1 / 8

Radiation measurement and comparison between VT/CM tests at KEK-STF

Radiation measurement and comparison between VT/CM tests at KEK-STF. Kirk. Radiation Detector in KEK-STF. There are two types of detectors, MAR-781 and MAR-782. Specifications: Radiation detected: X-ray and γ -ray Detector type: Silicon semiconductor Energy range: 50 keV to 6 MeV

loyal
Télécharger la présentation

Radiation measurement and comparison between VT/CM tests at KEK-STF

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Radiation measurement and comparison between VT/CM tests at KEK-STF Kirk TTC Meeting 2014@DESY

  2. Radiation Detector in KEK-STF There are two types of detectors, MAR-781 and MAR-782. Specifications: Radiation detected: X-ray and γ-ray Detector type: Silicon semiconductor Energy range: 50 keV to 6 MeV Measurement range: 0.1-999.9μSv/h 0.001-99.99mSv/h Accuracy: within ±10% These detectors are used in VT and CT. But, each position is different. http://www.hitachi-aloka.co.jp/english/products/data/radiation-011-MAR781782 TTC Meeting 2014@DESY

  3. Detector position in VT area Cavity position is 4m below from top plate of cryostat. ① Center of Beam Axis ~80cm ~100cm ③ Floor of pit ② Floor of pit TTC Meeting 2014@DESY

  4. Detector position in VT area Cavity position is 4m below from top plate of cryostat. ① Center of Beam Axis ~80cm ~100cm Radiation level depends on material kind and thickness, and distance from a cavity. Representatively, we use “On beam axis” position. ③ Floor of pit ② Floor of pit TTC Meeting 2014@DESY

  5. Detector position in CT area “S1-Global” cryomodule Set positions of radiation detector There is “No” detector on beam axis in CT! TTC Meeting 2014@DESY

  6. Comparison of cavity performance Cryomodule - C Cryomodule - A Degradation of Eacc,max Tuner Trouble Coupler Vacuum Tuner Trouble C1 C2 C3 C4 A1 A2 A3 A4 U X-ray M X-ray D X-ray Up-stream Down-stream TTC Meeting 2014@DESY E. Kako

  7. Comparison of cavity performance Degradation of Eacc,max A1 A2 C1 C2 at 25MV/m A3 C4 A4 C3 at 25MV/m TTC Meeting 2014@DESY E. Kako

  8. Conclusion • There is no simple comparison of radiation level • between VT and CT in KEK-STF. • Different location • On axis/Off axis, distance from cavity • Different material and thickness • Cryostat design/material, different thickness • Different operation mode (CW/pulse) • Dependence on time response/accuracy of radiation detector TTC Meeting 2014@DESY

More Related