1 / 8

Intraocular lens dislocation secondary to haptic torsion

Intraocular lens dislocation secondary to haptic torsion . Lawrence E. Lohman, MD FACS Matthew C. Willett, MD. Author Information. Lawrence E. Lohman, MD FACS -Northeast Ohio Eye Surgeons -Northeastern Ohio Universities College of Medicine -Summa Health Systems

jacinta
Télécharger la présentation

Intraocular lens dislocation secondary to haptic torsion

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Intraocular lens dislocation secondary to haptic torsion Lawrence E. Lohman, MD FACS Matthew C. Willett, MD

  2. Author Information • Lawrence E. Lohman, MD FACS -Northeast Ohio Eye Surgeons -Northeastern Ohio Universities College of Medicine -Summa Health Systems • Matthew C. Willett, MD -Summa Health Systems • Neither author has any financial disclosures • Special thanks to Marc Jones, MD who assisted with the photos in this presentation

  3. Purpose • An 80 year old female patient was referred for evaluation and management of a dislocated posterior chamber one piece acrylic intraocular lens (Alcon SA60AT). Initial surgery was 11 months prior to referral. She suffered blunt trauma to the eye 5 months post op and immediately thereafter noted asymmetric glare surrounding lights and blurred vision. The vision remained unchanged until the time of evaluation.

  4. Patient Evaluation On initial evaluation the best corrected visual acuity was 20/400. The IOL was noted to be inferiorly dislocated with prominent anterior tilting of the superior optic edge (figure right.) The capsule appeared intact and no vitreous was visible anterior to the lens. The haptic at 10 o’clock appeared to be located within the bag (arrows). Marked opacification of the posterior capsule was noted. This allowed limited view of the posterior segment, however the retina appeared grossly intact. The patient was scheduled for possible surgical lens repositioning or exchange.

  5. Results The eye was explored in the operating room. After viscoelastic injection to expand the capsular bag (2,3,4), the superior edge of the lens optic was drawn inferiorly revealing torsion of the superior lens haptic within the bag (5,6) causing it to extend posteriorly and in a clockwise (rather than counter clockwise) direction from the lens optic 3 1 2 4 5 6

  6. Results Using a two handed technique, the haptic was reoriented to its intended configuration (7-10) with immediate lens recentration (11-14). One day after surgery the patient noted resolution of glare symptoms. After Yag capsulotomy BCVA remains 20/25 with no glare symptoms and stable lens position. 7 8 9 10 11 12 13 14

  7. Conclusions • A photographic record is presented of a previously unreported case of traumatic haptic torsion of a one piece acrylic IOL resulting in lens dislocation. The problem was corrected by reorienting the lens haptic to its intended position within the capsular bag, resulting in lens recentration and resolution of patient symptoms.

  8. Lawrence Lohman MD • Lawrence Lohman MD FACS is founder and medical director of Northeast Ohio Eye Surgeons where his practice is limited to Cataract, Cornea and Refractive eye surgeries. He is also founding member and medical director at St Clare Eye Surgery and Laser Center. He teaches at SUMMA Hospitals Medical Center in Akron, Ohio and Northeast Ohio Universities College of Medicine. 