1 / 16

Coil response inversion in Aarhus Workbench, November 2011

Coil response inversion in Aarhus Workbench, November 2011. Nikolaj Foged, and Esben Auken HydroGeophysics Group, Department of Earth Sciences, Aarhus University, Denmark. Get coil response from height altitude test. Import height altitude test data into Aarhus Workbench.

kamea
Télécharger la présentation

Coil response inversion in Aarhus Workbench, November 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Coil response inversion in Aarhus Workbench, November 2011 • Nikolaj Foged, and Esben AukenHydroGeophysics Group, Department of Earth Sciences, Aarhus University, Denmark

  2. Get coil response from height altitude test Import height altitude test data into Aarhus Workbench. Do not flip sign during import! “Process” the data. Turn off all slope and sign filters Use box average of raw data to sounding. Width ~5 min Located height altitude test by plotting GPS-altitude

  3. Get coil response from height altitude test Read of coil response on average plot for early SLM time gates Blue sounding curve plot [V/A*m4] Use shift + white arrow to display gate time and db/dt value at button of plot

  4. Get coil response from height altitude test Read of coil response on average plot for early SLM time gates Blue sounding curve plot [V/A*m4] Use shift + white arrow to display gate time and db/dt value at button of plot Create at Coil response file, *.bia Important: The coil response values from Aarhus Workbench need to be multiplied with the TX-area to get the right normalization for the bia-file ([V/A*m2]) bia-file example: Coil response,20100625.HT,[V/(m2*A)] 6.320E-06 -7.41E-06 7.320E-06 -2.37E-06 8.320E-06 -9.29E-07 9.320E-06 -3.45E-07 1.032E-05 -1.35E-07 1.132E-05 -5.49E-08

  5. High Altitude Test - First Gate Time ?

  6. Coil response inversion – SCI-setup Make sure then the early SLM gates are enabled Set “bias” inversion parameters in the SCI wizard Factor = 1.0 (parameter start value) Lateral STD: 1.05-1.1 (~5-10%) A-priori STD: ~4.(If the CR-response is relative constant for all flights, then state a tighter prior constant)

  7. Coil response inversion – SCI-setup Run the inversion in linear mode since negative responses are possible Inversion configurations / Data inversion: Lin. Else, setup at run the SCI-job as normal

  8. Geo-file updates for CR-inversion • Enable early gate time to use for CR-inversion (just read all in and the decide late which to use)0 0 !Default remove gates 1..X and Y..NGate on datasets, if 0 no gates are removed….. • Set the Primary field damping factor to 1e-50 1.6e-6 1e-5 !Use Frontgate (1=yes, 0=no),FrontGate time [s], Primary field damping factor….At damping factor of 1e-5 is ~quale to no primary field in the basic forward response. In this way the magnitude of the primary field ( the coil response) is fully control by the CR-invresion parameter. • Re-apply the geo-file

  9. Coil response inversion – Evaluation

  10. Coil response inversion – Evaluation

  11. Coil response inversion – Evaluation

  12. Coil response inversion – Evaluation

  13. Coil response inversion – Evaluation

  14. Coil response inversion – Evaluation

  15. Hints and tips Pre deleted gate stated in geo-file can be enabled by reapplying the geo-file Increase “Min number of data point per channel” to avoid to get soundings where full soundings original were disabled during processing Do not include gates where the gate opening time is before end of turn off ramp

  16. Hints and tips Delete negative data. In processing window (edit form) do: set factor to 1 for SLM Raw set y-axe to linear display only early Raw SLM gates, e.g 3 hours select gate below 0 (negative data) and disable the selected gates