1 / 13

Top Quality Check Valves Manuafactured By Maniks

Stop check valves are mainly known for two main purposes: 1) as a globe type valve, they isolate or regulate flow the flow of liquid and 2) stop check valve can be modified as a check valve, to prevent reverse flow. In other words, these valves are generally used as a globe type valve to stop or start the flow of the liquid, as well as they also act as a check type valve to automatically close when pressure is lost, thus preventing backflow of media that may cause damage to the equipments like boilers or pumps.

pooja1234
Télécharger la présentation

Top Quality Check Valves Manuafactured By Maniks

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Stop Check Valve Stop CheckValves-Maniks http://www.maniks.com/stop-check-valves.html

  2. Agenda • About us • What is Stop Check Valve? • Stop Check Valve Function • Stop Check Valve Design • Maniks Stop Check Valve Installation • Stop Check Valve Technical Specifications • Application of Stop Check Valves • Why Maniks Stop Check Valves? http://www.maniks.com/stop-check-valves.html

  3. Maniks Stop Check Valves • About us: • Maniks is the most reputed Indian brand with a history of 30 years for manufacturing , leaded by a group of technocrats, emerged with a vital directive of presenting state of the art goods and services in the field of Energy Savings. • With the huge experience of Maniks in the Refrigeration and Air-conditioning Industry, MANIKS has selected "Waste Heat Recovery through AC & R Compressors“, “Stop Valves”, “Stop Check Valves”, “Regulating Valve” as the measure to achieve large energy savings in the industries like Dairy & Food Beverages, Hotel & Hospitality, Pharmacy & Chemical, Textile and Specialty Hospitals etc. http://www.maniks.com/stop-check-valves.html

  4. Maniks Stop Check Valve • Maniks Stop Check Valves : • Maniks Stop check valves are like having two valves in one 1) as a globe type valve, they isolate or regulate flow the flow of liquid and 2) stop check valve can be modified as a check valve, to prevent reverse flow. They provide a comparatively efficient and economic solution where regulation, isolation and prevention of backflow of fluid are required as performance characteristics for a piping system. http://www.maniks.com/stop-check-valves.html

  5. Maniks Stop Check Valves • What is Maniks Stop Check Valves? • A stop-check valve, also called as a non-return stop check valveor check valve to stop flow of liquid regardless of flow direction or pressure. Stop check valves play a crucial role in several industries in order to protect boilers and many other types of equipment. • Stop check valves are mainly known for two main purposes: 1) as a globe type valve, they isolate or regulate flow the flow of liquid and 2) stop check valve can be modified as a check valve, to prevent reverse flow. In other words, these valves are generally used as a globe type valve to stop or start the flow of the liquid, as well as they also act as a check type valve to automatically close when pressure is lost, thus preventing backflow of media that may cause damage to the equipments like boilers or pumps. • Because of this reason, having an appropriate stop check valve is like having two types of valves in one. http://www.maniks.com/stop-check-valves.html

  6. Maniks Stop Check Valve • Stop Check Valve Function : • Stop check valves are self-automated valves and they do not require any external control or human intervention, instead it relies completely on the flow of liquid to open and close. • These valves typically have two openings, one for media to enter in the valve and other for the liquid to leave. In simple words, stop check valves allow a media to flow only in one direction and prevents fluid to flow in opposite direction. These valves are basically used everywhere, including household uses and in every industry. Like other types of valves, Check type valves can be used with different types of fluids like air, gases, liquid etc. http://www.maniks.com/stop-check-valves.html

  7. ManiksStop Check Valve Stop Check Valve Design • Connections: • Butt-weld DIN (EN 10220)- ME 15 - 125 (½ - 5 in.) • Butt-weld ANSI (B 36.10 Schedule 80), - ME 15 - 40 (½ - 1½ in.) • Butt-weld ANSI (B 36.10 Schedule 40), - ME 50 - 125 (2 - 5 in.) • Socket-weld ANSI (B 16.11), - ME 50 (2 in.) • Packing gland (MSCA-X) : • The "full temperature range" packing gland is the standard for the entire MSVL platform. • This ensures perfect tightness throughout the whole temperature range: –60/+150°C (–76/+302°F). http://www.maniks.com/stop-check-valves.html

  8. Damping chamber: • The chamber is filled with refrigerants (gas or liquid), which provides a damping effect when the valve opens and closes. • Housing: • The housing is made from special, imported, cold resistant steel. • Valve Cone: • Valve cone is designed with built in metallic stop that prevents harm to Teflon ring in case of over tightening. • Spindle (MSCA-X): • Made of polished stainless steel, which is ideal for O-ring sealing. http://www.maniks.com/stop-check-valves.html

  9. Maniks Stop Check Valve Installation • The check valve must be mounted vertically with the cone downwards. The valve is designed to resist very high internal pressure. However, the piping system in general should be designed to avoid liquid traps and reduce the risk of hydraulic pressure caused by thermal expansion. • For further information about check valves refer to installation instructions for MSCHV-X/ MSCA-X. If cold refrigeration oil having low viscosity enters and settles in the damping chamber, problems with the check valve may arise. Consequently, it may be necessary to modify the valve for more viscous liquids by enlarging the hole to the damping chamber. http://www.maniks.com/stop-check-valves.html

  10. Technical Specifications • Refrigerants: Applicable to HCFC, HFC, R744 (CO2) and R717 (Ammonia). For further details refer to product instruction for MSCHV-X/ MSCA-X. • It looks same as a globe valve on the outside, however, it is essentially a lift check valve provides with a manual control to regulate continuous opening and closing, and to be completely stopped. These valves are basically applied in power plants, in applications like steam generator, stater water, boiler circulation, turbine cooling, boiler feedwater, and safety systems. http://www.maniks.com/stop-check-valves.html

  11. Maniks Stop Check Valves Stop Valve Applications: • Water, Oil Pumps • Industrial Processes • Domestic Use • Boiler Application • Pipeline Processes http://www.maniks.com/stop-check-valves.html

  12. Maniks Stop Check Valves • Why Maniks Stop Check Valves? • We give very prompt after-sales service and our technicians have vast knowledge of not only our own products, but also the entire system. This helps in quick fault-finding at customer's site. Through years of association with us, our customers know that scientific import substitution and technical knowledge is our forte. This has prompted many of our customers to send us imported samples along with their requirements for import substitution. This has led to our market oriented growth with optimal efforts. This growth has led us to export markets as well. We have been exporting our products to Gulf countries, Bangladesh and Kenya. Our products have been standardized by them for many years. • For more Information: enquiry@maniks.com http://www.maniks.com/stop-check-valves.html

  13. Maniks Stop Check Valves Thank You http://www.maniks.com/stop-check-valves.html

More Related