Single Ended Measuring Modes of ELQ 30A+

Single Ended Measuring Modes of ELQ 30A+. Transmitting. Receiving Modes. Spectrum Analyzer. Wide Band Noise Measurement. Impulse Noise Measurement. NEXT Measurement. Micro Interruption Measurement. Single Ended Loss Measurement. Echo Test. Impedance Measurement. Return Loss Measurement.

kabney
Télécharger la présentation

Single Ended Measuring Modes of ELQ 30A+

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Single Ended Measuring Modes ofELQ 30A+ Transmitting Receiving Modes Spectrum Analyzer Wide Band Noise Measurement Impulse Noise Measurement NEXT Measurement Micro Interruption Measurement Single Ended Loss Measurement Echo Test Impedance Measurement Return Loss Measurement LCL Balance Measurement To learn more click onthe selectedtopic! ELEKTR NIKA

  2. Transmitting Modes ofELQ 30A+ ELQ 30A+ provides two transmitting modes: ■ 1 FREQ (Transmitting of one single frequency ) ■ MTTS (Transmitting 30 to 35 frequencies simultaneously) 1 FREQ mode ■Range: 200 Hz to 35 MHz ■Resolution: 1 Hz MTTS mode Selectable ranges: ELEKTR NIKA

  3. Receiving Modes ofELQ 30A+ ELQ 30A+ provides three receiving modes: ■ 1 FREQ (Measuring of one single frequency ) ■ MTTS (Measuring 30 to 35 frequencies simultaneously) ■ WIDE EBAND (Wide band measurement with selectable filters) 1 FREQ mode ■Range: 200 Hz to 35 MHz ■Resolution: 1 Hz Selectable bandwidths: MTTS mode Selectable ranges: WIDE BAND mode Selectable filters: ELEKTR NIKA

  4. Spectrum Analyser Measurement Spectrum analyser of ELQ 30A+ is intended to: ■ Noise Spectrum Measurement on Passive Lines ■ PSD Spectrum Measurement on Working Lines In this case the test instrument should be connected parallel to the line with high impedance. The digital systems are extremely sensitive for the capacitive load therefore the regular measuring cables can not be used. For line connection an optional active probe is provided: Selectable ranges: Selectable evaluation modes: ■ Normal ■ Slipping average (Average of the last 10 measurements) ■ Average ■ Peek ELEKTR NIKA

  5. Wideband Noise Measurement The impairment of communication caused by noises does not depend only on the level but also on the time distribution of noise. The proper measuring time depends on the nature of noise. In case of a quasi stationer noise 1 to 10 sec is enough. If the noise level is slowly changing, a longer measurement time provides the proper test result. When the selected measuring time >1 min then ELQ 30A+ displays the noise level in histogram Selectable filters: Selected duration ELEKTR NIKA

  6. Impulse Noise Measurement Impulse noise is a non-stationary cross talk from electromagnetic events in the vicinity of phone lines. Any burst of noise that produces a voltage exceeding the power level of the background noise by more than 12dB is declared impulse noise. An impulse is counted when the received signal exceeds a preset threshold for more than 500 ns. When the selected measuring time >30 sec then ELQ 30A+ displays the noise level in histogram Selected duration ELEKTR NIKA

  7. Near End Crosstalk (NEXT) Measurement ELQ 30A+ provides two NEXT measuring modes: ■ Measurement at one single frequency ■ Measurement in sweep mode Selectable ranges: ELEKTR NIKA

  8. Micro Interruption Measurement (Loop Back Mode) Micro interruption measurement can be performed with one ELQ 30A+ in loop back mode transmitting 1020 Hz test tone on connector L2 and receiving on connector L1 ELQ 30A+ detects the micro interruptions according to rec. ITU-T O.62. An interruption is detected when the level of the received test tone drops below a designated threshold for more than 0.6 ms. Short form information Histogram List The measuring time is adjustable between 5 min and 72 hours. ELEKTR NIKA

  9. Single Ended Loss Estimation ELQ 30A+ provides insertion loss estimation using a special FDR/TDR combination without any far end device. Single ended loss measurement can be performed if: ■ The tested loop is open ■ There is a strap on the far end of the tested pair ■ A telephone hand set is connected to the far end Selectable ranges: ELEKTR NIKA

  10. Echo Test There are several reasons for the undesirable quality degradation and the appearance of audible echoes is one of them. This kind of quality degradation is inherent in the network equipment and the enduser phone devices. For the test of the disturbing echoes ELQ 30A+ transmits short ~1020 Hz signal packets with proper amplitude shaping and measures the amplitude and the traveling time of the reflected signal. Time [s] ELQ 30A+ • Measuring ranges • ■Traveling time range: 15 to 1500 ms • ■Time resolution: 5 ms • ■Amplitude indication: down to -60dBm ELEKTR NIKA

  11. Impedance Measurement ELQ 30A+ provides impedance measurement without any external adapter Two impedance measuring modes are available: ■ Measurement at one single frequency ■ Measurement in sweep mode Frequency ranges: Impedance display range: ■ up to 20 kHz: 2000 Ohm ■ over 20kHz: 600 Ohm ELEKTR NIKA

  12. Return Loss Measurement ELQ 30A+ provides return loss measurement without any external adapter Two return loss measuring modes are available: ■ Measurement at one single frequency ■ Measurement in sweep mode Return loss factor indicates the deviation of line impedance from the nominal value. ELQ 30A+ compares the line impedance to an internal Rn normal resistor. Frequency ranges: ELEKTR NIKA

  13. Balance (LCL) Measurement ELQ 30A+ provides LCL measurement without any external adapter using the test circuit described in Rec.ITU-T O.9 Two balance measuring modes are provided: ■ Measurement with one single frequency ■ Measurement in sweep mode Frequency ranges: ELEKTR NIKA