1 / 56

Presentation…

Hydronics Ltd. Family of Products. Family of Products. Presentation…. CAMUS Hydronics is a world renowned manufacturer of Industrial, Commercial and Residential Boilers and Water Heaters. .

mercer
Télécharger la présentation

Presentation…

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hydronics Ltd. Family of Products Family of Products Presentation…

  2. CAMUS Hydronics is a world renowned manufacturer of Industrial,Commercial and ResidentialBoilers and Water Heaters. The CAMUS corporate head office,manufacturing plant and warehouseare housed under one roof in amodern 68,000 square foot facility.

  3. CAMUS products are constructedusing state of the art componentsand high quality materials, engineeredto operate with maximum efficiency,providing years of dependable service. The CAMUS Product Development Teamis comprised of the very best engineersand hydronic specialists in the industry, continually setting higher standardswith every new product release.

  4. The CAMUS CERTIFIED Sealassures you thatRELIABILITYEFFICIENCYandSERVICEABILITYare built into every unit.

  5. CAMUS Hydronics is also a manufacturerof replacement parts formost copper finned water heatersand heating boilers as well as asupplier of specialty HVAC products. The CAMUS SERVICE LINEis open 24 hours a day7 days a week!

  6. THE DYNAFLAME ISAVAILABLE IN CONDENSING,NON-CONDENSING AND NEAR-CONDENSING MODELS WITH CAPACITIES RANGING FROM500 UP TO 5,000 MBUTH! Extremely Low NOx! Gas Fired Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

  7. Standard Features 85% Efficiency (non-condensing) & 95% (condensing) Suitable for Category 1 Installation All Bronze and Copper Water Surfaces Range of Burner Modulation of 20 – 100% (condensing) Range of Burner Modulation of 35 - 100% (non-condensing) Single Point Input Adjustment for Controlling Air and Gas 1 to 1 Gas/Air Ratio for perfect modulation throughout Extremely low NOx Emissions Exceeding Air Quality Standards (less than 10 PPM) Flow Switch

  8. Standard Features (continued) Very Small Footprint Extremely Low Noise Level of Operation Metal Fiber Knit Burner Stainless Steel Outer Jacket & Combustion Chamber Advanced Digital Control System with Pin Point Accuracy Proven Hot Surface Ignition w/Soft Start for Rumble Free Operation Designed for Easy Access to Components for Maximum Serviceability Gasket-less Heat Exchanger Design

  9. Standard Features (continued) Inspected and Tested to ASME Requirements Maximum Allowable Working Pressure of 160 PSI Maximum Operating Water temperature of 250°F 24 volt Circuit Breaker Protective Air Filter Very low Gas Pressure Operation (down to 2” pressure inlet) Main Burner Test Firing Valve Temperature and Pressure Gauge Pressure Relief Valve

  10. Optional Equipment Secondary Exchanger for Condensing Operation at 95% Efficiency High Gas Pressure Switch Low Gas Pressure Switch Normally Open Vent Valve Low Water Cut-Off Flame Failure Alarm Pump Delay Outdoor Installation Cupro Nickel Heat Exchanger (standard on models 3500 and up)

  11. Cross Sectionals

  12. Control Panel Advanced digital display control w/pin point accuracy Multi point diagnostic light package allowing for Simple troubleshooting Three pre-set modes of operation: Mode 1 for heating, Mode 2 for domestic hot water heating and Mode 3 for Operation by a remote controller Adjustable pump delay feature based on a Temp., difference between inlet and outlet temperatures. Displays inlet temperature, outlet temperature, temperature rise, error messages and run time Flame failure signal Optional tank mounted sensor used in conjunction with inlet sensor for domestic hot water application Many more built-in features

  13. Venting

  14. Venting

  15. Specifications DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE Heat Exchanger Head Loss & Flow Recovery Capacities MBTU Input and Output Dimensional Specifications Shipping Weights www.camus-hydronics.com www.camus-hydronics.com

  16. For Hydronic Heating – Models MFH60, 100, 150, 200, 250, 300, 400, 500, 600 For Hot Water Supply – Models MFW60, 100, 150, 200, 250, 300, 400, 500, 600 Gas Fired Residential / Light Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

  17. Performance Highlights Low NOx Up to 85% Efficiency – Non-Condensing Mode Up to 95% Efficiency – Condensing Mode Durable Ceramic Burner Unaffected by High Temperatures Vents up to 60 Feet Horizontally with 50 Feet of Air Intake Duct Suitable for Use in Negative Pressure Environments Input Range From 60 to 600 MBTUH Complete Diagnostic Light Package Easy Access for Inspection and Cleaning of Heat Exchanger Tubes Simple to Service With Easy Access to Burner and Fan Durable Ceramic Fiber Refractory

