1 / 8

"PV11R" SERIES PV11R10-10Pub. EC-0119

"PV11R" SERIES PV11R10-10Pub. EC-0119. Up to 40 MPa (5800 PSI), 22.1 cm3 /rev (1.349 CU.IN./rev). Gambar vane pump PV11R secara utuh. Maximum Operating Pressure MPa(PSI). Geometric Displacement cm3 /rev (CU.IN./rev):9.7(.592)

kinsey
Télécharger la présentation

"PV11R" SERIES PV11R10-10Pub. EC-0119

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. "PV11R" SERIESPV11R10-10Pub. EC-0119 Up to 40 MPa (5800 PSI), 22.1 cm3 /rev (1.349 CU.IN./rev)

  2. Gambar vane pump PV11R secara utuh

  3. Maximum Operating Pressure MPa(PSI) • Geometric Displacement cm3 /rev (CU.IN./rev):9.7(.592) • Petroleum Base Oils Anti-Wear Type 40 (5800) dan R & O Type 25 (3630) Petroleum Base Oils

  4. Typical Pump Characteristic described on the Pages below 5 , 6 • Berat flange 16.4 kg dan berat foot 19,4 kg • Kecepatan putar vane ump adalah antara 950-2300 Rpm

  5. Instructions • Alignment of shaft : Employ a flexible coupling whenever possible, and avoid any stress from bending or thrust. Maximum permissible misalignment is less than 0.1 mm (.004 inches) TIR and maximum permissible misangular is less than 0.2°.

  6. Suction pressures • Set the suction pressure at pump inlet port at the value given in the table below. Furthermore, use the pipes in the suction side having the diameter as indicated on the installation drawings. In case where the pump is installed on the tank or at the position higher than the tank top cover, the height of the suction port of the pump should be less than 1 metre (3.3 ft.) from the oil level {less than 0.8 metre (2.6 ft.) in case of using phosphate ester fluids or water containing fluids}.

  7. Precautions at starting • At an initial operation or at an operation after a long rest, the pump may have difficulty in sucking up fluid. In such cases, an air bleed valve should be installed beforehand on the discharge side (model No. ST1004-∗-10∗, Catalogue No. Pub. EC-3001.), or discharge air by slightly slackening the connection on the discharge side. At starting, operate the pump intermittently as far as possible with no load. For fluid viscosity at starting, see the item of "Hydraulic Fluids".

  8. Other precautions • If a PV11R series single pump is used at speed below 1200 r/min, install the pump with the suction port upside so that the pump can suck up fluid easily at starting.

More Related