1 / 28

Two-photon absorption fluorescent probes

Two-photon absorption fluorescent probes. Jan Lewtak , 15.03.2011. Two-Photon Absorbing Fluorophores. Maximizing 2PA cross-section; combining three structural elements: electron-donating groups. Two-Photon Absorbing Fluorophores.

kiefer
Télécharger la présentation

Two-photon absorption fluorescent probes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Two-photon absorption fluorescent probes Jan Lewtak, 15.03.2011

  2. Two-PhotonAbsorbingFluorophores • Maximizing 2PA cross-section; combining three structural elements: • electron-donating groups

  3. Two-PhotonAbsorbingFluorophores • Maximizing 2PA cross-section; combining three structural elements: • electron-donating groups • electron-accepting groups

  4. Two-PhotonAbsorbingFluorophores • Maximizing 2PA cross-section; combining three structural elements: • electron-donating groups • electron-accepting groups • conjugated p-bridges

  5. Designing of fluorophores a) Noncentrosymmetric dipolar architecture

  6. Designing of fluorophores a) Noncentrosymmetric dipolar architecture b) Centrosymmetric quadrupolar architectures

  7. Designing of fluorophores c) Noncentrosymmetric octupolar architectures: d) 3D - structures

  8. DipolarFluorescentLabels

  9. DipolarFluorescentLabels 1 GM = 10-50cm4s/photon

  10. DipolarFluorescentLabels 1 GM = 10-50cm4s/photon Geoppert-Mayer, M. Ann. Phys. (Leipzig) 1931, 5, 273–294.

  11. Dipolar Fluorescent Labels 202 GM Schafer-Hales, K. J.; Belfield, K. D.; Yao, S.; Frederiksen, P. K.; Hales, J. M.; Kolattukudy, P. E. J. Biomed. Opt. 2005, 10(5), 015402

  12. Dipolar Fluorescent Labels 202 GM 248 GM Andrade, C. D.; Yanez, C. O.; Rodriguez, L.; Belfield, K. D. J. Org. Chem. 2010, 75(12), 3975–3982.

  13. Dipolar Fluorescent Labels 202 GM 248 GM 563 GM Andrade, C. D.; Yanez, C. O.; Rodriguez, L.; Belfield, K. D. J. Org. Chem. 2010, 75(12), 3975–3982.

  14. Dipolar Fluorescent Labels 202 GM 248 GM 563 GM 1146 GM Barsu,C.;Cheaib,R.;Chambert, S.;Queneau,Y.;Maury,O.;Cottet,D.; Wege,H.; Douady, J.; Bretonniere, Y.; Andraud, C. Org. Biomol. Chem. 2010, 8(1), 142–150. Barsu, C.; Fortrie, R.; Nowika, K.; Baldeck, P. L.; Vial, J.-C.; Barsella, A.; Fort, A.; Hissler, M.; Bretonniere, Y.; Maury, O.; Andraud, C. Chem. Commun. 2006, 45, 4744–4746.

  15. Dipolar Fluorescent Labels 202 GM 248 GM 563 GM 1146 GM

  16. Dipolar Fluorescent Labels Action cross-section - strong dependence on solvent: hd = F*d

  17. Centrosymmetric Quadrupolar Fluorophores

  18. Centrosymmetric Quadrupolar Fluorophores Centrosymmetric architectures can yield very large 2PA cross-sections Chui, C.-H.; Wang, Q.; Chow, W.-C.; Yuen,M. C.-W.; Wong, K.-L.; Kwok, W.-M.; Cheng, G. Y.-M.; Wong, R. S.-M.; Tong, S.-W.; Chan, K.-W.; Lau, F.-Y.; Lai, P. B.-S.; Lam, K.-H.; Fabbri, E.; Tao, X.-M.; Gambari, R.; Wong, W.-Y. Chem. Commun. 2010, 46(20), 3538–3540. Albota,M.A.;Xu,C.;Webb,W.W. Appl.Opt. 1998, 37(31), 7352–7356.

