An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB Laboratory of Electrochemistry and PATLAB Raluca-Ioana STEFAN-VAN STADEN WG3 GROUP ON ELECTROCHEMICAL SENSORS & BIOANALYSIS www.patlab.ro

  2. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB INSTRUMENTATION • PGSTAT AUTOLAB: 30, 12, 100; • AUTOLAB ESPRIT SPR • SECM370 SCANNING ELECTROCHEM. MICROSCOPE SYSTEM • SHIMADZU 3600 DOUBLE BEAM UV-VIS-NIR SPECTROPHOTOMETER • PROCESS ANALYZERS

  3. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB INSTRUMENTATION • AGILENT 5500 SERIES AFM/SPM

  4. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB TYPES OF ELECTRODES: - AMPEROMETRIC ELECTRODES; - POTENTIOMETRIC ELECTRODES: ISME, EPME; - SCREEN-PRINTED ELECTRODES; - ENZYME(S) BASED BIOSENSORS; - IMMUNOSENSORS; -STOCHASTIC SENSORS; - SPR SENSORS.

  5. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB

  6. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB Ag/AgCl Modified paste Microsensor design • Constructive characteristics: • Total length of the sensor: • 7.0 0,5 mm; • The diameter of the active side: • 349.69 µm.

  7. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB “No analysis is better than the sample itself.” George - Emil Baiulescu APPLICATIONS: - CLINICAL ANALYSIS; - PHARMACEUTICAL ANALYSIS; - COSMETICS ANALYSIS; - FOOD ANALYSIS.

  8. (1,2-methanofullerene C60)-61-carboxylic acid (I) () S-Dep S-Dep

  9. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB AFM - SURFACE ANALYSIS - immobilization of electroactive component; - understanding of the electrocatalytic process at the membrane/sol. interface; (Anal.Chim.Acta, 668(2010) 201- 207) - explained stochastic behaviour. - CANCER BIOMARKERS

  10. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB STOC - µSENS - CMD EARLY DETECTION OF CANCER A CHANCE FOR LIFE!

  11. Mn(III)TTP Prostate cancer diagnosis

  12. PROCESS ANALYTICAL TECHNOLOGY LABORATORY PATLAB CONCLUSION HEALTHCARE REVOLUTION • Disease management; • Improving of the quality of life; • Life loss avoidance; • Reduce costs. Nano Macro Micro

  13. We are interested in WG3.