An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The WFPC2 WF4 Anomaly John Biretta 15 Dec 2005

  2. Overview • Discovery of the Anomaly • Historical Evolution • Imaging Impacts • GO Science Impacts • Image Repair • Cause / Possible Mitigation Strategy

  3. Discovery of New Anomaly • First noticed during study of dark current trends • Anomalous low dark current for CCD WF4 on 9/23/2005 • 2 of 5 input images were blank in WF4 • Bias levels were zero in the 2 frames

  4. Low Dark Current on 9/23/2005 ??

  5. Historical Development • Earliest evidence ~ SM3B (March 2002) -- sporadic images begin appearing with bias level few DN below normal 311 DN • Late 2004 images with very low bias begin to appear • Feb. 2005 first zero bias (blank) images • Currently ~all images have low-bias and ~30% have zero bias in WF4 • Other three CCDs are OK

  6. Low Bias Zero Bias

  7. Imaging Impacts Two classes of WF4 image anomaly: Low-Bias Images • Background streaks • Corrupted photometry • Images probably fixable Zero-Bias Images • Mostly blank • Images cannot be fixed

  8. Low Bias Images • Bias level ~5 to ~290 DN • Pipeline corrects for low level, but… • Faint horizontal streaks +/- 0.5 DN • Photometry up to 70% low for faint targets at very low bias • ~1800 science images impacted so far • Images probably fixable

  9. WF4 Low Bias Image Example 8/25/2005 F439W, 700s Stripes in WF4. +/- 0.5 DN PC1 WF2 WF3

  10. Low Bias Image Example 8/25/2005 F439W, 700s Stripes along CCD rows +/- 0.5 DN

  11. Normal bias Bright pixels ~1000 DN Faint pixels ~15 DN

  12. Normal bias Bright pixels ~1000 DN Faint pixels ~15 DN

  13. Zero Bias Images • Bias level falls below A-to-D zero point • Image is mostly zero (blank) • Faint images & targets lost • Only cosmic rays, bright targets visible • Data unusable for most purposes • ~200 science images impacted so far

  14. WF4 Zero Bias Example 8/25/2005 F336W, 900s Mostly zero. Bright targets, cosmic rays. Negative imprint of cal files.

  15. Science Impact • Modest impact since most targets placed on PC1 or WF3 CCDs • Large targets / surveys needing entire field-of-view lose 1/3 of area • GOs notified via STAN, HST website, WFPC2 website, notice with APT release • ISR on WFPC2 website

  16. Science Impact (cont.) • Pending observations reviewed for risk; attempting to move observations early where possible • WF4 low-bias images probably fixable – preliminary scripts exist to fix images

  17. Repair of Low-Bias Images: Streak Removal • Iterative filtering of background very successful in removing streaks • Preliminary IRAF script being tested

  18. Before After

  19. Repair of Low-Bias Images: Photometry • Correction for non-linearity at low bias c’ = c + f(bias level) • Correction for anomalous gain c’’ = c’ / gain(bias level) • Can correct existing test data to +/-1%... • Need testing on broader range of data -- cal proposal 10772 submitted

  20. Normal bias Before correction… Bright pixels ~1000 DN Faint pixels ~15 DN

  21. Linearity correction brings all count levels to single curve….

  22. … then simple gain correction applied as function of bias level.

  23. Cause of Anomaly • Exact cause not yet known • Possibly instability / failure of signal amplifier • Bias variations appear driven by temperature peaks associated with cycling of the WFPC2 “Replacement Heater” • Tight correlation between WF4 camera head temperature and bias level suggests problem is located in WF4 camera head electronics

  24. Potential Mitigation Strategy • Reduce temperatures in WFPC2 camera heads / electronic bays by few deg C • “Replacement Heater” controlled by WFPC2 Bay 1 temp and software set points at 11 and 15 deg C • Test planned for January – reduce upper set point from 15 to 12 deg C for 24 hrs and take many internal images

  25. Mitigation Strategy (cont.) • 2nd test planned later – reduce both set points – from 11 & 15 deg C to (e.g.) 9 & 10 deg C • Seen as relatively safe. • Some potential for change in optical alignment (temp of optical bench).

  26. Anomaly Review Board • Ed Cheng (chair), Jim Ries, Renee Taylor, Lisa Mazzuca, Ben Reed, Jeff Travis, Augustyn Waczynski, Mal Niedner, Randy Kimble, Ken Carpenter (GSFC), Tom Bickler, Tom Elliot (JPL), Ed Cheung (J&T), John Bacinski (LMTO), John Biretta (STScI) • Report due end of January