1 / 12

If agglutination is observed, STOP the test and perform cell washing procedures before proceeding.

RapidVet ® -H Blood Group Determination System for Identifying DEA 1.1 Positive and DEA 1.1 Negative Dogs.

nizana
Télécharger la présentation

If agglutination is observed, STOP the test and perform cell washing procedures before proceeding.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RapidVet®-HBlood Group Determination Systemfor Identifying DEA 1.1 Positive and DEA 1.1 Negative Dogs

  2. Kit contains:auto-agglutination saline screen cards, patient test cards, pipettes, stirrers, diluent, instructions, interpretation guideand report card.Shelf-life: 24 months at room temperature

  3. Prior to typing, check for auto-agglutination using the card provided in the kit. This card is used for three patients and, after use, should be returned to the kit box. If agglutination is observed, STOP the test and perform cell washing procedures before proceeding. If auto-agglutination does not occur, proceed to the next step.

  4. Remove the Test Card from its plastic sleeve. Write the name/number of the dog and the testing date on the card.

  5. Dispense 1 drop of diluent from the dropping bottle into each well.

  6. Aspirate a small amount of patient sample into a pipette and release 1 drop (50µl) into each well, taking care not to cross-contaminate the wells.

  7. Using a NEW stirrer and pressing downward with the flat portion of the stirrer, spread and mix the materials within the entirety of the first well for about 10 seconds.

  8. Using a NEW stirrer, spread and mix the materials within the entirety of the second well for about 10 seconds.

  9. Using a NEW stirrer, spread and mix the materials within the entirety of the third well for about 10 seconds.

  10. Rock the card, using a transaxial motion, for 1 minute. Be sure materials are mixing and “rotating” within each individual well. Be careful not to cross-contaminate.

  11. Read the results, noting whether agglutination has or has not occurred in the “Patient Test” well. DEA 1.1 DEA 1.1+

  12. After the card has been read, take a digital photograph for a permanent record, or allow to dry and replace in its plastic sleeve as a permanent record.