ICBS Master Panels for Kit Evaluation: HCV, HBV, and HIV (WWW.ICBS-WEB.ORG)

ICBS Master Panels for Kit Evaluation: HCV, HBV, and HIV (WWW.ICBS-WEB.ORG). Howard A. Fields, Ph.D. Susan Diaz, MPH Division of Viral Hepatitis Centers for Disease Control and Prevention. Objective of Master Panels.

ruana
Télécharger la présentation

ICBS Master Panels for Kit Evaluation: HCV, HBV, and HIV (WWW.ICBS-WEB.ORG)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ICBS Master Panels for Kit Evaluation: HCV, HBV, and HIV(WWW.ICBS-WEB.ORG) Howard A. Fields, Ph.D. Susan Diaz, MPH Division of Viral Hepatitis Centers for Disease Control and Prevention

  2. Objective of Master Panels • Identify, validate, and make available high-quality affordable tests for HBV, HCV, and HIV because cost is one of the major impediments to universal screening. • Use as a model for BTEP project to produce Master Panels with Dr. Alexander Kanev, Vector currently in year 3.

  3. HCV Master Panelspositive and negative

  4. HCV Master Panel:Diversity • Country of origin • Genotype • Subtype • RIBA 3.0 banding patterns

  5. * N=14 for HCV some collaborators different for HBV and HIV Location of International HCV Collaborators

  6. Methods to Characterize Panel Members • Screening Tests • Anti-HCV by Ortho 3.0; positives repeated in duplicate • Confirmatory Tests • RIBA 3.0 for HCV by Chiron • Quantitative PCR • Roche Amplicor for HCV RNA • Genotyping / Subtyping by direct DNA Sequencing • CDC: ABI Prism 3100 Capillary Sequencer (NS5b default to 5’-UTR); phylogenetic analysis • Visible Genetics, Inc. Clip Sequencing Reaction for HCV (5’UTR/NS5b) percent homology

  7. Collections • HCV: 1007 • HBV: 450 • HIV: 200 • COINFECTION: 62 • NEGATIVES: 450 • Total Units Received: 2169

  8. HCV Positive UnitsDescription of Selectable Units • Serologically confirmed as positive (exclude indeterminate specimens) • Concordant genotype by direct DNA sequencing from two laboratories • Minimum volume 100 ml • Additional selection criteria based upon diversity • By geographic regions • By genotype/subtype • By RIBA banding patterns

  9. Diversity by Genotype among Selected Units • Among 1007 HCV IR units received and characterized, 539 unitsmet the definition of selectable (54%) • Genotype 1 (n=296) • Genotype 2 (n=26) • Genotype 3 (n=42) • Genotype 4 (n=129) • Genotype 5 (n=3) • Genotype 6 (n=43)

  10. 66 23 40 36 3 32 Diversity by subtype RIBA 3.0 banding patterns Diversity by Country and Genotype among Official HCV Panel Members

  11. Negative Panelgeographic diversity • Manufacturing completedJune 18, 2002 • First panel to be completed • 200 Members from both thedeveloped and developing world • 181 domestic members utilized from ARC • 19 members pooled by region: Egypt, Indonesia, and Ivory Coast

  12. Origin of Kits Sent to PEI • China 13 • Russia 9 • India 7 • South Korea 5 • EU 4 • Costa Rica 1 • Indonesia 1 • Uzbekistan 1 • Brazil 1 • Argentina 1 • USA (not FDA approved) 1 Total = 44

  13. Russian Kits Sent to PEI for Evaluation • Biotechnologitzeskaja Kompanija Bioservis (No. 23, Hepascreen) • IMBIO (No. 24, Anti-HCV ELISA) • Medizinische Biologische Union (No.27, HCV-DCM) • Union–Diagnostisches-System (No.25, Anti-HCV ELISA) • Vector-Best (No. 29, RecombiBest anti-HCV-Strip, OPD) • Received, but Not Evaluated as of August 23, 2004 • Institut Pastera Sankt-Peterburg (Anti-HCV ELISA-G) • NPP Akwapast (Immunoenzyme Test-System for Detection of Anti-HCV) • Radiopreparat (Anti-HCV) • Vector-Best (RocombiBest anti-HCV-Strip, TMB)

  14. Specimens • ICBS HCV Master Panel (n=200) • ICBS negative Master Panel (n=181 and 200) • Seroconversion Panel (commercial) • core only, genotype 2b • NS3 only • Core & NS3, genotype 1a • Mean day delay

  15. ^ ^ ^ ^ ^ * * * * * ^ Russian kits * Significant reduction in specificity (n = 181 vs. 200)

  16. * * * * * ^ ^ ^ ^ ^ ^ Russian kits * Significant reduction in specificity (n = 181 vs. 200)

  17. * * PI of Russian Kits Evaluated PI • Union–Diagnostisches-System235.28 232.83 • Biotech Kompanija Bioservis235.00 231.00 • IMBIO 232.83 232.33 • Vector-Best 231.78 229.83 • Medizinische Biolog Union 231.28 229.30 N=181 N=200 * Statistical significant reduction in specificity (n = 181 vs. 200)

  18. Conclusions (1) • ICBS HCV Negative Master Panel manufactured June, 2002. • N = 181 US specimens • N =19 specimens from the developing world yielded weaklyscreening test positive when tested with some assays licensed in the EU. Some specimens also tested positive/indeterminate with some of the EU license supplemental tests. • N = 200 specimens confirmed as true negative at CDC(Ortho 3.0, Chiron RIBA 3.0, and Roche HCV Amplicor)

  19. Conclusions (2) • ICBS HCV Positive Master Panel manufactured September, 2002 • Diversity based on geographic origin, genotype, subtype (concordance by DNA sequencing), and RIBA 3.0 banding patterns • All confirmed as true positive by screening (Ortho 3.0), supplemental testing (RIBA 3.0), and positive PCR (Roche HCV Amplicor)

  20. Conclusion (3) • Russian kits evaluated by PEI 2003 – 2004 • PI less than kits licensed in the US and EU and several other kits manufactured in resource-challenged regions of the world • Highest PI manufactured by Union–Diagnostisches-Systemprobably equal to the kit manufactured by Biotech Kompanija Bioservisbased on 181US specimens • When 19 specimens from the developing world was added (n=200), the specificity of all 5 Russian kits decreased; however, only kits Union–Diagnostisches-System and Biotechnologitzeskaja Kompanija Bioservis decreased to a statistical significant level. • Despite this decrease in specificity, the kit manufactured by Union–Diagnostisches-System continued to have the highest PI value among the Russian kits evaluated.