2000 Series Operational Training
420 likes | 637 Vues
2000 Series Operational Training. Foam Tank. Line Strainer. Check Valves. Flow Meter. Electronic Direct Injection Proportioner. 2000 Series. Water Tank. Multiple Discharges. Water Pump. Discharge Labels.
2000 Series Operational Training
E N D
Presentation Transcript
Foam Tank Line Strainer Check Valves Flow Meter Electronic DirectInjection Proportioner 2000 Series Water Tank Multiple Discharges Water Pump
Discharge Labels • Discharge handles and/or gauge plates are labeled “FOAM” if they can flow foam.
Digital Display Operation • Digital display reads “Hypro” upon initial power-up • System defaults to “ON” mode when engine is placed into pump • “ON” light illuminates
Digital Display Operation • Open foam discharge • Displays solution volume • “ON” light blinks when foam pump runs • To disarm system push red “FOAM” button • “ON” light turns off • System still functions as flow meter
Water flow in GPM Total gallons of water flowed Foam concentrate injection percentage Total foam concentrate injected Digital Display Information
Digital Display Operation • Water flow display • Push “SELECT” button and total volume of water discharged is displayed • Gallons, liters, imperial gallons
Digital Display Operation • Push “SELECT” button to enter “%” mode • Displays default injection percentage • “PA” Single tank system (“UP” or “DOWN” button will override default setting)
Digital Display Operation • Push “SELECT” button to enter “TOTAL FOAM” • Displays total concentrate injected
Digital Display Operation • Enter “INJECTION PERCENTAGE” from any mode • Press either “UP” or “DOWN” button momentarily to display current percentage setting • Hold either button for two seconds to change setting accordingly
Total Water % Total Foam System Reset Push both buttons while in desired mode to “0” out totals or return to default %
System Reset • Foam Manifold • Release pressure from foam manifold
Low Foam Display • “Lo.Con” display • Selected foam concentrate tank is getting low • Add concentrate within two minutes or… • “no.Con” displays • Concentrate pump shuts off • Add foam concentrate • Push “FOAM” button to restart
Exceeding Foam Injection Rate • “HI.FLO”display • Occurs when water flow exceeds the foam pump capabilities of meeting chosen concentrate injection percentage
Digital Display Operation • Simulated flow • While in “FLOW” mode, push both lower buttons simultaneously • Three bars on left indicate manual mode • Pushing red “FOAM” button will turn foam pump on/off • Pump injects to simulated flow default setting
System Air Purge • Enter “SIMULATED FLOW” • Turn injection valve from “INJECT” to “CAL/FLUSH” • Push red “FOAM” button on display to start foam pump
System Air Purge (cont.) • Run until concentrate flows steady out of dump line • Push red “FOAM” button to stop pump • Turn injection valve to “INJECT” • Exit “SIMULATED FLOW”
Power-fill System • To refill foam tank • Remove Cap • Securely attach pick-up hose to refill inlet • Place pick-up hose into foam container
Power-fill System • To refill foam tank • Turn the refill/flush valve counterclockwise to the stop for the refill position
Power-fill System • Auto fill • Push the “Green” Auto button once. • The pump will start filling the foam tank. • The Green light will flash while the pump is in operation • When the foam tank is full, the Green light is solid and the pump will stop.
Power-fill System • Manual fill • Push and hold “Red” Manual button. • The pump will start filling the foam tank. • The Red light will be solid while the pump is in operation • When the foam tank is full, the Green light will illuminate. • Release Red button
Power-fill System • Flush Operation • Turn the refill/flush valve clockwise to the stop for the flush position. • Place pick-up hose into bucket of clean water.
Power-fill System • Flush Operation • Push and hold “Red” Manual button until discharge fluid from flush drain line is clear. • Release Red button
Daily Checkout • Check foam tank level • Check foam “On-Off” valve is in ON Position. • Check that light under “FLOW” is illuminated and flow meter states “0” when master in on. • Light under ON should be illuminated. Press red button to turn unit OFF. Press again to turn unit back ON.
Weekly Checkout • Inspect wiring, hoses, flow meters and connections for tightness, corrosion, leaks and/or damage. • Check foam pump 30W non-detergent oil level with dipstick or sight level. • Clean foam strainer. • Flow foam concentrate into container checking operation of simulated flow.
Foam pump • Oil level dipstick location
Foam Concentrate Strainer • Close valve in foam concentrate supply line to service strainer
Foam Concentrate Strainer • Locate and remove strainer
Foam Concentrate Strainer • Flush out with clean water • Check gasket • Reinstall • Do not over tighten
Foam Pump Maintenance • Clean top of the foam pump to prevent oil contamination
Foam Pump Maintenance • Remove black dipstick located on top of pump
Foam Pump Maintenance • Check oil level on dipstick or • Check oil level in pump sight glass
Foam Pump Maintenance • Hypro Oil Recommended • Special agents prevent: • Scuff & wear • Moisture • Oxidation • Foaming • Rust • Use 30 wt non-detergent oil in emergency
Semi-Annual Checkout • Remove paddle wheel sensor from foam plumbing and clean with Lime-A-Way or similar cleaner.
Got Foam? (the cliff notes) • Foam • Engage pump • Foam System automatically activates. • Open any discharge labeled “FOAM” • If foam is not desired, press “Red” button on FoamPro Flow meter , system is disarmed. • Refill • Attach pick-up hose and place into container. • Activate refill pump. • Flush system • DO NOT allow refill pump to run without foam or water.