Improved energy efficiency with surface heating and cooling

Improved energy efficiency with surface heating and cooling. Lars Nielsen Ilari Aho Uponor Group REHVA Supporters’ Seminar Amsterdam, May 14, 2009. Presentation outline. Uponor in brief The EPBD and its relation to Uponor solutions The Exergy concept and LowEx solutions

nadda
Télécharger la présentation

Improved energy efficiency with surface heating and cooling

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Improved energy efficiency with surface heating and cooling Lars Nielsen Ilari Aho Uponor Group REHVA Supporters’ Seminar Amsterdam, May 14, 2009

  2. Presentation outline • Uponor in brief • The EPBD and its relation to Uponor solutions • The Exergy concept and LowEx solutions • Radiant heating & cooling solutions • Case Study ZUB • Summary and Conclusions

  3. Uponor key facts: Company • Leading provider of plumbing & indoor climate systems in Europe and North America • Market leader in infrastructure pipe systems in the Nordic countries • Net sales for 2008: EUR 950 million • Operations in 30 countries with 11 factories in 6 countries • Personnel: ca 3,800 persons • Listed in NASDAQ OMX Nordic in Helsinki

  4. Response measures to the EPBD recast • Low Exergy System Design • Radiant Heating & Cooling Solutions • High energy efficiency improvement potential (5-50%) • Low temp. heating & high temp. cooling optimal for heat pumps, district heating etc. • Optimal utilisation of free and renewable energy sources • Superior indoor comfort! EPBD Main Pillars: • Energy performance requirements for new buildings • Energy performance requirements for existing buildings that undergo major renovation • Energy performance certificates • Inspection of heating and air-conditioning systems Preference to: • Decentralised energy supply systems based on renewable energy • Cogeneration • District or block heating or cooling • Heat pumps

  5. The Exergy Concept • Exergy is the ability of an energy flow to do work • Exergy combines the quality and quantity of energy • Exergy analysis is established practice in power plant optimisation, industrial ecology, etc • First applications to the building sector in the 1990s • Exergy in practice: • Match the quality of supplied energy to the quality needs of the demand side • Low temperature heating and high temperature cooling (Rehva guidebook no. 7) • Optimal utilisation of low quality energy in district heating and district cooling systems

  6. Integrated water based systems ensure Exergy performance High-performance buildingsHydronic Heating & Cooling system LowEx Supply structuresDistrict Heating, District Cooling

  7. Uponor Indoor Climate SolutionsInvisible Comfort • Under floor heating and cooling systems • Thermally ActiveBuilding Systems(TABS) • Cooling panels andsurface cooling elements • Radiant heating and cooling controls • Pre-insulated piping systems • Ground energy collector systems • Ventilation ducting

  8. Radiant cooling solutions Cooling panels • Both new build and refurbishment • Office, commercial and publicbuildings • Floor cooling • Office, commercial, public and residential buildings • Mainly for new build • Capillary mats • Office, commercial, public and residential buildings • Both new build and refurbishment • Thermally Active Building Systems • Office, commercial and public buildings • For new build only

  9. Thermally Activated Building Structuresstores and releases effect when needed

  10. COP for Brine / water heat pump 6,8 kW 4,2 3,0 Low temperature heating yields optimal performance of heat pump solutions • The EPBD recast requires heat pumps to be considered for new buildings • Radiant heating and cooling systems ensures optimal heat pump performance with supply temperatures close to ambient • The Seasonal Performance Factordepends on the COP and the entire heating system • A rule of thumb for heating is that 1°C higher supply flow temperature causes up to 2.5% higher energy consumption per yea

  11. The construction of the ZUB office, research and exhibition building is an example of what today's state of the art of technology for low energy demand and sustainable building can look like. Planned as an example of a low energy building, the new office of about 1300 m² is attached to an existing preserved building and consists of three different main parts:one for exhibitions and events, one for offices, and an experimental part for different kinds of research in innovative building techniques and building services. A special focus was given to the realisation of a sustainable cooling concept, using a renewable energy source: the coolness of the ground underneath the building. Centre for Sustainable Building (ZUB), Kassel, Germany

  12. Minimised thermal losses during heating season and heat gains during cooling season Architectural design High insulation levels Solar gain control LowEx system solution 25-40 °C supply temperature for heating 16-20 °C supply temperature for cooling district heating return line utilisation and ground-coupled cooling The ZUB energy concept

  13. Summary on Low Exergy systems • LowEx concepts and integrated design provide • indoor comfort and reliability for end-users • energy and cost performance • productivity: more from less • Implementation requires • a holistic and multidisciplinary approach through project planning, design, construction and commissioning • new approaches, skills and an open mindset from HVAC design but it doesn’t require • completely new technologies • high upfront investments

  14. Conclusions • Radiant heating & cooling solutions provides • good potential for improving energy performance in response to the EPBD • optimal operating conditions for renewable energy sources • high comfort • A total system approach is required • for optimal performance of the building HVAC system • interconnected water-based systems is a key element for overall performance • Solutions for energy renovation are required • cost efficient Low Exergy renovation solutions are required for the existing building mass • radiant system can provide part of the response to increased future cooling loads