  18. Control Panel Accurate Proportional Control W/2-Stage Option Incorporates Auto Reset High Limit and Operator Three Modes of Operation: Heating, DHW & Remote Port for Optional Tank Sensor * The Smartflame 780007 Control Panel Optional Pump Delay is Optional Displays Inlet/Outlet Temperatures and Delta Temperature Flame Failure Feature Displays Total Run HRS Molex® Harness Connection for Ease of Service

  19. Specifications DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE Heat Exchanger Head Loss & Flow Recovery Capacities MBTU Input and Output Dimensional Specifications Shipping Weights www.camus-hydronics.com www.camus-hydronics.com

  20. For Hydronic Heating – Models MFH800, 1000, 1200, 1400, 1600, 1800, 2000 For Hot Water Supply – Models MFW800, 1000, 1200, 1400, 1600, 1800, 2000 Gas Fired Residential / Light Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

  21. Performance Highlights Low NOx Up to 85% Efficiency – Non-Condensing Mode Up to 95% Efficiency – Condensing Mode Durable Ceramic Burner Unaffected by High Temperatures Vents up to 60 Feet Horizontally with 60 Feet of Air Intake Duct Suitable for Use in Negative Pressure Environments Input Range From 800 to 2000 MBTUH Complete Diagnostic Light Package Easy Access for Inspection and Cleaning of Heat Exchanger Tubes Durable Ceramic Fiber Refractory Simple to Service With Easy Access to Burner and Fan

  22. Control Panel Accurate Proportional Control with up to 4-Stage Option Incorporates Auto Reset High Limit and Operator Six Modes of Operation, for Outdoor Reset, Heating, DHW and Remote Port for Optional Tank Sensor Optional Pump Delay Flame Failure Feature Displays Inlet/Outlet Temp’s Firing Modes Available: and Delta Temperature On / Off Models 800 - 1000 Displays Total Run HRS 2-Stage Molex® Harness Connection for Ease of Service On / Off Models 1200 – 2000 Weather Proof Enclosure 2-Stage 3-Stage Fusible Link for Over-Voltage 4-Stage Proven Field Performance

  23. Specifications DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE Heat Exchanger Head Loss & Flow Recovery Capacities MBTU Input and Output Dimensional Specifications Shipping Weights www.camus-hydronics.com www.camus-hydronics.com

  24. For Hydronic Heating – Models MFNH2000, 2500, 3000, 3500, 4000 For Hot Water Supply – Models MFNW2000, 2500, 3000, 3500, 4000 Gas Fired Commercial / Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

  25. Low NOx Up to 85% Efficiency – Non-Condensing Mode Up to 95% Efficiency – Condensing Mode Durable Ceramic Burner Unaffected by High Temperatures Vents up to 60 Feet Horizontally with 60 Feet of Air Intake Duct Suitable for Use in Negative Pressure Environments Input Range From 2000 to 4000 MBTUH Complete Diagnostic Light Package Easy Access for Inspection and Cleaning of Heat Exchanger Tubes Durable Ceramic Fiber Refractory Simple to Service With Easy Access to Burner and Fan

  26. Accurate Proportional Control With Up To 4-Stage Option Incorporates Auto Reset High Limit and Operator Six Modes of Operation, for Outdoor Reset, Heating, DHW, and Remote Port for Optional Tank Sensor Optional Pump Delay Flame Failure Feature Displays Inlet/Outlet Temp’s And Delta Temperature Displays Total Run HRS Firing Modes Available: Molex® Harness Connection for Ease of Service On / Off Models 2000 - 4000 Weather Proof Enclosure 2-Stage Fusible Link for Over-Voltage Proven Field Performance 3-Stage 4-Stage

  27. Specifications DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE Heat Exchanger Head Loss & Flow Recovery Capacities MBTU Input and Output Dimensional Specifications Shipping Weights www.camus-hydronics.com www.camus-hydronics.com

  28. For Hydronic Heating – Models CFH450, 550, 650 For Hot Water Supply – Models CFW450, 550, 650 Gas Fired Commercial Copper Tube Boilers For Hydronic Heating and Hot Water Supply Gas Fired Commercial / Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

  29. Performance Highlights Low NOx Up to 85% Efficiency Minimum Standby Losses with Estimated Average AFUE Efficiencies of 82% Durable Ceramic Burner not Affected by Overheating Vents up to 60 Feet Horizontally with 60 Feet of Intake Air Duct Suitable for Use in Negative Pressure Environments Input Range From 450 to 650 MBTUH Complete Diagnostic Light Package Simple to Service With Easy Access to Burner

  30. 2-Stage Proportional Control Incorporates Auto Reset High Limit & Operator Three Modes of Operation – Heating, DHW and Remote Port for Optional Tank Sensor Flame Failure Feature Displays Inlet/Outlet Temperatures and Displays Total Run Hours Delta Temperature Snap on Molex Connection for Easy Service Weather Proof Enclosure Fusible Link for Over-Voltage

