1 / 18

Onsite Status

Onsite Status. RIKEN/RBRC Itaru Nakagawa. OASys Light Source Spacer. New Spacer . Filed off screw head. Light Spot with/without the Spacer. w/o spacer. w/o spacer. 1.3m m. w / spacer. 1.1m m. w / spacer.

kateb
Télécharger la présentation

Onsite Status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Onsite Status RIKEN/RBRC Itaru Nakagawa

  2. OASys Light Source Spacer

  3. New Spacer Filed off screw head

  4. Light Spot with/without the Spacer w/o spacer w/o spacer 1.3mm w/ spacer 1.1mm w/ spacer 100 pixels shift out of 650 pixels observed in X direction. May be acceptable.

  5. OASys DAQ System Cannot check South OASys. We have to wait until all SMM to be back on beam line

  6. Thermocopules to North St-1

  7. OASys Fast Offline mk mklist.pl -> File list Fitting result Log files sum_stat.dat file i/oのlow level関数で新しいgccライブラリと非互換問題 -> fopen/freadで解決

  8. Recapacition Completed South Station-1 Gap-1

  9. HV Test • Station-1 Gap-1 are all OK. • Some trips in Station2 and 3

  10. Recap Clamp Installation

  11. Recap Clamp Installed to Gap-2

  12. Recapacitation Clamps • What do we do with coating? • Physically scrape off -> Need develop tool • Chemically remove -> Under investigation • Heat it up -> Soldering Iron • Inspection of the contact • Fiber Scope • Voltmeter

  13. Fiber Scope Small diameterf=6mm Short Focus 5 ~ 10 mm Side mirror ~54,000Yen

  14. Penetration Power of Coating クリップ型の開発史 Remove Coating Coating after installation

  15. Summary Recap Clamps • Alignment -> Spacer works OK. • Visual Check -> Fiber Scope • Contact Check -> Voltmeter new design • Conductive Rubber • Coating Removal • Re-coating after installation -> Splay type works? • Folk Type • Penetration power? • Pre-coating on recap clamp works?

  16. Remaining Tasks • Further contact test of the clamp with voltmeter. • Pre-coating the recap clamp • Diagnose OASys Camera N2 • Station-2 Terminator install • Toggle switch South St.2 ADTX -> but no power • St-1 terminator install (Mike next week) • OASys light source install (Mike next week) • South OASys check

  17. Re-run Muon Trigger South fibers • Re-run MuTR cables • South OASys Check • South St-2 Oct7 ADTX threshold test Oct 27 – 29 RBRC Review

More Related