1 / 22

Power System Conference, Clemson, South Carolina, March 8-11, 2005

Principles and Issues Relating to the Interconnection of Wind Power. Power System Conference, Clemson, South Carolina, March 8-11, 2005. Zhenyu Fan & Johan Enslin KEMA T&D CONSULTING 3801 Lake Boone Trail, Suit 200 Raleigh, NC 27607. Overview:. Study Background Key Issues

Télécharger la présentation

Power System Conference, Clemson, South Carolina, March 8-11, 2005

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Principles and Issues Relating to the Interconnection of Wind Power Power System Conference, Clemson, South Carolina, March 8-11, 2005 Zhenyu Fan & Johan Enslin KEMA T&D CONSULTING 3801 Lake Boone Trail, Suit 200 Raleigh, NC 27607

  2. Overview: • Study Background • Key Issues • Objectives & Scope • Case Studies • Summary

  3. Wind Power is growing! • Germany: 12,001 MW • Spain: 4830 MW • US: 4275 MW • Denmark: 2880 MW • India: 1702 MW Source: AWEA’s Global Market Report

  4. Region Peak Load MW Installed WindMW Penetration Denmark 5,000 3,100 62% Germany 77,000 14,600 19% Spain 36,000 6,200 17 % The Netherlands 14,000 1,000 7% Continental USA 808,000 6,740 0.8% Texas 63,000 1,288 2% New Mexico 1,500 265 17% Table 1: Example of wind systems and installed penetration levels

  5. Wind Resource in the USA

  6. Wind Power installed in US

  7. Wind Power Interconnection Studies • Interconnection procedures are not uniform • In general, interconnection procedures require: • to apply for a queue position; • system feasibility, system impact, and facilities studies; • interconnection and construction agreements; • construction of interconnection facilities, and network upgrades if required. • FERC governs the generation interconnection process

  8. Interconnected Issues: • Power Flow • Short Circuit • Transient Stability • Electromagnetic Transient

  9. Interconnected Issues (Cont.): • Protection • Power Leveling and Energy Balancing • Power Quality

  10. Network Interface Options • A – Direct link, no compensation • B – SVC, reactive power, voltage • C – STATCOM, added power quality • D – STATCOM with battery, added power balance, trading, UPS, • Black-start, etc.

  11. Case Studies: • California ISO System • Dutch Project

  12. California ISO System: • CA Wind Resources • Areas designated "Good" are roughly equivalent to an estimated mean annual power at 10 meter height of 200 Watts/square meter to 300 W/m2 and "Excellent" to above 300 W/M2. • In the year 2000, wind energy in California produced 3,604 million kilowatt-hours of electricity, about 1.27 percent of the state's total electricity. That's more than enough to light a city the size of San Francisco.

  13. California ISO System: • CA Electricity Market • The CA ISO 2004 Summer peak load is 44,422 MW with a minimum projected planning reserve of 16.4% and a corresponding operating reserve of 2,750 MW. Approximately 32,700 MW are thermal units, 2,600 MW are wind with the remaining 18,700 MW consisting of a mix of hydro, pumped storage and solar. • The 2004 base scenario forecast wind capacity for California during summer peaks is only 235 MW (9.0% of the installed wind capacity).

  14. Wind Power Operating Reserve and Regulation Impact • Load forecasting error affects operating reserves while short-term fluctuations in load affect regulation • Forecasting errors should be considered in combination • Geographical dispersion of wind resources tend to reduce the amount of incremental load following requirements

  15. Wind Power Impact on Reliability and System Operation • Hydro-power resources can be used for power balancing wind power plants, • Thermal units on the system would still be used for operating reserves. • System reliability and load following capability will not be affected significantly by the addition of a significant amount of wind generation.

  16. Wind Power Impact on Generation • The decision to build a wind plant depends on many factors. • Capacity factor of CA ISO is 9% on an annual basis, new wind project are likely to have capacity factors in the 35-40% range. • The addition of large amounts of wind generation to a system would have some economic and physical impact on merchant plants in the medium to long run.

  17. Netherlands Project Major Dutch HV Network Upgrades for interconnection of a 6,000 MW offshore wind park in the North Sea

  18. Offshore Wind Energy In Netherlands • 12% of energy within EU should be provided by renewables by the year 2010, with a possible installed wind capacity of at least 40 GW • 6000 MW by 2020 wind power studies • An energy storage system integrated with high power electronics can mitigate interconnection problems

  19. Storage Options for 6 GW Wind Farm VSC Interface • Based on Flow-battery technology • 6,000 M€, 30 years NPV, 1x1 km size • Not feasible by factor 10 as a single solution

  20. Energy Storage • A 2500 MW battery plant will be required • Total capacity is 62 GWh • Based on the difference between low and high APX-values, the profits of the reduction of the number of start/stops, and avoiding the investment cost of the stabilization system, and avoiding of the unbalance cost, the project becomes feasible. • In this case, a seven- to eight-year break-even can be achieved,

  21. Summary • Large-scale wind park requires a different integration approach from those used for smaller wind farms. • Mitigation devices are needed for the interconnection issues with distributed power • Key technologies can minimize the impact on the network • Several functions should be integrated into the functionality of the energy storage system

  22. Thank You !

More Related