An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Session 6 Summary 5 presentations • Youchison: ITER FWQM testing – described HHF testing for the completed round 1 testing of EU&US FW mock-ups (12000 cycles at .875 MW/m2, 1000 cycles at 1.4 MW/m2, 100 cycles at 2.2 MW/m2). Round 2 with CN,JA,KO, & RF mock-up now at 6300 cycles at .875 MW/m2. Round 2 testing will continue through end of August. Parallel testing at Besthe facility in EU.

  2. Youchison: Two-phase CFD analysis of FW hypervapotrons for ITER. Evaluated two commercial CFD codes for applicability to this problem. • Fluent had problems with solver divergence. Star-CCM+ gave stable results and works with native Catia files. Benchmarking experiments now in planning. • Boyd: Summary of peaking factor correlation development work at Prairie View A&M. Methodology for PF development (e.g. swirltube monoblock). Studies for geometry changes such as wall thickness on peaking factors (passive high heat flux enhancement). Produce a quick scoping tool for evaluation of PFC cooling concepts. • Morley: Presented CFD analysis of ITER baseline FW/SM design by Alice Ying et al. 3-d flow and conjugate heat transfer analysis on full BSM04. Comparison to alternate concepts – illustrated problems with ITER CAD models. Presneted thermal analysis on hypervapotron including Be tiles using boiling correlation. 5 Mw/m2 over one tile results in Be evaporation. • Morley: Presented MHD analysis of thermocapillary transport of Li using HIMAG code and 1-D model from UIUC. Also began analysis of thermoelectric MHD transport to explain UIUC SLiDE experiment. Presented CVD SiC/Ga compatability up to 700C, 24 hours – 6mg loss from 806mg SiC. Discussed Be/F82H joining development work for ITER TBM.

More Related