1 / 18

COST EFFECTIVE SOLUTION TO REDUCING YOUR ENERGY BILL’S

POWER MASTER. COST EFFECTIVE SOLUTION TO REDUCING YOUR ENERGY BILL’S. POWER MASTER. Reduces Energy Consumption Lowers Demand Charges Saves 10-25% on your electric usage. UNDERSTANDING POWER FACTOR. The horse pulling the railroad car down the track is the working (REAL) power. .

salaam
Télécharger la présentation

COST EFFECTIVE SOLUTION TO REDUCING YOUR ENERGY BILL’S

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. POWER MASTER COST EFFECTIVE SOLUTION TO REDUCING YOUR ENERGY BILL’S Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-503-1873

  2. POWER MASTER Reduces Energy Consumption Lowers Demand Charges Saves 10-25% on your electric usage Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-503-1873

  3. UNDERSTANDING POWER FACTOR The horse pulling the railroad car down the track is the working (REAL) power. Direction of travel The effort of the horse is the total (APPARENT) power. The sideways pull of the horse is wasted effort or nonworking (REACTIVE) power.

  4. Power Factor-NON Optimized REACTIVE POWER KVAR 25% HIGH DEMAND CHARGES APPARENT POWER (KVA) @ 70% WASTED POWER REAL POWER KW (Efficiency 100%)

  5. Targeted Power Factor APPARENT POWER (KVA) (Goal is to achieve efficiency of 95%) REACTIVE POWER KVAR (Efficiency of 1) REAL POWER KW RESULTS IN LOWERS DEMAND CHARGES

  6. Not A New Sciencebut improved science through Micro Processing Technology Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  7. Micro Processors with Capacitors • Reclaim, store, and supply power to inductive motors and loads • Induction loads consume two kinds of power • Reactive power’s function is to develop the electromagnetic fields to ground the induction windings of the motor • