An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Food Analysis Lecture 24 (04/23/2013) GC (2) Qingrong Huang Department of Food Science

  2. Sample Injection • Direct Injection • Sample Derivatization

  3. Column • Either packed or capillary column • Packaging Materials: • - Packed column: silane-treated diatomaceous earth • - Capillary column: hollow fused silica glass • Stationary phase: - polysiloxane-based (-Si-O-Si-) • -General rules: choose polar phase to separate polar compounds • and phenyl-based column to separate aromatic compounds.

  4. Detector • Thermal Conductivity Detector (TCD) • Flame Ionization Detector (FID) • Electron Capture (ECD) • Flame Photometric Detector (FPD) • Photoionization Detector (PID)

  5. Carrier Gas • In capillary chromatography, A term is small; • N2 is the most efficient carrier gas, but its minimum occur in low u; • Hydrogen is a better choice than He and N2

  6. SPME • Microextraction technique which employs a thin film of sorptive polymer on a glass fiber • Fiber • Having varying film thickness of polymer • Coatings are based on both absoption and adsorption mechanisms • Convenient, solventless extraction technique • Used to extract analytes from both liquid and solid matrices

  7. SPME Advantages • less solvent required • speed • less glassware is needed • better precision and accuracy • minimal solvent evaporation • readily automated

  8. SPME Device

  9. SPME Procedure Extraction Desorption

  10. Degradation of 2,4-Decadienal • 2,4-Decadienal is an Important Aldehyde Flavor • Contributes Deep Fat Characteristics at 10 ppm • Key Component in Flavors Such as: • Chicken • Lamb • Beef • French Fries

  11. Degradation of 2,4-Decadienal E2,E4-Decadienal Dodecane Freeze Dried → Less Degradation than Spray Dried Red Peaks: Neo FD 60°C 30 Days Blue Peaks: Neo SD 60°C 30 Days Hexanal E2,Z4-Decadienal 2-Octenal Trans-2-Nonenal Limonene Octanoic Acid Hexanoic Acid Methyloctanoate 1-Heptanol

  12. What is citral? Neral Geranial

  13. Citral Degradation Citral . Cyclization (induced by protons) Monoterpene alcohols and more…

  14. Citral Degradation Disappears in TWO weeks! Ueno, T., et al., J. Agric. Food Chem., 2006. 54(8): p. 3055.

  15. Mass Spectrometry

  16. Mass Spectrometry Basics - An analytical tool used for measuring the molecular mass of a molecule • Ionization of molecules; • Separation of ions based on mass-to-charge ratio (m/z); • Detected by mass analyzer under electrostatic field; • Routine in analytical labs; • GC-MS: interface of mass spectrometer with GC; • LC-MS: interface of mass spectrometer with HPLC.

  17. Sample Introduction • Direct Injection: for a gas or a volatile liquid; • Direct Insertion: for somewhat volatile solid, the sample is placed • in a small cup at the end of a stainless steel rod or probe; • For mixtures, we can use GC-MS or LC-MS through an • interface which removes excess GC carrier gas or HPLC solvent.

  18. Ionization • In ion source, the compound is exposed to a beam of electrons • emitted from a filament composed of rhenium or tungsten metal. • When a direct current is applied to the filament (~70 eV), it heats • and emits electrons that move across the ion chamber toward a • positive electrode; • As the electron pass through the source region, they come in close • proximity to the sample molecule and extract an electron, forming • an ionized molecule; • The ionized molecules can further fragment into smaller molecular • fragments.

  19. Ionization Process

  20. Example of Ionization Process

  21. Chemical Ionization (1) • - Chemical Ionization (CI) is especially useful technique when no • molecular ion is observed in EI mass spectrum, and also in the case of • confirming the mass to charge ratio of the molecular ion. • Chemical ionization technique uses virtually the same ion source • device as in electron impact, except, CI uses tight ion source, and • reagent gas. Reagent gas (e.g. ammonia) is first subjected to electron • impact. • Sample ions are formed by the interaction of reagent gas ions and • sample molecules. This phenomenon is called ion-molecule reactions. • -Reagent gas molecules are present in the ratio of about 100:1 with • respect to sample molecules. • -Positive ions and negative ions are formed in the CI process. • -Depending on the setup of the instrument (source voltages, detector, etc...) • only positive ions or only negative ions are recorded.   

  22. Chemical Ionization (2) •   In CI, ion molecule reactions occur between ionized reagent gas molecules • (G) and volatile analyte neutral molecules (M) to produce analyte ions. • Pseudo-molecular ion MH+ (positive ion mode) or [M-H]- (negative ion mode) • are often observed. Unlike molecular ions obtained in EI method, MH+ and • [M-H]- detection occurs in high yield and less fragment ions are observed. • Positive ion mode: (example) • CH4 + e -----> CH4+. + 2e ------> CH3+ + H. • CH4+. + CH4 -----> CH5+ +CH3. • Negative ion mode: (example) • NH3 + e -----> NH3+. + 2e • NH3+. + NH3 ------> NH4+ + NH2.