220 likes | 391 Vues
HUB Solutions for Multi-Site Collaboration Christopher Kim June 4, 2008. 1. Project Plan. Project Goal: One Teamcenter Connectivity Project Duration: 9 Months Project Baseline: TCE V9.1.7a Project Team: Three (3) Siemens PLM Software Consultants Seven (7) Hamilton Sundstrand IT Staff.
E N D
HUB Solutions for Multi-Site CollaborationChristopher KimJune 4, 2008 1
Project Plan • Project Goal: One Teamcenter Connectivity • Project Duration: 9 Months • Project Baseline: TCE V9.1.7a • Project Team: • Three (3) Siemens PLM Software Consultants • Seven (7) Hamilton Sundstrand IT Staff
Project Scope • Implement Hub Architecture • Data Security • Data Integrity • Domestic Site Collaboration • External Site Collaboration • Auditing Capability • Data Migration 3
Project Schedule • Major Milestones • Project Planning • Project Requirement Gathering • Analysis & Design • Implementation • Validation • Data Migration • Go-Live
Multi-Site Network Essential • Object Directory Services (ODS) : Object Locator • Integrated Distributed Services Manager (IDSM) : Object Transporter • Export an object from the owning site • Transmit it over the network • Import it into the destination site
Before HUB Implementation Multi-Site Connectivity IDSM Connectivity Synchronization between all connected sites US 2 FN 1 US 1 FN 3 FN 2 T2 ODS Connectivity Auto-publication & registration only affects Domestic sites ODS 1 FN 2 ODS 2 ODS 3 US 3
After Hub Implementation Hub Connectivity FN 3 IDSM Connectivity Synchronization between all connected sites US 1 FN 1 HUB US 3 ODS Connectivity Auto-publication only affects Domestic sites HUBODS FNODS US 2 FN 2 FN 2 T2
New Partner Site Addition Hub Connectivity FN 3 IDSM Connectivity Synchronization between all connected sites US 1 FN 1 HUB US 3 ODS Connectivity Auto-publication only affects Domestic sites HUBODS FNODS US 2 FN 2 FN 2 T2 New Partner Site
Data Security - Project • Project Based Security • External Access Project • External Work Project • Common Parts Project
Projects in HUB HUB FN Projects FN 1 US 1 Partner Projects Partner
Data Security – Propagation Rule • Exportable Data Options • Entire BOM / Top Level Item Only • Transfer / Export - Protected Components • All Versions / All Files
Data Security – Rule Tree • Common Rule Tree • Domestic Sites • HUB
Data Security - Workflow • Workflows for Data Transfer • Grant Access to Foreign / Partner Site • Grant Ownership to Foreign / Partner Site • Data Replication to Domestic Site • Data Ownership Transfer to Domestic Site
Import Remote… • Dynamic Import (Pull) • Replication between Domestic Sites • Domestic Site Domestic Site • External Site Transaction (Replica & Ownership Change) • Hub External Site
Data Integrity • Item ID Registration • Eliminate Duplicated Item • Publication for Domestic Sites • Data Search for Published Data • Data Synchronization • Hourly Synch. (Sites to HUB) • Daily Synch. (HUB to Sites) • Dynamic Synch. (Need Based)
Auditing Data • Audit Reports • Currently Accessible to Foreign Sites • Currently Accessed by Foreign Sites • Exported Data to Other Sites • Workflows • Data Ownership Transfer History
Implementation - Configuration • Configuration • Preferences (iman_env) • Project (Read Only / Read-Write) • Role (Export / Outsource Control) • Rule Tree
Workflow for Data Export • Workflow for Data Transaction • Domestic Site Ownership Change • Domestic Site Domestic Site • External Site Transaction (Replica & Ownership Change) • Domestic Site HUB • HUB External Site • EPM-send-target-objects (Action Handler) • IDSM exports from Current Site • IDSM imports to Target Site
Applied Rule Tree Example • Data when Designer initiates Workflow • Outsource Controller assigns Data to Project
Implementation - Data Migration • Export Records among Sites • Import Export Record (IXR) • Remove Old IXR between Sites • Build New IXR with HUB
References • Teamcenter Engineering Multi-Site Collaboration Help • Teamcenter Engineering Utilities Reference • Teamcenter Engineering Workflow Designer Help
Q & A 22