1 / 34

Electrische stroom

Electrische stroom. Stroomrichting De wet van Ohm. Weerstand van een draad Serieschakeling. Parallelschakeling. Gemengde schakeling. Energie en vermogen. Huisinstallatie. PK 2005. Het koperatoom. 27 Binnenste electronen. 2 buitenste electronen. ofwel 2 geleidingselectronen.

netis
Télécharger la présentation

Electrische stroom

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electrische stroom Stroomrichting De wet van Ohm. Weerstand van een draad Serieschakeling. Parallelschakeling. Gemengde schakeling. Energie en vermogen. Huisinstallatie PK 2005

  2. Het koperatoom 27 Binnenste electronen 2 buitenste electronen ofwel 2 geleidingselectronen ofwel 2 valentieelectronen Kern (? neutronen en 29 protonen) ofwel 2 vrije electronen Een koperdraad bevat heel veel vrije electronen:

  3. De vrije electronen zitten al overal in een metalen draad • Een spanningsbron pompt deze vrije electronen rond.

  4. 1. De stroomrichting + - + pool . . . De stroom I loopt van de . . . naar de – pool van de spanningsbron. • De vrije electronen worden • van de – pool naar de + pool gepompt. • I is voor de weerstand . . even groot . . als achter de weerstand. I e

  5. 2. De wet van Ohm U = I.R U = spanning in Volt (V) I is de stroomsterkte in Ampère (A) R is de weerstand in Ohm ()

  6. 2. De weerstand R van een draad A L R hangt af van: • De lengte L (in m) • De doorsnede A (in m2) • De soortelijke weerstand r (in Wm) Binas tabel 35

  7. Bereken de weerstand van een koperdraad van 50,0 cm lang en een doorsnede van 1,0 mm2. 2. De weerstand R van een draad. • Geg: L = 50,0 cm = 50,0.10-2 m A = 1,0 mm2 = 1,0.10-6 m2 r = 17.10-9Wm (BINAS tabel 8) • R = r.L/A = 17.10-9 . 50,0.10-2/1,0.10-6 = 8,5.10-3 W

  8. PTC: R neemt TOE als T stijgt (metalen) Bijzondere weerstanden: R is onafhankelijk van T (Nichroom o.a.) PTC TC = 0 Super-geleiding: R = 0 NTC: R neemt AF als T stijgt (halfgeleiders: C, Si) NTC

  9. 1 m P 3 m Watervallen 1 en 2 in serie 1 I1 =5 L/h I2 =5 L/h I =5 L/h 2 2 m

  10. 1 m 1 P 3 m I = 5 L/h 2 m 2 1 in serie met (2 en 3)! 2 en 3 parallel, I1 =5 L/h I2 =4 L/h I2 =5 L/h I3 =1 L/h 3

  11. + -  Bij serieschakeling geldt: 1. De stroom . . . is overal hetzelfde. Hoofdstroom Ibron = I1 = I2. 2. De bronspanning . . . wordt verdeeld. Ubron = U1 + U2 3. De vervangingsweerstand Rv . . . Rv = R1 + R2

  12. + - 1a. Bereken de hoofdstroom Voorbeeld 1: serieschakeling. 1b. Bereken U1 en U2. Ub = 12 V R1 = 40  R2 = 80 

  13. + - Rv = 120  40 + 80 = 120  Rv = R1 + R2 =  Vervang eerst beide weerstanden . . . Ub = 12 V R1 = 40  R2 = 80 

  14. Ub = 12 V + - Rv = 120  Ub = I . Rv 12 = I . 120  I = 0,10 A  De hoofdstroom berekenen . . .  Weer terug naar de beginschakeling . . . I = 0,10 A

  15. Ub = 12 V + - I = 0,10 A R1 = 40  R2 = 80  de wet van ohm toe.  Op elke weerstand passen we nu . . .  U1 = I . R1 = 0,10 . 40 = 4,0 V  U2 = I . R2 = 8,0 V 0,10 . 80 =

  16. Ub = 12 V + - R1 = 40  R2 = 80   De hoofdstroom Ib = I1 = I2 = 0,10 A  De resultaten staan in de schakeling . . .  Ub = U1 + U2 . . . 12 V = 4,0 V + 8,0 V 0,10 A 4,0 V 8,0 V

  17. Ub = 15 V + - Je wilt een 6,0 V; 0,50 A fietslampje . . . Voorbeeld 2: serieschakeling. aansluiten op een spanning van 15 V.

