1 / 15

GSFC  JPL

Laser Interferometer Space Antenna (LISA). Time-Delay Interferometry with Moving Spacecraft Arrays. Massimo Tinto Jet Propulsion Laboratory, California Institute of Technology. 8 th GWDAW, Dec. 17-20, 2003, Milwaukee, Wisconsin. GSFC  JPL.

kerri
Télécharger la présentation

GSFC  JPL

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Laser Interferometer Space Antenna (LISA) Time-Delay Interferometry with Moving Spacecraft Arrays Massimo Tinto Jet Propulsion Laboratory, California Institute of Technology 8th GWDAW, Dec. 17-20, 2003, Milwaukee, Wisconsin GSFCJPL

  2. W.M. Folkner et al., C.Q.G., 14, 1543, (1997)

  3. Unequal-arm Interferometers L3 f3(t) P.D fi = two-way phase measurements Laser L2 n0, p(t) P.D f2(t) S.V. Dhurandhar, K.R. Nayak, and J-Y. Vinet,Phys. Rev. D, 65, 102002 (2002). M. Tinto, & J.W. Armstrong, Phys. Rev. D, 59, 102003 (1999).

  4. Time-delay Interferometry 2 2* L1 • It is best to think of LISA as a closed array of six one-way delay lines between the test masses. • This approach allows us to reconstruct the unequal-arm Michelson interferometer, as well as new interferometric combinations, which offer advantages in hardware design, in robustness to failures of single links, and in redundancy of data. 3* o L3 3 L2 1 1* M. Tinto: Phys. Rev. D,53, 5354 (1996); Phys. Rev. D,58, 102001 (1998) J.W. Armstrong, F.B. Estabrook, and M. Tinto: Ap. J.,527, 814 (1999) F.B. Estabrook, M. Tinto, & J.W. Armstrong, Phys. Rev. D, 62, 042002(2000) M. Tinto, D.A. Shaddock, J. Sylvestre, & J.W. Armstrong: Phys. Rev. D 67, 122003 (2003)

  5. Unequal-arm Interferometers (Cont.) • One can actually regard X as given by the interference of two beams that propagate within the two arms of LISA, each experiencing a delay equal to (2L2 + 2L3) . • X is actually a zero-area Sagnac Interferometer, synthesized by properly combining measurements from each arm. 3 2 L2 L3 1 D.A. Shaddock, M. Tinto, F.B. Estabrook & J.W. Armstrong, Phys. Rev. D, 68, 061303 (R) (2003).

  6. Six-Pulse Data Combinations . 2 L3 a, b, g, z L1 . . 3 1 L2 -- ? ? D.A. Shaddock, M. Tinto, F.B. Estabrook & J.W. Armstrong, Phys. Rev. D, 68, 061303 (R) (2003).

  7. Eight-Pulse Data Combinations . . 2 2 (X, Y, Z) L3 L3 L1 Unequal-arm Michelson . . (P, Q, R) . . Beacon 3 1 3 1 L2 L2 . . 2 2 L3 L3 (E, F, G) (U, V, W) L1 L1 . . . . Relay Monitor 3 3 1 1 L2 L2

  8. Moving spacecraft Arrays and Clocks Synchronization • The analysis above assumed the clocks onboard the LISA S/Cs to be synchronized to each other in the frame attached to the LISA array. • In a rotating reference frame, the Sagnac effect prevents the implementation of the Einstein’s Synchronization Procedure, i.e. synchronization by transmission of electromagnetic signals(GPS is a good example of this problem!) • To account for the Sagnac effect, one introduces an hypothetical inertial reference frame, and time in this frame is the one adopted by the spacecraft clocks! • In other words, the onboard receivers have to convert time information received from Earth to time in this inertial reference frame (SSB). N. Asbby, “The Sagnac effect in the GPS System”, http://digilander.libero.it/solciclos/ M. Tinto, F.B. Estabrook, & J.W. Armstrong, gr-qc/0310017, October 6, 2003

  9. Moving spacecraft Arrays and Clocks Synchronization (Cont.) • In the SSB frame, the differences between back-forth delay times are very much larger than has been previously recognized. • The reason is in the aberration due to motion and changes of orientation in the SSB frame. • With a velocity V=30 km/s, the light-transit times of light signals in opposing directions (Li, and L’i) will differ by as much as 2VL (a few thousands km) • They will also change in time due to rotation (0.1 m/s); this however is significantly smaller than the spacecraft relative velocity (10 m/s).

  10. TDI with Moving spacecraft Arrays • The “first-generation” TDI expressions do not account for: • The Sagnac Effect • Time-dependence (velocity) of the arm lengths in the TDI expressions (the “Flex-effect”) • Both effects prevent the perfect cancellation of the laser frequency fluctuations in the “first-generation” TDI combinations. • With a laser frequency stability of 30 Hz/Hz1/2the remaining laser frequency fluctuations could be as much as 30 times larger than the secondary noise sources. D.A. Shaddock, Phys. Rev. D: to appear; gr-qc/0306125 Cornish & Hellings, Class. Quantum Grav.20 No 22 (21 November 2003) 4851-4860 D.A. Shaddock, M. Tinto, F.B. Estabrook & J.W. Armstrong, Phys. Rev. D, 68, 061303 (R) (2003).

  11. The Sagnac Effect and the Sagnac Combinations . 2 (a, b, g) L3 L1 . . • In presence of rotation, the amount of time spent by a beam to propagate clockwise is different by the time it spends to propagate counterclockwise along the same arm => (L1, L2, L3, L’1, L’2, L’3). • The Sagnac effect prevents the perfect cancellation of the laser frequency fluctuations in the existing expressions of the Sagnac combinations (a, b, g, z). • @ 10-3 Hz the laser frequency fluctuations remaining in (a, b, g, z) would be about 30 times larger than the secondary noise sources. 3 1 L2 . 2 L3 L1 . . L’1 L’3 L’2 3 1 L2 a1, a2, a3 a, b, g

  12. “Flexy” 3 2 1 D.A. Shaddock, M. Tinto, F.B. Estabrook & J.W. Armstrong, Phys. Rev. D, 68, 061303 (R) (2003).

  13. Systematic Approach • Is there a general procedure for deriving the “2nd generation” TDI combinations? • YES! M. Tinto, F.B. Estabrook, & J.W. Armstrong, gr-qc/0310017, October 6, 2003

  14. Systematic Approach (Cont.) . 2 L3 L’3 . . L’2 3 1 L2 = 0

  15. How Does the LISA Sensitivity Change? • Once the laser frequency fluctuations are removed, the corrections to the signal and the secondary noises (optical path, proof-mass, etc.), introduced by the extra delays due to the Sagnac (14 km) and flexy (~ 300 m) effects, are many orders of magnitude below the signals and secondary noises determined by the “1st generation” TDI expressions:

More Related