An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Falcon 10 dump valve characterization Alexander Vorobiev

  2. Objective • Verify the valve characteristics (flow rate vs. pressure difference)

  3. Schematics of the bench test,option #1 To atmosphere To vacuum pump PV FLOW DP

  4. Equipment needed Available: • 1 differential pressure gage (11 psid) • 1 absolute pressure gage (3-14.5 psia) • 1 flowmeter * • 1 thermocouple • 1 Vacuum pump (will be available since Jul 8) Not available (to be manufactured): • Flanges and some other hardware * some shop work will be needed

  5. Schematics of the bench test,option #2 High pressure PH PO - atmospheric pressure FLOW DP

  6. Equipment needed, option #2 Available: • 1 differential pressure gage (11 psid) • 1 absolute pressure gage (14.5-24 psia) • 1 flowmeter * • 1 thermocouple • 1 pressure source • 1 high-pressure chamber Not available (to be manufactured): • Flanges and some other hardware * some shop work will be needed

  7. Bench tests, option #2, Cons: Can be only made in the range of pressures 1 ≤ PH/PO < 1.63 Because:overpressure level (PH-PO) not to exceed 9.2 psi* *component maintenance manual, DESCRIPTION AND OPERATION, p.1

  8. Bench tests, option #2 Flow of Conditioning Transitory 11.24 lbs/min Valve overpressure exceeds 9.2 psi in this region;option #2 Meaning of Tag on Data: Mach? Flow Rate = Dump Valve + A/C Leaks Allowable Air Supply Leak Rate = Dump Valve Rate – ECS Rate = 2* 11.2 lbs/min – 9 lbs/min = 13.4 lbs/min = 0.22 lbs/sec Idling Engines End of Opening Assume: Pbp/Pcond is pressure ratio between cabin and freestream Level

  9. Valve overpressure needs to be

  10. Valve