  31. Specifications DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE Heat Exchanger Head Loss & Flow Recovery Capacities MBTU Input and Output Dimensional Specifications Shipping Weights www.camus-hydronics.com www.camus-hydronics.com

  32. For Hydronic Heating – Models BFH480, 660, 840, 1020, 1200, 1380, 1560, 1740, 1950 For Hot Water Supply – Models BFW480, 660, 840, 1020, 1200, 1380, 1560, 1740, 1950 Gas Fired Commercial Copper Tube Boilers For Hydronic Heating and Hot Water Supply

  33. Diagnostic Lights Help Troubleshoot Over the Phone Optional Digital Temperature Control is Extremely Accurate to Minimize Standby Losses From Temperature Overshoot Durable Stainless Steel Burners Adaptable to Outdoor Use Simple to Service Slide Out Burner Tray Easy Side Access for Inspection of Combustion Chamber High Temperature Ceramic Fiber Tiles in Combustion Chamber Very Smooth and Quiet Operation Suitable for Venting in Low Ceiling Applications with Use of Efficiencies of up to 83% Power Venter and Low Profile Hood

  34. Incorporates Auto Reset High Limit & Operator Three Modes of Operation: Heating, DHW and Remote Port for Optional Tank Sensor Flame Failure Feature Displays Inlet/Outlet Temp’s And Delta Temperature Displays Total Run Hours * The Smartflame 780007 Control Panel Is Optional Snap on Molex® Connection For Easy Service Fusible Link for Over-Voltage Protection

  35. Venting

  36. Specifications DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE Heat Exchanger Head Loss & Flow Recovery Capacities MBTU Input and Output Dimensional Specifications Shipping Weights www.camus-hydronics.com www.camus-hydronics.com

  37. For Hydronic Heating – Models SFH420, 520, 600 For Hot Water Supply – Models SFW420, 520, 600 Gas Fired Commercial Copper Tube Boilers For Hydronic Heating and Hot Water Supply

  38. Diagnostic lights help troubleshoot over the phone Temperature control is extremely accurate to Suitable for venting in low ceiling applications Burner runs cool and requires minimum maintenance minimize standby losses from temp. overshoot With use of power venter and low profile hood Adaptable to outdoor use Simple to service Very smooth and quiet operation Fully enclosed combustion chamber Input Range From 420 to 600 MBTUH Efficiencies up to 83%

  39. Incorporates Auto Reset High Limit & Operator Three Modes of Operation – Heating, DHW and Remote Port for Optional Tank Sensor Flame Failure Feature Displays Inlet/Outlet Temperatures and Delta Temperature Displays Total Run Hours Snap on Molex Connection for Easy Service Weather Proof Enclosure Fusible Link for Over-Voltage Protection

  40. Venting

  41. Specifications DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE Heat Exchanger Head Loss & Flow Recovery Capacities MBTU Input and Output Dimensional Specifications Shipping Weights www.camus-hydronics.com www.camus-hydronics.com

  42. Standard Features Constant or Outdoor Reset temperature control Optional heating load matching software Domestic target water temperature limit to prevent boiler condensation or to maintain domestic hot water heat exchanger temperature Maximum target water temperature limit to prevent individual boiler limit tripping Warm weather shutdown of boilers and main pump(s)

  43. Standard Features (CONTINUED) Controls any type or combination of modulating & staging boilers – 12 outputs per controller – each modulating boiler uses 2 outputs, each staging boiler uses 1 output per stage; each pump uses 1 output. Some possible control configurations for a single controller application include: - controls up to 6 modulating boilers - controls up to 5 modulating boilers + 2 main pumps - controls up to 4 modulating boilers + 2 single stage boilers + 2 main pumps - controls up to 3 modulating boilers + 3 two-stage boilers

  44. Standard Features (CONTINUED) Master – Slave arrangement allows for additional controllers to be added to increase the boiler control capability. In this manner, with 2 controllers, 24 outputs are available (up to 12 mod boilers, or combination of mod and staging boilers) Runtime based lead / lag control of boilers, regardless of type Totally custom firing sequences available to allow high efficiency boilers to fire first followed by less efficient boilers Runtime based lead / lag control of main system pumps, comes with flow sensing & automatic lag pump switch-over in case lead pump should fail

  45. Optional Features Lock & key(s) to prevent unauthorized editing of parameters EMS (Energy Management System) interfaces: - enable / disable of heating controller (EMS enables or disables heating system - remote set point control of heating system (EMS provides one control override (DO) and one 0-20ma signal (AO) to Stage-Mod to take full control of Stage-Mod target temperature) Web / LAN server interface allowing each controller to communicate to any PC web-browser application Custom serial protocols available

More Related