  19. Centrosymmetric Quadrupolar Fluorophores Planarity matters 160 GM, inflexible 110 GM, conformational freedom Oligoethyleneglycol chains… Hayek, A.; Bolze, F.;Nicoud, J. F.; Baldeck, P. L.;Mely,Y. Photochem. Photobiol. Sci. 2006, 5(1), 102–106. Hayek, A.; Grichine, A.; Huault, T.; Ricard, C.; Bolze, F.; van der Sanden, B.; Vial, J. C.;Mely, Y.; Duperray, A.; Baldeck, P. L.; Nicoud, J. F. Microsc. Res. Techn. 2007, 70(10), 880–885.

  20. Centrosymmetric Quadrupolar Fluorophores 314 GM Sensitizer for Boron Neutron Capture Theraphy (BNCT). Fluorescence lifetime imaging 335GM 1090 GM Alkynyl spacers Hayek, A.; Bolze, F.; Bourgogne, C.; Baldeck, P. L.; Didier, P.; Arntz, Y.; Mely, Y.; Nicoud, J. F. Inorg. Chem. 2009, 48(19), 9112–9119. Hawthorne, M. F. Angew. Chem., Int. Ed. 1993, 32(7), 950–984.

  21. Octupolar architecture Strongly red-shifted emisson spectrum after Zn-polarization Bhaskar, A.; Ramakrishna, G.; Twieg, R. J.; Goodson, T. J. Phys.Chem. C 2007, 111(40), 14607–14611

  22. Metal Complexes – 3D structures 214 GM 530 GM 3-fold increase compared to free ligands 10000 GM Das, S.; Nag, A.; Goswami, D.; Bharadwaj, P. K. J. Am. Chem. Soc. 2006, 128(2), 402–403. Kamada, K.;Matsunaga, K.; Yoshino, A.; Ohta, K. J. Opt. Soc. Am. B 2003, 20(3), 529–537. Zhang, X.-B.; Feng, J.-K.; Ren, A.-M. J. Organomet. Chem. 2007 692(17), 3778–3787. Mazzucato, S.; Fortunati, I.; Scolaro, S.; Zerbetto, M.; Ferrante, C.;Signorini, R.; Pedron, D.; Bozio, R.; Locatelli, D.; Righetto, S.; Roberto, D.; Ugo, R.; Abbotto, A.; Archetti, G.; Beverina, L.; Ghezzi, S. Phys. Chem. Chem. Phys. 2007, 9(23), 2999–3005.

  23. Metal Complexes – 3D structures Tridentate ligand – Zn(II) Terpyridine 2600 GM 2730 GM From 96 to 186 GM Ray, D.; Nag, A.; Goswami, D.; Bharadwaj, P. K. J. Lumin. 2009, 129 (3), 256–262.

  24. Metal Complexes – 3D structures Water-soluble Eu complex, 92GM, 700nm Two-photon excited luminescence image of cancer cells loaded with complex shown above Picot, A.; D’Aleo, A.; Baldeck, P. L.; Grichine, A.; Duperray, A.; Andraud, C.; Maury, O. J. Am. Chem. Soc. 2008, 130(5), 1532–1533

  25. Metal-ResponsiveFluorescentProbes While Mg(II) saturation 2150 GM – 45GM 1800 GM – 300GM Two-photon absorbing indicators Pond, S. J. K.; Tsutsumi, O.; Rumi, M.; Kwon, O.; Zojer, E.; Bredas, J.-L.; Marder, S. R.; Perry, J. W. J. Am. Chem. Soc. 2004, 126(30), 9291–9306.

  26. Metal-ResponsiveFluorescentProbes Hg(II)-responsive indicator Complete fluorescence quenching Huang, C. B.; Fan, J. L.; Peng, X. J.; Lin, Z. Y.; Guo, B. P.; Ren, A. X.; Cui, J. Q.; Sun, S. G. J. Photochem. Photobiol. 2008, 199(2-3), 144–149.

  27. Metal-ResponsiveFluorescentProbes Hg(II)-responsive indicator Complete fluorescence quenching Calix[4]arene-based indicator Kim, J. S.; Kim, H. J.; Kim, H. M.; Kim, S. H.; Lee, J. W.; Kim, S. K. Cho, B. R. J. Org. Chem. 2006, 71(21), 8016–8022.

  28. Summary • building desired structure • detection metal ions – selective and sensitive • applications, i.e. TPEM (two-photon excitation microscopy)

More Related