1 / 14

Terminal Learning Objective

Terminal Learning Objective. ACTION: Conduct unmasking procedures. CONDITIONS: Given a group of soldiers at MOPP4 (with M8 detector paper); a simulation describing an area where chemical agents have been used; and one of the following situations:

Télécharger la présentation

Terminal Learning Objective

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Terminal Learning Objective • ACTION: • Conduct unmasking procedures. • CONDITIONS: • Given a group of soldiers at MOPP4 (with M8 detector paper); a simulation describing an area where chemical agents have been used; and one of the following situations: • 1. The M256A1 Chemical Agent Detector Kit is available. 2. The M256A1 Chemical Agent Detector Kit is not available.

  2. Terminal Learning Objective (cont.) • STANDARD: • 1. Conduct unmasking procedures with the M256A1 Chemical Agent Detector Kit without becoming a casualty or allowing any soldier to become a casualty. 2. Conduct unmasking procedures without the chemical agent detector kit exposing no more than two soldiers to possible contamination.

  3. Learning Objective A • ACTION: • Identify the steps to conduct unmasking procedures with the M256A1 Chemical Agent Detector Kit. • CONDITIONS: • Given a group of soldiers at MOPP4, a simulation describing an area where chemical agents have been used, and the M256A1 Chemical Agent Detector Kit is available. • STANDARD: • Identify steps to conduct unmasking procedures with the M256A1 Chemical Agent Detector Kit, without becoming a casualty or having any of your soldiers become a casualty.

  4. Overview of Unmasking Procedures • Conducted after methods of agent detection fail to indicate presence of agents. • Should be conducted as soon as possible to alleviate soldiers’ encapsulation and restore their combat potential. • Two Unmasking Procedures: • With M256A1 Chemical Agent Detector Kit • Without M256A1 Chemical Agent Detector Kit

  5. Overview of Unmasking Procedures (cont.) • Selected soldiers should be disarmed before they unmask. • Should be conducted in shade. Bright, direct sunlight can cause pupils in the eyes to constrict, giving false signs of nerve agent exposure.

  6. Unmasking with the M256A1 Chemical Agent Detector Kit • (1) Senior person present selects one or two soldiers to unmask after permission is received from higher headquarters. • (2) Conduct unmasking procedures in shade. • (3) Use M256A1 Chemical Agent Detector Kit to test for chemical agents. Use M8 Paper to check for liquid contamination. • NOTE: Continue only if both tests come up negative.

  7. Unmasking with the M256A1 Chemical Agent Detector Kit (cont.) • (4) Direct at least two soldiers to unmask for 5 minutes and then don, seal, and clear masks. • (5) Observe these soldiers for 10 minutes for symptoms. • (6) If no symptoms appear, direct all soldiers to unmask.

  8. Unmasking with the M256A1 Chemical Agent Detector Kit (cont.) • (7) Check soldiers for delayed symptoms. Have first aid treatment available. • (8) Complete steps (1) through (7) in sequence. • NOTE: This entire procedure will take approximately 15 minutes.

  9. Learning Objective B • ACTION: • Discuss steps to conduct unmasking procedures without the M256A1 Chemical Agent Detector Kit. • CONDITIONS: • Given a group of soldiers at MOPP4 (with M8 detector paper), a simulation describing an area where chemical agents have been used, and the M256A1 Chemical Agent Detector Kit is not available. • STANDARD: • Identify steps to conduct unmasking procedures without the chemical agent detector kit without exposing no more than two soldiers to possible agents.

  10. Unmasking without M256A1 Chemical Agent Detector Kit • (1) Senior person present selects one or two soldiers to unmask after permission is received from higher headquarters. • (2) Conduct unmasking in the shade. • (3) Use M8 paper to check for possible liquid contamination. • NOTE: Continue unmasking procedures only if test is negative.

  11. Unmasking without M256A1 Chemical Agent Detector Kit (cont.) • (4) Select one or two soldiers to take a deep breath and break the seals of their masks, while keeping their eyes open for 15 seconds; then reseal and clear their masks. • (5) Observe them for 10 minutes for symptoms. • (6) If no symptoms appear, direct these soldiers to break the seals of their masks, take two or three breaths, and then reseal and clear their masks.

  12. Unmasking without M256A1 Chemical Agent Detector Kit (cont.) • (7) Observe them for 10 more minutes for symptoms. • (8) If no symptoms appear, direct these soldiers to unmask for 5 minutes and then don, seal, and clear their masks. • (9) Observe them for 10 minutes for symptoms.

  13. Unmasking without M256A1 Chemical Agent Detector Kit (cont.) • (10) If no symptoms appear, direct all soldiers to unmask. • (11) Check soldiers for delayed symptoms and have first aid available. • (12) Complete steps (1) through (11) in sequence. • NOTE: This entire procedure will take approximately 35 minutes.

More Related