1 / 18

Motivation for high-pt PID in PHENIX high-pt detector MRPC TOF in PHENIX Prototype runs

Time of Flight System for the PHENIX high-p T Detector Upgrade Julia Velkovska (Vanderbilt) , for PHENIX. Motivation for high-pt PID in PHENIX high-pt detector MRPC TOF in PHENIX Prototype runs Final design. Physics motivation for the high-p T detector. Phys. Rev. Lett 91, 172301 (2003).

ranger
Télécharger la présentation

Motivation for high-pt PID in PHENIX high-pt detector MRPC TOF in PHENIX Prototype runs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Time of Flight System for the PHENIX high-pT Detector UpgradeJulia Velkovska (Vanderbilt) , for PHENIX • Motivation for high-pt PID in PHENIX • high-pt detector • MRPC TOF in PHENIX • Prototype runs • Final design J.Velkovska PANIC05

  2. Physics motivation for the high-pT detector Phys. Rev. Lett 91, 172301(2003). • Large suppression of p0 • Non-suppression of protons and anti-protons • Large baryon/meson ratios, a factor of 3 above standard fragmentation “ The large (anti)baryon to pion excess relative to expectations from parton fragmentation functions remains the most striking unpredicted experimental observation at RHIC. The data clearly indicates that a new mechanism other than universal parton fragmentation is the dominant source of baryons and anti-baryons in the intermediate pT range in heavy ion collisions. “ Phenix White paper • PID out to ~ 10 GeV needed ! J.Velkovska PANIC05

  3. PID scheme with TOF, RICH and Aerogel • System requirements for TOF: • Resolution s < 100 ps • Efficiency > 95 % • Occupancy < 10 % • Total cost < 500k : MRPC TOF wins over scintillator TOF J.Velkovska PANIC05

  4. The high-pT detector in PHEINIX • ACC installed in Run4 , Run5 • MRPC prototype tested in Run5 • Large area MRPC will be installed for Run6 J.Velkovska PANIC05

  5. What is a MRPC ? J.Velkovska PANIC05

  6. Honeycomb width = 12 cm Total active area width = 11.2 cm Strip width = 2.81 cm Readout strip thickness = 0.5 mm Strip interval = 0.3 cm PCB thickness = 1.5 mm Outer glass = 1.1 mm Inner glass = 0.55 mm carbon tape = 0.9 mm Mylar thickness = 0.25 mm Honeycomb thickness = 9.5 mm Inner glass width = 11.2 cm Outer glass width = 11.5 cm Glass Electrode Mylar PC board Readout pad Honeycomb Standoff PCB width = 13 cm PCB length = 42.8 cm Outer glass length = 37.4 cm Strip length = 37 cm Honeycomb = 38 cm Inner glass length = 37 cm PHENIX MRPC final design Gas gap = 0.23 mm J.Velkovska PANIC05

  7. Here is how an early prototype looked: …now the honeycomb is thinner, the spacers are the exact size, the strips have slightly different dimensions, but the internal structure is the same J.Velkovska PANIC05

  8. 3 Prototypes tested at KEK in June 2004 PH1 PH2 PH3 • Different pad/strip design, same structure inside • PH1: 50.9 x 53.5 cm2, 32 strips, readout at both ends. • PH2: 12.5 x 53.5 cm2, 8 strips, readout at both ends. • PH3: 12.7 x 53.7 cm2, 48 pads (6x2 cm2), similar to STAR MRPC. J.Velkovska PANIC05

  9. KEK T1 beam line J.Velkovska PANIC05

  10. + p PH2 Streamer Avalanche efficiency T = 68 ps (best value) J.Velkovska PANIC05

  11. KEK beam test results Efficiency Time Resolution Gas mixture:95%/5% r134a, iC4H10 • PH1: worse timing resolution (>150 ps), same efficency as PH2. Problem on uniformity • of performance across the chamber. Difficulties in mechanical assembly. • PH2: 68ps timing resolution at optimal condition, • but 90% efficiency. Solution  increase strip width. • PH3: comparable timing resolution with PH2 (best value: 67ps), 98% efficiency. J.Velkovska PANIC05

  12. To test TOF.W prototype in the PHENIX environment Test 3 prototypes for 3 months continuous operation in AA beam conditions Operate the detector within PHENIX Check timing resolution and efficiency To test electronics chain ( pre-amp +FEMs) Can we use analog signal (only) from RICE pre-amp + TOF.E design FEMs and retain the timing resolution obtained in test beam at KEK RUN5 goals J.Velkovska PANIC05

  13. RUN5 configuration: 2 boxes as shown PH4 PH4 PH3 PH2 • PH2 and PH3 previously tested. PH4 – wider strips – considered for final design J.Velkovska PANIC05

  14. RUN 5: MRPCs before installation • 192 electronics channels instrumented • To test digitization on-board vs digitization in the FEMs : both analog and digital signals were read-out from selected strips • Digitization in FEMs desirable because: • Proven technology (used since day1 in TOF-East) • Less dissipated power at the detector – can operate with air cooling J.Velkovska PANIC05

  15. RUN 5 results : timing resolution • Comparable performance in both read-out chains • Resolution for full start ( BBC) + stop (MRPC) ~ 100 ps • Design goal for both detector and electronics is met ! J.Velkovska PANIC05

  16. Final design: • 1024 readout channels • 128 MRPCs , 4 strips/each with double ended readout (detailed dimensions on slide 6) • 4 gas volumes . Total active area ~ 8 m2 • Pre-amplification of signals at the detector • Analog signal recorded in FEM ( to be used for slewing corrections). Digitization in FEM J.Velkovska PANIC05

  17. Final detector: mechanics • Checkerboard pattern of MRPC+preamp electronics • optimize active area • Keep the electronics outside the box to limit noise • Fit into 3” of radial space available in PHENIX West arm • The most complicated part Vanderbilt machine shop has ever built J.Velkovska PANIC05

  18. Summary and status • In the period Jan 2004 – Oct 2005 we have gone from conceptual ideas to final detector construction ( help from our STAR colleagues at RICE university is gratefully acknowledged). • A complete detector + electronics chain was successfully operated within PHENIX for 3 months in heavy ion beam conditions in 2005. All design goals were met. • Status today: • All detector modules produced • Extremely tight schedule for electronics production • We expect to install at least half of the full system in 3 weeks • I hope that my next talk will be about physics produced with the new TOF detector ! J.Velkovska PANIC05

More Related