Heidi M. Sosik Robert J. Olson

Plankton Analysis by Automated Submersible Imaging-in-Flow Cytometry: Transforming a Specialized Research Instrument into a Broadly Accessible Tool. Heidi M. Sosik Robert J. Olson. Flow Cytometry in the Lab. Flow Cytometry in situ. Microphytoplankton. Picophytoplankton.

marrim
Télécharger la présentation

Heidi M. Sosik Robert J. Olson

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Plankton Analysis by Automated Submersible Imaging-in-Flow Cytometry:Transforming a Specialized Research Instrument into a Broadly Accessible Tool Heidi M. Sosik Robert J. Olson

  2. Flow Cytometry in the Lab Flow Cytometry in situ Microphytoplankton Picophytoplankton Long-term goal and strategy • Understand regulation of seasonal to interannual plankton dynamics • Time series observations are key • New sampling and analysis systems must be developed

  3. 2008 NOPP-funded project “Sensors for Measurement of Biological, Bio-Optical or Chemical Properties of the Ocean” Topic Three-way partnership Woods Hole Oceanographic Institution University of Washington Cytopeia, Inc. Two main objectives • Transition of Imaging FlowCytobot to commercially viable status Promote access for the broader oceanographic and environmental monitoring communities  User-tested pre-commercial units • Extending Imaging FlowCytobot’s target size range Enhance the technology for a next generation instrument  Research prototype

  4. Overview • Imaging FlowCytobot • Description, readiness, motivation for commercialization • Why should this community be interested? • Partnerships • Cytopeia • University of Washington • Proposed work • Iterative design optimization strategy • Target subsystems • Current Status

  5. FlowCytobot Principals from conventional flow cytometry (but automated and submersible) Optimized for “small” cells (~1-15 mm) Olson et al. 2003 Imaging FlowCytobot Derived from FlowCytobot design Optimized for large cells (~10-300 mm) Olson and Sosik 2007 • Automated features for extended deployment • Standard analysis • Biofouling control • Realtime humidity sensing & intake valve control 6-month deployments routine

  6. Imaging FlowCytobot Data example Nano/microplankton -Associated images (all same scale) Chl fluoresence Light scattering Individual particle measurements

  7. Martha’s Vineyard Coastal Observatory Remote sensing Air-side observations SeaPRISM shortwave radiation, winds, etc. In water observations T,S, currents, fluorescence, backscattering, oxygen, flow cytometry and cell imaging Bottle samples chlorophyll, absorption, etc. • Operational since 2001 • 24/7 power and data • Open to new users • Realtime public data access

  8. The Phytoplankton Community at MVCO Imaging FlowCytobot Microplankton FlowCytobot Picoplankton

  9. Picoplankton to Microplankton event to seasonal to interannual scales Diatoms Which ones are diatoms? > 130 million images to date

  10. 50 mm Automated image analysis and classification 22 categories (16 phytoplankton genera) 88% overall accuracy Image processing Supervised machine learning algorithm Statistical error correction Sosik and Olson 2007

  11. Major contributors: 6 Diatom taxa Taxonomic resolution winter / spring 2007 2007 Total for all images January – July

  12. Seasonality in phytoplankton biomass – Two views Extracted pigment analysis • Chl • fall / winter peaks • diatom blooms … Carbon budget cell image / scattering ↓ cell volume ↓ cell carbon ∑(C cell-1) Flow cytometry

  13. Biomass and community structure How is this C distributed across size classes? Microplankton fall / winter Picoplankton summer Nanoplankton all year

  14. Biomass and community structure HPLC-based (Vidussi et al. approach) Proportion pico v. micro + nano How does this result compare to other methods?

  15. Biomass and community structure HPLC-based (Vidussi et al. approach) Proportion nano … How does this result compare to other methods?

  16. Texas Coast Winter 2008 - First ever DSP event Auto * Manual Port Aransas, TX Imaging FlowCytobot 3 – The early warning! Shellfish recalled & harvest closed within days Olson, Sosik & Campbell

  17. Partnerships University of Washington • Development of position sensitive detector (PSD) Cytopeia, Inc. • Influx – high speed cell sorter, open architecture • Large bio-medical market ($9M in 2007 sales) • Specialized Influx Mariner for oceanographic users • Contributing engineering and fabrication at no cost Founder Ger van den Engh Experienced R&D team

  18. Evaluation by outside users ~ ~ Commercial units Commercial Transition Design Optimization WHOI / Cytopeia Iterative process Build on strengths at WHOI & Cytopeia Leverage MVCO access and existing research prototypes Expand to select outside users Evaluation at WHOI / MVCO

  19. Design optimization targets • Opto-mechanical system • Fixed modules for stability • Fluidics system • Custom syringe pump to reduce size and power • Illumination for imaging • LEDs to replace Xenon strobe • Signal detection • Improved electronics, digital signal processing • Control system • Integration • Control software • Integration and user-friendliness

  20. Current Status Opto-mechanical components Existing collection of off-the-shelf components to be replaced by Cytopeia’s custom rigid assembly Model 1 Design complete Fabrication complete Under evaluation at WHOI Cytopeia’s rigid fixed assembly detector module Imaging FlowCytobot fluidics and optics

  21. Current Status Fluidics system Existing off-the-shelf HPLC syringe pump to be replaced by Custom unit, modified from MBARI design Model 1 Design acquired Fabrication complete Under evaluation at WHOI  20% reduction in overall power consumption custom syringe pump

  22. Imaging FlowCytobot – commercial transition Applications Ecological research HAB warning PFT algorithms / validation Cell size class algorithms / validation Carbon budgets Design goals Increase ease of manufacture & use Reduce size, power consumption Expand dynamic range Adapt analysis methods THANK YOU!