1 / 20

Chapter 15

Thyristors. Chapter 15. This latch is stable in either of two states. Q 1. Q 2. Off state. On state. Latch. {. Q 1. {. Q 2. The four-layer diode. p. Q 1. n. p. n. Q 2. Four-layer diode breakover. I. I H. V. V K. V B. The silicon controlled rectifier (SCR). Anode. Anode.

Télécharger la présentation

Chapter 15

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thyristors Chapter 15

  2. This latch is stable in either of two states. Q1 Q2 Off state On state Latch

  3. { Q1 { Q2 The four-layer diode p Q1 n p n Q2

  4. Four-layer diode breakover I IH V VK VB

  5. The silicon controlled rectifier (SCR) Anode Anode Anode p Q1 n p Gate Gate Gate n Q2 Cathode Cathode Cathode

  6. SCRs • The most widely used thyristors • Use gate triggering for turn-on instead of breakover triggering • Data sheets list the gate trigger voltage (VGT) and the gate trigger current (IGT) • Turn-off requires reducing the current to less than the holding current (IH)

  7. +VAA A B C D A B C D An SCR does not turn off at the end of the trigger pulse. +VAA Load

  8. Power supply Protected load SCR crowbar to protect a load from overvoltage VZ VT VGT The overvoltage that triggers the crowbar: VT = VZ + VGT

  9. Power supply Protected load Adding gain to a crowbar circuit R3 R1 R2 R4 R1 is the trigger adjust

  10. Power supply Protected load Adding an IC amplifier to a crowbar circuit 10 kW 10 kW A IC VA 10 kW VZ The circuit triggers when VA exceeds VZ.

  11. qfire Load qconduction SCR phase control vline 120 V R1 vload R2 C

  12. Load A snubber network can be used to limit the rate of voltage rise across the SCR. R1 RC snubber R2 C

  13. Bidirectional thyristors can conduct in either direction. I Four-layer diodes in reverse parallel Diac

  14. The triac is a popular bidirectional thyristor. I Gate SCRs in reverse parallel Triac

  15. Load Triac phase control vline 120 V R1 vload R2 C

  16. Protected load Triac crowbar Fuse R1 Triac 120 V R2 Diac R3 R2 is the trigger adjust

  17. The photo-SCR is triggered by light. RL RL Open gate Sensitivity adjust Maximum sensitivity

  18. A B C D A B C D The gate-controlled switch is turned off with a reverse-biased trigger. RL RG

  19. The silicon-controlled switch is a low-current device. Anode Anode gate Cathode gate Cathode Either gate can be used to trigger or open this device.

  20. Unijunction transistor (UJT) B2 B2 RE E E p V n B1 vin B1 When vin reaches the standoff voltage, the resistance between the emitter and B1 drops dramatically.