PROJECT SANET II

PROJECT SANET II. Pavol Horváth, Marian Ďurkovič, Tibor Weis SANET Slovak Academic Network Association horvath @sanet.sk, md@bts.sk , tibor @pobox.sk. I. . PROJE C KT SANET II. Goals of the project Adopted by Slovak Government in May 2001 Finance plan for 2001 - 2002: 5.5 mil.EUR

quilla
Télécharger la présentation

PROJECT SANET II

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PROJECT SANET II Pavol Horváth, Marian Ďurkovič, Tibor Weis SANET Slovak Academic Network Association horvath@sanet.sk, md@bts.sk, tibor@pobox.sk I 

  2. PROJECKT SANET II • Goals of the project • Adopted by Slovak Government in May 2001 • Finance plan for 2001 - 2002: 5.5 mil.EUR • Build up a new country wide optical infrastructure • Connecting all Slovak universities other academic sites • Build up MANs in the 8 main regional centres • International connection to GEANT Network • Upgrade connectivity to INTERNET

  3. Organisation of the project • All decisions are made by Project Steering Committee reported direct to minister of education of the SR • We have received a world price for leased FO for the regional infrastructure • The Tender was open for alll suppliers for • Leased Dark fibber lines ( one pair for the long distance) • To sell a free duck • To build up the FO lines for SANET mainly in the MAN

  4. Basic Technology • Fibre optic infrastructure only • Technology switched Ethernet

  5. Current situation • First 550 km optical infrastructure - 1Gbpsnetwork Bratislava - Košice ( a main part of Slovak backbone is working ) • The next 400 km is finalized ( in the next 2-3 months) • 12 km MAN in Bratislave in the SANET ownership with the 1Gbps MAN • The same situation in the Cities Nitra, Kosice • In the next 2 month will be finalized 1Gbps MAN network in the other 5 main Cities in the Slovakia

  6. Project follow up in the 2003 • Finalization all steps of the country wide optical infrastructure • The 10 Gbps switched Ethernet on the MAN in Bratislava and also in the part of backbone infrastructure was tested • Upgrade of international capacity to 355 Mbps • The new Multimedia application and services • IP telephony • IP video - real video from SATELITE ASTRA • SW free (www.videolan.org) • Teleconferences

  7. SANETII network throughput measurement • SANET2 network throughput measurement was done from 16 to 31 July 2002 during full production operation • we did not use any special part of SANET2 network for testing • The distance between Zvolen and Bratislava is 265km.

  8. The main goal of our measurement was: • To verify real capacity of SANET II network • To find out error rate during high volume data transfer • To check out limit of used network components

  9. How was measured • 2 Servers Sun Fire V880 with gigabit Ethernet network cards was used • These servers were together connected by three ways • The reason was to get comparative results> • Local interconnection through L2 switch – both • Servers were on the same IP network • Local interconnection through L3 switch – the servers was on two different IP network • Remote interconnection through L3 switches – the servers were in two cities connected to different IP network

  10. The main goal of this measurement was: • To verify real capacity of SANET II network between TU Zvolen and STU Bratislava • To check out the influence of 3ms delay caused by 265km distance on data transfer • To check out error rate during high volume data transfer •  All tests and measurements were performed during working days when average network load measured by Cisco IOS’s was 8%

  11. Summary Following results: • Using bigger TCP window, as is default set up in Solaris9, the delay caused by distance is negligible. • During high volume data transfer with average network load above 80% the error rate is still zero. • Network technology – switched gigabit Ethernet is suitable also for long distance • Network architecture where all backbone routers are connected to one VLAN allows us to transfer data on L2 level. • SANET II network is able to provide with real end-to-end network capacity up to 895Mbps in real operation to its users.