs for LTU 04/07 • Production of 6 BPMs for undulator 04/07 • Production of 8 BPMs for undulator 06/07 • Production of 3 BPMs for LTU 06/07 • Production of 8 BPMs for undulator 08/07 • Production of 3 BPMs for LTU 08/07 • Production of 11 BPMs for undulator 10/07 • Spares 12/07

  34. Summary • X-Band Cavity BPM development ongoing • Brass body prototype (non-vacuum) • ITS prototype (vacuum) • Receiver Prototype ready for ITS installation • Parts are assembled and tested • Waveguide components received • Data Acquisition • SLAC providing constructive communications and collaboration