An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New to RCT DCS component 3.4.1 K. Grogg, M. Grothe

  2. Access Control • Domain: RCT • Groups: RCT_expert, RCT_operator • Users: clazarid, efron, grothe, grogg, jleonard, pamc, tgorski, weinberg • All RCT people belong to RCT_operator • Almost all actions are available to operators • Users grogg & grothe also belong to RCT_expert • Expert has a couple more buttons available for development • We select what buttons/fields are accessible by whom • You must log in to take control of the FSM and have access to certain buttons • Non-RCT people will be able to look at the information, but not take any action

  3. How to log into DCS • On FSM page, or the RMC subpages, click the lock icon in the upper right • Enter your NICE login name and password If you change your password, it might not be updated in PVSS for up to 8 hours

  4. Access to FSM requires Login Logged In: Control of FSM Power_ON/OFF available Access to Alarm Panel NOT logged in: No control of FSM Can’t Power_ON/OFF Cannot see Alarm panel

  5. Buttons Inaccessible Until Login

  6. Operator vs Expert Expert Experts can define new commands Operator A couple other areas within the expert panel are available only to Experts

  7. Alert System • Variables in PVSS, filled from RMC responses, can be set up to auto-generate a Warning or Fault alert when at an undesirable value • These alerts show up automatically in the Alarm Panel • Additional notification actions can be added, such as sending emails or SMS • Severity of alarm will be indicated • Need to decide which variables should have alerts, and which should also have notifications added to them

  8. Alert System Setup • Currently using the monitoring script to send emails and SMS to Monika, Pam, Kira, Jonathan, Jessica, when a Fault occurs • Will be expanded to more variables and all shifters by using the CMS framework alert system • Users and alerts mechanism is in place, but does not appear to be ‘activated’ • CMS alert system is still in development • Needs to be discussed with central DCS and tested with fake alarms • Will have monitoring script email and SMS alerts in place as a backup for now

  9. Alarm Panel Entries – can add Email/SMS to any

  10. More Alarm Panel Entries – can add Email/SMS to any

  11. Alerts Currently Set Up (in principle) • Monitoring script sends email and SMS to Monika, Pam, Kira, Jessica if RMC sends a Fault – i.e., any subsystem Failed • Within CMS framework, alerts will be sent to Monika, Kira, Pam, Jonathan, Christos, Jessica, Marc • Alert notification texts from CMS alert framework: • _RDBArchive.dbConnection.connected DISCONNECTED: FALSE • Our component is not connected to the database and changes to values are not being stored (check Log to see if reconnected) • RMC/RMC1.alarm ALARM: TRUE • RMC 1 Alarm triggered; OR of AlarmStatusFans, AlarmStatusCrates, AlarmStatusSupplies • RMC/RMC2.ONLINE OFFLINE: FALSE • RMC 2 is OFFLINE (no communication) • RMC/RMC3.crateA.secovertwarn WARNING: 30 • RMC 3, crate A has at least one temperature above warning threshold for at least 30 seconds

  12. To Be Decided • Are there any other variables that need alerts? • Are there more variables that need a notification action added to the alert (email/sms)? • The +5V, +12V, -12V analog voltages? • Current in Warning? • Eventually central DCS should have an “RMC script is running” variable to let us know if we are operating • What action should the shifter take in event of alert?