E n v i r o n m e n t

E n v i r o n m e n t. Interference. + D y. + D x. 2. Matching. Matching. Influence. Influence. 5. SOURCES OF ERRORS. 5. SOURCES OF ERRORS. Measuring errors can occur due to the undesirable interaction between the measurement system and:. the object under test,.

levi
Télécharger la présentation

E n v i r o n m e n t

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. E n v i r o n m e n t Interference +Dy +Dx 2 Matching Matching Influence Influence 5. SOURCES OF ERRORS 5. SOURCES OF ERRORS • Measuring errors can occur due to the undesirable interaction between the measurement system and: • the object under test, • the environment, • observer. x y 1 Measurement Object Measurement System Observer

  2. Anenergetic matching is usually used in active measurement systems, which do possess internal power amplification. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.1. Anenergetic matching 5.1. Influencing the measurement object: matching 5.1.1. Anenergetic matching Anenergetic matching is used to minimize the transfer of energy between the measurement object and the measurements system. After matching, measurement will not supply any appreciable energy to, or receive from the measurement object. Reference: [1]

  3. Rmsr>> Rs Vmsr Vin; the power supplied by the object is small; most part of it is dissipated inRmsr. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.1. Anenergetic matching Example: Anenergetic matching Measurement object Measurement system Rs Vin Vmsr Rmsr Measurement object Measurement system Rmsr<< Rs Imsr Iin; the power supplied by the object is small; most part of it is dissipated inRmsr. Imsr Rs Iin Rin

  4. Anenergetic matching is especially important for passive measurement systems, which do not possess internal power amplification. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.2. Energic matching 5.1.2. Energic matching The aim of energic matching is to extract the maximum available power from the measurement object, so that the required power gain in the measurements system can be as small as possible. Reference: [1]

  5. Vs2Rmsr (Rs+ Rmsr)2+ (Xs+Xmsr)2 Pavg = I2 Rin = . 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.2. Energic matching To optimize the energic matching, let us consider the following equivalent circuits of the measurement object and the measurement system. Measurement object Measurement system Zs=Rs + Xs Zmsr=Rmsr+ Xmsr Vin Vmsr The average power delivered to the measurement system can be found as:

  6. Therefore, the maximum power a measurement object can deliver to a measurement system is: Vs2 Vs2 Pavg = = . 4Rmsr 4Rs 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.2. Energic matching For a givenRo, this power is maximal if the following optimal matching is obtained: Rmsr= Rs andXmsr = - Xs or Zmsr= Zs*. Reference: [1]

  7. The maximum power a measurement object can deliver to a measurement system is in this case: Vs2 Pavg = . 2Rmsr 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.2. Energic matching If Ro can be adjusted, then the optimal matching is obtained when Ro = 0 andXmsr = - Xo . Reference: [1]

  8. For this reason, the measurement systems almost always used are active systems (with built-in power gain). NB: The maximum power matching usually causes greater measurement errors, since the input and output impedances of the chain affect the measurement. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.2. Energic matching Available power is defined as the maximum power that can be delivered to a load from a source having fixed nonzero resistance Vin2 Pa  Pavg = . 4Ro Ro0 Reference: [1]

  9. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.3. Non-reflective matching 5.1.3. Non-reflective matching Non-reflective or characteristic matching is used for transporting high-frequency measurement signals along transmission lines. If a transmission line is not terminated characteristically, reflections off the ends of the line will cause standing waves on the line; the line output signal is no longer a good measure for the line input signal. The characteristic impedance, Z0, of a transmission line equals its input impedance if if the transmission line length were infinite. For a lossless transmission line with the series inductance per meter L and the parallel capacitance per meter C,  L Z0= = R0. C Reference: [1]

  10. NB: When Ro= R0= Rmsr holds, energic matching is also achieved simultaneously, since Ro= Rmsr. R0 is an apparent resistance that does not dissipate energy; half of the energy delivered by Vin is dissipated in Ro and the other half in Rmsr. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.3. Non-reflective matching Illustration: Non-reflective matching: Ro= R0= Rin Measurement object Measurement system Z0 Z0 Rs Vin Rmsr Vmsr=0.5Vin Reference: [1]

  11. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.3. Non-reflective matching Example: The characteristic impedances of different connections Type of connection Characteristic impedance DEFINITION Coaxial cable 50 - 75 W Printed circuit board traces 50 - 150 W Twisted wire pairs 100 - 120 W Ribbon cable 200 - 300 W Free space 376 W Reference: [1]

  12. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.4. When to match and when not? 5.1.5. When to match and when not? • Do match by adjusting impedances, by adding voltage buffers or by adding matching transformers: • To transfer maximum power to the load. The source must be capable. • To minimise reflections from the load. Important in audio, fast (high frequency) systems, to avoid ringing or multiple pulses (e.g. in counting systems). • To transmit fast pulses. Pulse properties can contain important information. • Note that the same physics is encountered in other areas, e.g. optical coatings, gel in ultrasound scans, optical grease, etc. Reference: www.hep.ph.ic.ac.uk/Instrumentation/

  13. 5. SOURCES OF ERRORS. 5.1. Influencing the measurement object: matching. 5.1.4. When to match and when not? • Do not match: • High impedance source with small current signals. Typical for many photodiode sensors, or other sensors that must drive high impedance load. Short cables are required to avoid difficulties. • Weak voltage source. Drawing power from source would affect the result, e.g. bridge circuits. • If you need to change properties of a fast pulse, e.g. pulse widening for ease of detection. • Electronics with limited drive capabilities, e.g. logic circuits, many are designed to drive other logic, not long lines, CMOS circuits, even with follower, are an example. Reference: www.hep.ph.ic.ac.uk/Instrumentation/