1 / 20

Models for Axial Loading of Murine Long Bones

Models for Axial Loading of Murine Long Bones. K. Alice Matthews Jonathon Gali Kellen Sakala Advisors: Dr. Jeffrey Nyman and Dr. Daniel Perrien. Motivation.

lilka
Télécharger la présentation

Models for Axial Loading of Murine Long Bones

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Models for Axial Loading of Murine Long Bones K. Alice Matthews Jonathon Gali KellenSakala Advisors: Dr. Jeffrey Nyman and Dr. Daniel Perrien

  2. Motivation • Mechanosensitivity of bone is lost with osteoporosis, and understanding the signaling that leads to bone adaptation while under mechanical loading can lead to insight into new targets for therapy. • Bone fractures are costly, but understanding the structural strength of the femoral neck in normal and diseased mice can lead to providing insight into its role in osteoporotic fractures

  3. Statistics • Osteoporosis affects approximately 75 million people in Europe, USA, and Japan • 1 in 3 women over the age of 50 will experience osteoporotic fractures as will 1 in 5 men • Exercise has been proven to reduce the risk of osteoporosis , fracture, and fall-related injuries • In the US in 2005, there were 2 million fractures caused by osteoporosis which cost $17 billion

  4. Objectives • Design a dynamic tibial-loading system for mice • Will aid in studying consequences of deleting the Sirtuin-1gene in osteocytes. • Sirtuinproteins may play a key role in an organism's response to stress. • Recent studies show they are involved in age related diseases such as osteoporosis. • Design a potting apparatus for loading a murine femur to test femoral neck strength in mice suffering from Perthes disease, a form of osteonecrosis that occurs in the hip.

  5. Problem to Address-Tibia How to design testing fixtures that will allow us to mechanically load a very small bone in a physiological manner Normal loading while walking is 200-600μ, but μ >1200 needed to stimulate osteogenesis

  6. Solutions-Tibia • Manufacture and calibrate an apparatus for dynamic axial loading of tibia of live mice. Patella resting in top cup and Calconeum in bottom cup with groove for foot Live mouse on its back

  7. Performance Criteria Tibia Study • Tibial loading cups should provide support during testing and effectively minimize injury/discomfort to mouse. • Effectively transfers mechanical load to murine tibia, causing desired peak tibial strain (1500 μ) in order to examine the effects of Sirtuin-1 on bone growth and bone remodeling. Lanyon, 2008

  8. Current Progress-Tibia • Created protocol in Instron control software and performing 3 week test on ex-vivo tibia • Fifty trapezoidal wave cycles every 11.5 seconds for ten minutes. • Loading time 1.5 seconds loading from1N to 9N • 1500 microstrain (optimal strain for bone growth )

  9. Current Progress-Tibia • Subjected 7 mice to mechanical loading on tibia three times a week • 4 KO and 3 Wildtype • 2% Isoflorane 98% O2 • Sacrificed the 7 mice and excised the femur, tibia, and spine of each mouse. • Collected blood samples and prepared the OB and OCL cultures and histology • Our design is currently being used in an additional study

  10. Future Work-Tibia • Have histological tests done on the excised bones • Conduct OB and OCL culture tests • Examine the response to mechanical loading measured by microCT, finite element modeling, and histomorphometric analysis of metaphysealtrabecular and diaphyseal cortical bone • Analyze data and determine whether SIRT1 affects the response to mechanical loading and subsequent bone growth of the tibia

  11. Loading Comparison Force will be applied at constant speed until failure (femoral neck fracture). This differs from the loading done in the live mice study where a non-failure force was applied and then released 50 times (to tibia).

  12. Problems to Address-Femoral Head • Need to be able to test multiple femurs in same orientation • Apparatus will allow the bone to be scanned by micro-computed tomography so that boundary conditions of biomechanical test can be simulated in uCT finite element modeling of femoral neck loading • Couple uCT-FEM predictions with experimental measurements to show how gene affects material properties of bone

  13. Performance Criteria Femur Potting Apparatus • Potted murine femur capable of being transitioned from loading apparatus to micro-ct tube for imaging and subsequent finite element modeling and analysis.

  14. Solutions-Femoral Head • Design of a potting apparatus for testing of multiple femurs in the same orientation that can then be scanned with micro-Ct Square Block: 1.5 cm X 1.5 cm X 0.5 cm Micro-CT Insertion Tube: 0.39 cm outer diameter, 0.27 cm inner diameter, 0.37 cm tall Load Cell Attachment Tube: 1 cm diameter, 0.75 cm tall Jamisa, 1998

  15. Drawbacks to SolidWorks Design • Cost • Time • Materials Available • Skills needed to produce the potting apparatus • Conclusion: SolidWorks Design has been abandoned at this point for a new approach

  16. New Solution – Microcentrifuge tubes • Reasons Why: • Easily available and plentiful in the biomechanics lab. • Can be easily loaded into the Instron machine. • Tube can be cut to fit into microCT scanning tubes • Easily place bone into potting mixture in tube

  17. Tweezer Clamps vs. 3-point Loading Arm • 3 point loading arm • Pros: Reduces error (3-point hold, angle adjustment), bone protection • Cons: Delicate • Tweezer clamp • Pros: Stronger hold • Cons: Less control of potting angle

  18. Decision: 3-Point Loading Arm

  19. Future Work Femur Potting Apparatus Timeline • Week of March 21: pot test bones • Week of March 28: load test bones, perform microCT • Week of April 4: analyze results/process, deliver protocol for bones of interest • Week of April 11: complete project

  20. References • Jamsa T et al. Femoral neck strength of mouse in two loading configurations: Method evaluation and fracture characteristics. Journal of Biomechanics, April 1998. • Leanne Kaye Saxon and Lance Edward Lanyon. Methods in Molecular Biology, Chapter 21: Assessment of the In Vivo Adaptive Response to Mechanical Loading. May 2008 • Jamsa T et al. Femoral Neck Is a Sensitive Indicator of Bone Loss in Immobilized Hind Limb of Mouse. Journal of Bone and Mineral Research, November 1999. • Willinghamm et al. Age-related changes in bone structure and strength in female and male BALB/c mice. Calcified Tissue International, June 2010

More Related