CONCEPTUL DE DOZA INDIVIDUALA NEGLIJABILA IN RADIOPROTECTIE

CONCEPTUL DE DOZA INDIVIDUALA NEGLIJABILA IN RADIOPROTECTIE Anton Coroianu, Mircea Tudor, Constantin Sima MB Telecom-Ltd. SRL, Calea Bucurestilor nr. 3A, Otopeni anton.coroianu@mbtechnology.ro, mirceat@mbtechnology.ro, costel.sima@mbtechnology.ro

sachi
Télécharger la présentation

CONCEPTUL DE DOZA INDIVIDUALA NEGLIJABILA IN RADIOPROTECTIE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CONCEPTUL DE DOZA INDIVIDUALA NEGLIJABILA IN RADIOPROTECTIE Anton Coroianu, Mircea Tudor, Constantin Sima MB Telecom-Ltd. SRL, Calea Bucurestilor nr. 3A, Otopeni anton.coroianu@mbtechnology.ro, mirceat@mbtechnology.ro, costel.sima@mbtechnology.ro Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  2. Conceptul de doza individuala neglijabila (Negligible Individual Dose - NID) anuala a fost stabilit inca din anul 1993 de catre National Council on Radiation Protection and Measurements (NCRP) din SUA la valoarea anuala de 0,01mSv (10µSv) doza efectiva. Valoarea anuala de 10µSv este considerată un NID pe sursa sau practica. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  3. Definitia originala este “NID is an effective dose corresponding to the level of average annual excess risk to fatal health effects attributable to radiation below which an effort to reduce the radiation exposure to an individual is not warranted”. Acest concept ia in considerare faptul ca variatia aleatoare a riscului datorat tuturor cazurilor altele decat radiatia este mult mai mare decat incremental cresterii riscului datorat NID-ului. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  4. Principiul “low individual risk” (LIR) a fost introdus in radioprotectie de catre NEA si IAEA din 1988 odata cu primele ghiduri de principii de exceptare a surselor de radiatii si a practicilor de la reglementare si control ca o doza corespunzatoare unui nivel de risc care nu are semnificatie asupra individului, luand ca referinta relevanta fondul natural de radiatii. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  5. Concluzia a fost ca o doza de radiatii individuala, indiferent de originea sa, este probabil sa fie considerata ca fiind nesemnificativa daca este de ordinul a cateva zeci de µSv pe an. S-a observat ca acest nivel de doza corespunde catorva procente din limita de doza anuala recomandate de ICRP pentru membrii din public. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  6. Aceasta doza banala, nesemnificativa, denumita “trivial individual dose” (TID) trebuie sa asigure un risc anual de deces mai mic de 10-6 pana la 10-7, care este considerat a nu asigura nici un motiv de ingrijorare pentru individ, valoare mult redusa fata de 10-5 pentru alte activitati nenucleare. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  7. Considerand un factor de risc de circa 5 x 10-2/Sv (BEIR VII - NAS/NRC - 2006) pentru expunerea intregului corp se ajunge la un nivel al TID cu o magnitudine de 10 - 100µSv/an. Deci NID de 10µSv/an asigura un risc anual de deces de 10-7. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  8. Valoarea anuala a dozei individuale datorate fondului natural de radiatii este de circa 2mSv. Aceste valori sunt datorate materialelor radioactive din sol, din materialele de constructii, diferentelor de altitudine, stil de viata, radiatiilor cosmice, radionuclizilor din corpul uman, sunt practic incontrolabile si variaza semnificativ. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  9. Membrii individuali din public, in general nu tin cont de variatia expunerii la fondul natural de radiatii atunci cand se deplaseaza dintr-o parte a tarii in alta sau cand merg in vacanta. Se estimeaza ca o doza de 20-100µSv/an, este banala respectiv nesemnificativa si ea reprezinta o variatie minima de 1-5% ale expunerii individuale datorate fondului natural de radiatii. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  10. Din aceste considerente valoarea de 10µSv/an este o TID respective NID care are un risc individual scazut (LIR), am spune nesemnificativ, valoare care este sub 0,5% din doza datorata fondului natural de radiatii, mult sub variatia acestuia, valoare sub care practicile sau sursele pot fi exceptate (ICRP 104, 4.1.1, 2007) Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  11. NID a fost introdus in Basic Safety Standards (BSS, IAEA, 1996) cu definitia din Schedule I, para. I-3 „A practice or source within a practice may be exempted without further consideration provided that…. the effective dose expected to be incurred by any member of the public to the exempted practice or source is of the order of 10µSv or less in a year”. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  12. Directiva 96/29 EURATOM preia valoarea NID de 10µSv/an pentru doza efectiva in Anexa 1, 3a pentru conditiil de exceptare a practicilor. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  13. Normele Fundamentale de Securitate Radiologica (NSR-01) aprobate prin Ordinul Presedintelui CNCAN Nr. 14/2000 transpune partial Directiva 96/29 EURATOM si utilizeaza, suplimentar fata de directiva, valoarea NID de 10µSv in Anexa 2 punctul 2 la stabilirea nivelurilor de excludere pentru 298 de radionuclizi prezenti in Tabelul 2-B col. 2 deduse in ipoteza ca ingestia unui kg de material va duce la o doza eficace angajata de 10µSv. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  14. De asemenea la pct. 7 a) din aceeasi anexa, NID este utilizata ca o conditie de exceptare a unei practici fara o evaluare suplimentara. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  15. Normeleprivindeliberarea de subregimul de autorizare a materialelorrezultatedinpracticiautorizate (NDR-02) au NID, respectivnivelul de excluderedin NSR-01 dreptcriteriu de eliberareneconditionata. ConferintaNationala a SocietatiiRomane de Radioprotectiesi a SocietatiiRomane de MedicinaMuncii Bucuresti, 08.10.2010