  18. Ub = 15 V + - Van R1 kennen we twee gegevens: Bereken de vereiste serieweerstand. U1 = 15 – 6,0 = 9,0 V I1 = 0,50 A en . . 0,50 A 9,0 V R1 6,0 V; 0,50 A

  19. V A Ub = 15 V + - R1 6,0 V; 0,50 A R1 = U1/I1 = 9,0/0,50 = 18 W We kunnen nu R1 berekenen. Nog even UL en I meten . . . 0,50 A 9,0 V = 18 W

  20. 1. De spanning over elke weerstand is. .  Bij parallelschakeling geldt: . . hetzelfde. U1 = U2. 2. De hoofdstroom wordt . . . . verdeeld. I = I1 + I2 3. De vervangingsweerstand Rv . . .

  21. Ub = 12 V + - R1 = 30  R3 = 40  R2 = 60  1. Bereken de hoofdstroom. Voorbeeld: Gemengde schakeling. 2. Bereken de stroom in elke weerstand

  22. Ub = 12 V + - R1 = 30  R1,2 = 20  R3 = 40  R2 = 60  1/R1,2 = 1/R1 + 1/R2 = 1/30 + 1/60 = 0,050 Eerst Rv van de parallelschakeling: R1,2 = 1/0,050 = 20 W

  23. Ub = 12 V + - R1 = 30  Rv = 60  R1,2 = 20  R3 = 40  R2 = 60  Rv = R1,2 + R3 = 20 + 40 = 60 W Nu Rv van de serieschakeling: Ub = I.Rv 12 = I . 60 I = 12/60 = 0,20 A 0,20 A 0,20 A Terug naar de echte schakeling . . .

  24. U3 = I3.R3 = 0,20 . 40 = 8,0 V Ub = 12 V + - I = 0,20 A I = 0,20 A R1 = 30  R3 = 40  R2 = 60  U1 = 12 – 8,0 = 4,0 V I1 = U1/R1 = 4,0/30 = 0,13 A 0,20 A I2 = U2/R2 = 4,0/60 = 0,067 A 4,0 V 8,0 V

  25. Electrische energie Ee en vermogen P: P = U.I BINAS tabel 35 • P is vermogen in W = J/s • U is spanning in V • I is stroomsterkte in A P = Ee/t of Ee = P.tBINAS tabel 35 • P in kW en t in h dan is Ee in kWh J • P in W = J/s en t in s dan is Ee in

  26. Een kachel van 500 W staat 10 h aan en 1 kWh kost € 0,11. Energierekening: • Bereken de energie en de kosten in € P = 500 W en t = 10 h • Geg.: E • Gevr.: • Opl.: Ee = P.t = 0,500 kW . 10 h = 5,0 kWh • Kosten: 5,0 . 0,11 = € 0,55

  27. Huisinstallatie M 3 x 16 A Aardleksch. kWh.mtr Hoofdz. Fase Cen-trale Nul Aardl.

  28. Overbelasting Kachel 3 x 16 A M Fase Cen-trale Nul Aardl. Aardl. Smelt door P = 4600 W U = 230 V I = P/U = 20 A

  29. Kortsluiting 3 x 16 A Aardleksch. M Hoofdz. Fase Cen-trale Nul Aardl. Aardl. Smelt door Contact tussen fase en nul

  30. Aardlekschakelaar: 3 x 16 A Aardleksch. M Hoofdz. Fase Cen-trale Nul Aardl. Aardl. Smelt niet door Aardlek reageert Contact tussen fase en aarde

  31. Aardleiding: Aardleksch. M Fase Cen-trale Nul Aardl. Aardl. Zekering smelt Kan ook reageren Contact tussen fase en kast

  32. Gevaarlijk Aardlekschakelaar Veilig

  33. Gevaarlijk:Bewusteloosheid; gevolgen voor het hart levensgevaarlijk Verdraagbaar:Verdraagbare stroom; boven 50 mA bewusteloos. Veilig:Geen invloed op hartslag en zenuwstelsel.

  34. Einde

More Related