1 / 33

Presenting Numerical Values from an Investigation

Presenting Numerical Values from an Investigation. Version 080104. Outline. Uncertainty Propagation of Uncertainty Least Squares Fit to Lines. Online References. www.av8n.com/physics/uncertainty.htm mathworld.wolfram.com/LeastSquaresFitting.html www.physics.csulb.edu/151lab/exp4/lsf.html.

krysta
Télécharger la présentation

Presenting Numerical Values from an Investigation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Presenting Numerical Values from an Investigation Version 080104

  2. Outline • Uncertainty • Propagation of Uncertainty • Least Squares Fit to Lines

  3. Online References • www.av8n.com/physics/uncertainty.htm • mathworld.wolfram.com/LeastSquaresFitting.html • www.physics.csulb.edu/151lab/exp4/lsf.html

  4. Which is the best measurement?Which measurement is consistent with the previously published result? • 6.63 E-34 Js • 6.7 E-34 Js • 6.623 E-34 Js

  5. Which is the best measurement?Which measurement is consistent with the previously published result? • 6.613 ±0.003 E-34 Js • 6.7 ±0.2 E-34 Js • 6.622±0.001 E-34 Js

  6. UNCERTAINTY

  7. Uncertainty CJ’s bad karma Best Power Supply money can buy 30 yr old piece of precision equipment Best measurements that can be performed Voltage stabilization circuit built by Floyd Vibrations from Levi Center construction

  8. Cumulative Set of Measurementsby Lab Unit #1 # of Occurances

  9. Cumulative Set of Measurementsby Lab Unit #2 # of Occurances should report center and width of distribution

  10. 45±1 45±2 may look like numbers, but they’re not.It’s a way to specify a probability distribution

  11. Relative Uncertainty An experiment measures the value of the fundamental charge to be: (1.84 ± 0.09) x 10-19 Coulombs or 1.14 ± 0.06 e

  12. SignificantFigures

  13. Sig Figs are for Losers “Non-experts tend to talk about ‘significant digits’, but this approach is heavily flawed. Professionals general prefer to speak in terms of quantifying the uncertainty.”

  14. Why Sig Fig approach is bad An experiment measures the value of the fundamental charge to be: 1.1 e 1.149 1.050 10% rel unc. is implied Sig Fig approach: 1) misrepresents the true uncertainty (actually the uncertainty is not specified) 2) throws away information 3) can produce erroneous results (see linear fits) Physicists present a ‘reasonable number’ of digits in published work, but many more digits in calculations.

  15. Example Calculational tools for an investigation return the result: 1.64578359 ± 0.05385672 meters Q: In a professional paper this should be presented as (?): 1.6458 ± 0.0539 meters 1.646 ± 0.054 meters 1.65 ± 0.05 meters 1.6 ± 0.1 meters

  16. Notation • 1.646 ± 0.054 meters • 1.646 (54) meters • 1.646 ± 3% meters preferred for written work preferred for conversation

  17. If you have something worth saying, don’t say it in terms of sig figs.

  18. Types of Uncertainty • Statistical • Systematic

  19. What is the “Correct” Answer? • “In classroom settings, people often get the idea that the goal is to report an uncertainty that reflects the difference between the measured value and the ‘correct’ value.” • “That idea certainly doesn’t work in real life – if you knew the ‘correct’ value you wouldn’t need to make measurements.”

  20. PROPAGATION OF UNCERTAINTY

  21. ?

  22. LEAST SQUARES FITTING Figures and equations from: mathworld.wolfram.com/LeastSquaresFitting.html

  23. y = a0 + a1 x + a2 x2 + … The Excel “trendline” function isn’t good enough. One must always present uncertainties to be a member of the physics community. Use “linest” to get the parameters and their corresponding uncertainities. Use “trendline” to draw the graph.

  24. Two possible ways to select the best line:

  25. Minimize square-deviation wrt choice of coefficients assume linear fn

  26. intercept a = slope b =

  27. Using the Excel function LINEST Slope = INDEX(LINEST(y-values,x-values,TRUE,TRUE),1,1) Uncertainty in Slope = INDEX(LINEST(y-values,x-values,TRUE,TRUE),2,1) Intercept = INDEX(LINEST(y-values,x-values,TRUE,TRUE),1,2) Uncertainty in Intercept = INDEX(LINEST(y-values,x-values,TRUE,TRUE),2,2)

More Related