1 / 19

GMA200-MT GMA200-RT GMA200-MW Modules of the Gas detection system

GMA200-MT GMA200-RT GMA200-MW Modules of the Gas detection system. Modules of the GMA200 Gas detection system. Hardware GMA200-MT, GM200-RT, GMA200-MW General description Connection terminals Technical data Power supply. GMA200-MT6/-MT16 General description.

jacob
Télécharger la présentation

GMA200-MT GMA200-RT GMA200-MW Modules of the Gas detection system

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GMA200-MT GMA200-RT GMA200-MW Modules ofthe Gas detectionsystem

  2. Modules ofthe GMA200 Gas detectionsystem Hardware GMA200-MT, GM200-RT, GMA200-MW General description Connection terminals Technical data Power supply

  3. GMA200-MT6/-MT16 General description

  4. GMA200-MT6 Connection assignment (Top hat railmounting) Screw terminals are pluggable in blocks of 9 • Fuses F1 (GMA) and F2 (Transmitter) are behind the terminal cover 11-19 • Switches for RS485-load resistors Rt1,Rt2,Rt3 are behind the terminal cover 61-69

  5. GMA200-MT16 Connection assignment(Top hat railmounting) Screw terminals are pluggable in blocks of 9 • Fuse F1 (GMA)is behind the terminal cover 11-19 • Switches for RS485-load resistors Rt1,Rt2,Rt3 are behind the terminal cover 61-69

  6. GMA200-MT6/-MT16 Technical data - part 1

  7. GMA200-MT6/-MT16 Technical data - part 2

  8. GMA200-RT/-RTD General description

  9. GMA200-RT Connection assignment(Top hat railmounting) Screw terminals are pluggable in blocks of 9 • Fuse F1 (GMA)is behind the terminal cover 11-19 • Switches for RS485-load resistors Rt • are behind the terminal cover 11-19

  10. GMA200-RT/-RTD Technical data - part 1

  11. GMA200-RT/-RTD Technical data - part 2

  12. GMA200-MW16 General description

  13. GMA200-MW16 Connection assignment (Wall mounting) Four-level and Three-level terminal blocks • Fuse F1 (GMA) accessible only by openening the housing cover • Fuse F2 (Transmitter) easy accessible • Switch for RS485-load resistors Rt1,Rt2 behind the Dreistock-Klemmen

  14. GMA200-MW16 Technical data - part 1

  15. GMA200-MW16 Technical data - part 2

  16. GMA200-MW16 Variantsof Power supplies Example for Power supply SET1 Examplefor Power supply SET2

  17. GMA200-MW16 Variantsof Power supplies Example of Power supply SET3 UPS-Detail

  18. GMA200 Relay-Module for Wall mounting Relay-Module GMA200-RTW Wall enclosure with closed upper casing Relay-Module GMA200-RT 15W Power supply

  19. Thankyouforyourattention!

More Related