html5-img
1 / 24

PSC 4011

PSC 4011. Electricity: What’s the connection?. PSC 4011: AC-DC, Transmission & Distribution. Direct Current (DC): _I never changes direction _Voltage is constant* _Intensity is constant* * V & I are constant if R is kept constant. PSC 4011: AC-DC, Transmission & Distribution.

ping
Télécharger la présentation

PSC 4011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PSC 4011 Electricity: What’s the connection?

  2. PSC 4011: AC-DC, Transmission & Distribution Direct Current (DC): _I never changes direction _Voltage is constant* _Intensity is constant* * V & I are constant if R is kept constant

  3. PSC 4011: AC-DC, Transmission & Distribution Direct Current (DC): _Used to operate portable battery-operated devices (mp3 players, toys, remote controls, etc.)

  4. PSC 4011: AC-DC, Transmission & Distribution Alternating Current (AC): _ I (and V) regularly change direction _ I (and V) are not constant _Vrms = 0.707 Vpeak _ Irms= 0.707 Ipeak _ Change of direction is given by frequency value *rms: root mean square value (average value)

  5. PSC 4011: AC-DC, Transmission & Distribution Alternating Current (AC): _Can be converted to DC using a rectifer _Use a transformer to increase or decrease voltage *DC can be converted into AC using an inverter (less common)

  6. PSC 4011: AC-DC, Transmission & Distribution Practice An electric range operates on 240 Vrms. _Between which two voltage values does it oscillate? _Calculate Irms and Ipeak when it draws 5000W of power. Vrms= 0.707 Vpeak Vpeak= Vrms / 0.707 = 240V / 0.707 Vpeak= 339 V (-339V & 339V) P = Vrms*Irms Irms= P/ Vrms = 5000 W / 240 V Irms = 21 A Irms= 0.707 Ipeak Ipeak= Irms/ 0.707 = 21A / 0.707 Ipeak= 30 A (-30A & 30A)

  7. PSC 4011: AC-DC, Transmission & Distribution • Power systems generate AC (at 60 Hz) • AC is transmitted through high tension wires • AC is rectified (or not) into DC for residential use • AC’s voltage is changed by transformers for residential use

  8. PSC 4011: AC-DC, Transmission & Distribution Step down transformers • Voltage secondary winding is lower than at primary winding • Number of turns of secondary winding is less than the number of turns of primary winding • Current intensity of secondary winding is higher than at primary winding Pprimary (Pp) = Psecondary (Ps) VpIp = Vs Is If Vs < Vp then Is > Ip for Pp= Ps • Joule Effect more pronounced for secondary winding (P = RI2)

  9. PSC 4011: AC-DC, Transmission & Distribution Step up transformers • Voltage secondary winding is higher than at primary winding • Number of turns of secondary winding is more than the number of turns of primary winding • Current intensity of secondary winding is lower than at primary winding Pprimary (Pp) = Psecondary (Ps) VpIp = Vs Is If Vs > Vp then Is < Ip for Pp= Ps • Joule Effect more pronounced for primary winding (P = RI2)

  10. PSC 4011: AC-DC, Transmission & Distribution From transformer to residential use: • All wires from transformer go to the distribution panel (house’s electrical box) • Distribution panel contains the main and the bus bars • Each bus bar is connected to one of the wires from the transformer • From distribution panel to house: branch circuits (circuit loops of two-way current)

  11. PSC 4011: AC-DC, Transmission & Distribution Connection between transformer wires and bus bars (distribution panel):

  12. PSC 4011: AC-DC, Transmission & Distribution Branch circuits (120 V) • Between a live bus bar (120 V: black or red wire) and the neutral bus bar (0 V: white wire) • Require one circuit breaker (after live bus bar) Branch circuits (240 V) • Between two live bus bars (120 V: black and red wires) and the neutral bus bar (0 V: white wire) • Require two circuit breakers (after both live bus bars)

  13. PSC 4011: AC-DC, Transmission & Distribution Conductors • Quebec uses American Wire Gage (AWG) notation • AWG notation’s high number, small diameter conductor • AWG notation’s lownumber, bigdiameter conductor • AWG notation’s high number, high resistance conductor • AWG notation’s lownumber, lowresistance conductor

  14. PSC 4011: AC-DC, Transmission & Distribution Practice Consider three conductor wires measuring 12, 14 and 16 AWG. _Which one is the largest? _Which one has the highest resistance? _Which one can carry the most current without overheating? 12 16 12

  15. PSC 4011: AC-DC, Transmission & Distribution General purpose branch circuits (for 120 V- outlets or rarely used appliances) Branch circuits that power several parallel outlets. Thus, the same power is provided to several independent outlets and light fixtures (e.g. for two bedrooms)

  16. PSC 4011: AC-DC, Transmission & Distribution Single purpose branch circuits (for 240 V- outlets or appliances that demand much more energy) Branch circuits that power one outlet. Thus, the highest possible power is provided to the outlet and appliance connected to it (e.g. electric range or clothes dryer)

  17. PSC 4011: AC-DC, Transmission & Distribution Single purpose branch circuits _Very useful in kitchen or workshops _Must avoid multiple plug connections (e.g. “octopus” configuration) in order to: • Not exceed I supplied by wires or limited by fuse or circuit breakers • Not risk overheating of wires or maybe even a fire

  18. PSC 4011: AC-DC, Transmission & Distribution Outlets Make possible to plug appliances into the distribution circuit Most popular: double outlet (accommodates two plugs)

  19. PSC 4011: AC-DC, Transmission & Distribution

  20. PSC 4011: AC-DC, Transmission & Distribution

  21. PSC 4011: AC-DC, Transmission & Distribution

  22. PSC 4011: AC-DC, Transmission & Distribution Practice

  23. PSC 4011: AC-DC, Transmission & Distribution

  24. PSC 4011: AC-DC, Transmission & Distribution Three-prong plugs • Mostly for metal housing appliances • Third prong is a safety precaution • Third prong maintains housing at 0V (brings current to ground) • Keeps you from electroshock

More Related