  16. In concluzie NID este o valoareuzuala de baza in radioprotectie, valoare ce asigura un LIR sub 1% fata de celelalteactivitatiumanenenucleare si pentru care masurisuplimentare de radioprotectie nu suntrationale. ConferintaNationala a SocietatiiRomane de Radioprotectiesi a SocietatiiRomane de MedicinaMuncii Bucuresti, 08.10.2010

  17. Pe considerentele similare LIR respectiv NID s-a stabilit si doza anuala pentru persoane din populatie la 1mSv, cu un risc echivalent (10-5) altor activitati umane. NID a fost utilizat ca referinta in o serie de standarde nationale din care amintim ANSI N.43.17/2009. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  18. Bibliografie (1): • IAEA,1998. Principles for the Exemption of Radiation Sources and Practices from regulatory Control. Safety Series 89. International Atomic Energy Agency, Vienna. • IAEA, 1996. International Basic Safety Standards for Protection Against Ionising Radiation and for Safety of Radiation Sources. Safety Standards, Safety Series 115. International Atomic Energy Agency, Vienna. • EU, 1996. Directives of the Council of the European Union. 96/29/EURATOM Oficial Journal of the European Commission No. L. 159. Luxemburg. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  19. Bibliografie (2): • NCRP COMMENTARY No. 16. National Council on Radiation Protection and Measurements, Bethesda, Maryland, USA, Dec. 15, 2008. • ICRP, 2007. The 2007 Recommandations of the International Commission on Radiological Protection, ICRP Publication 103. • ICRP, 2007. Scope of Radiological Protection Control Measures. ICRP Publication 104. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010

  20. Bibliografie (3): • United States 2008. Guidance for Security of Humans Utilizing Ionising Radiation, Interagency Steering Committee on Radiation Standards. ISOCOR S Technical Report 2008-1, July 2008. • ANSI, 2004. Radiation Safety for Personnel Security Screening Systems Using X-Ray or Gamma Radiation, American National Standards. Aug. 2009. Conferinta Nationala a Societatii Romane de Radioprotectie si a Societatii Romane de Medicina Muncii Bucuresti, 08.10.2010