1 / 32

Prof. Mel Ulmer DEPT OF PHYSICS & ASTRONOMY

Prof. Mel Ulmer DEPT OF PHYSICS & ASTRONOMY. The Concept:. Intact Electroforming Multilayer Process. Coated Mandrel. Astrophysical Motivation. Hard X-ray Astronomy (20- 100 keV) is rich but:. Need focusing for improved sensitivity and imaging.

pia
Télécharger la présentation

Prof. Mel Ulmer DEPT OF PHYSICS & ASTRONOMY

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Prof. Mel Ulmer DEPT OF PHYSICS & ASTRONOMY

  2. The Concept: Intact Electroforming Multilayer Process

  3. Coated Mandrel

  4. Astrophysical Motivation • Hard X-ray Astronomy (20- 100 keV) is rich but: • Need focusing for improved sensitivity and imaging • Flexible design of focal length • Need the best angular resolution possible

  5. resolution 1.5 2.25 3. arc min 45 arc sec resolution 15 22.5 arc sec

  6. Gal. Cen. Cas A 8.5 x 8.5 arc min 1.3 x 1.3 arc min 3C 273 Per A 24 x 24 arc sec 3.5 x 3.5 arc min

  7. Advantages of IEMP: • Coat Mandrel => Focal Length, small as 1-2 meters => SMEX is possible • Electroforming offers the best angular resolution (< 10 arc sec) outside custom figuring • An additional advantage of proccess at NU = • CNx coating (10 nm) smooths & protects

  8. Now the entire process: Coat mandrel with CNx Coat mandrel with release layer Coat with multilayers Coat with adhesion layers Electroform Remove electroform Remove release layer

  9. Therefore, Total Institutional Integration is VERY IMPORTANT

  10. Two different orientations about optical axis, same energy About 90 deg rotation

  11. Higher Energy

  12. Conclusion: Excellent Multilayers because: • Same Bragg angles at different energies, more penetrating versus less • Narrow Bragg peaks • One multilayer d-spacing = 5.29 nm fits all • Same Bragg angles at different axis rotations • All the above plus fits indicate well over 10% efficiency. How high? Perhaps near theoretical = 80%

  13. 30 cm long, 12 cm dia. 2 m focal length Wolter I With multilayers First Light

  14. Where do we go from here? • Further analysis of in hand mirror to cement reflectivity efficiency estimates • Advance to an even better truncated cone mandrel • Move to graded d-spacing with new multilayer coating chamber • Advance to Wolter I mirrors and fly them!!

  15. Co-Authors: Bob I. Altkorn, Anita Madan, Mike Graham, and Yong S. Chu Helpers, collaborators, etc. : Al Krieger, Dan Parsignault, Derrick Mancini, Matt Steele, Peter Takcas, Yip-Wah Chung, Jane Chang NASA Support: SR&T and Con X www.astro.nwu.edu/astro/faculty/ulmer

  16. We are ready to go! Just send money!!

  17. The End

More Related