PREOPERATIVE PLANNING OF REVISION TOTAL KNEE ARTHROPLASTY J.J. Prosser, D.O.
Introduction • Of the 200,000 TKAs performed in the U.S. in 1996, 50,000(1/4) were performed in patients under 65y/o • 20,000 revision TKAs in 1996 alone • More and more individuals at risk for implant failure
Implant Failure • 2 causes of implant failure; • 1.aseptic loosening • 2.wear related osteolysis
Implant Failure continued… • Both result in loss of periprosthetic bone • Stability of revision implant depends on quantity and quality of metaphyseal bone • ID bone defects on prerevision radiographs is a crucial part of preoperative planning
Goals • Shorten the learning curve of the implant system • Appropriate size- fracture vs. loosening • Correction of leg length discrepancies • Correct during surgery • Formulate alternative plans if procedure of choice can not be performed - special equipment on standby
Results • Proficient preoperative planning leads to a reduction in surgical time • It minimizes or eliminates the need for repeated steps
Planning: X-Rays • Radiographs of good quality • Known magnification
Radiographs of Good Quality • AP and lateral • AP • Must include sufficient amount of proximal femur for templating • Must provide a scale for magnification • Proper rotation- internal rotation of the hip until the head and neck are parallel with the cassette
Rotational Error • Degree of error in sizing is a function of the rotational distortion • Closer to an ideal AP projection less error in templating
Leg Length Discrepancy • Draw a line at the level of the ischial tuberosities • Relationship between this line and the lesser trochanter allows for assessment • Measure and record any discrepancies
Template of the Acetabulum • Position template so that the center of the prosthesis reproduces the center of rotation of the head • Typically the inferior margin of the acetabulum lies at the level of the obturator foramen
Sizing of the Acetabulum • Implant should contact as much of the acetabular bone as possible • Do not remove excessive amount of subchondral bone • Medial position should be at the tear drop • Eccentricities can be managed with bone grafting or eccentric cement mantles
Position of the Acetabular Component • 15 degrees of anteversion: • measured as the largest distance of the cup opening on the AP centered on the cup • 40 degrees of inclination: • measured as the angle between the longitudinal axis of the cup opening and the tear drop line
Template of the Femur • Must allow for cement mantle with cemented arthroplasties • Size and location of mantle are discretion of the surgeon • Press fit must fill the proximal canal • Size determined by template that best fits the upper femur
Head and Neck Size • No leg length discrepancy: • superimpose the center of the prosthetic head and femoral head to the acetabular center of the hip • Leg length discrepancy: • distance from the acetabular center to the femoral center should equal the discrepancy
Type and Size of the Femoral Component • Determined by adjusting medial side of the component to medial wall of the canal • The trochanteric line of the template is placed at the apex of the greater trochanter • Size determines the amount of offset • Larger the prosthesis the larger the offset
Neck Resection • Template will indicate the neck resection level • easily measured from the proximal aspect of the lesser trochanter • reproduced in surgery with adequate exposure • can also utilize the relationship between the tip of the greater trochanter and the prosthetic femoral head • Any measurements must be done with a ruler whose scale is magnified the same amount as the x-ray
Completed Template • Line B to C: leg length discrepancy • Point D: center of the acetabulum • Point E: center of femoral head • Line F: intended level of resection
Final Planning • Most templates include a magnified scale • Lateral x-ray templating done in a similar fashion • Size of the medullary plug can be determined by measuring the canal at the level of the stem • Templating the non-operative side in complicated revision cases is often helpful to assess the need for special equipment or bone graft
Checking the Plan • Fitting of trial components and instrumentation • In uncemented THAs criteria for the tightness of the stem • apply predetermined rotation and extraction forces • Postoperative x-rays: • compare components, cuts, and leg length to preop plan • check acetabular placement and orientation as well as fit of the femoral stem
Summary • Preoperative planning is a necessary first step • Shorten learning curve of prosthetic system • Minimize intraoperative guess work • Decrease surgical time • Allows for precision and reproduceability
Eggli S, Pisan M, Muller ME • The value of preoperative planning for total hip arthroplasty. • JBJS. 1998 May;80(3):382-390.
History • Both Charnley and Muller emphasized the importance of preop radiographs in deciding the type and size of prosthesis, in achieving the correct position and orientation of the components, in equalizing leg length and in reducing intraoperative complications
Study • 100 consecutive patients • THR secondary to idiopathic OA from 1985-1988 • 45 men and 55 women • Mean age of 66
Three basic steps • Appropriate type and size of prosthesis • 3 neck lengths Anatomic position and orientation of the acetabular component 40 degrees of inclination 15 degrees of anteversion Restoration of leg lengths
Results Stem- 98% type 92% size Acetabulum- 100% type 90% size Leg length- 0.9 preop 0.3 postop
Discussion • Used cemented femoral component in 90% of cases • More pre and post op agreement
Knight JL, Atwater RD. • Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. • J Arthroplasty. 1992;7 Suppl:403-409.
Study • 110 primary THA • Cemented and uncemented
Results • Preop estimate of magnification differed from actual magnification • Preop bone morphology did not correlate with type of femoral stem fixation • Preop estimate • Acetabular cups- 62% • Cemented stem- 78% • Cementless- 42% Leg length equalization 70%
Discussion • Surgeons need better methods to estimate bone morphology and magnification from preop radiographs • Preop planning may not reduce intraoperative complications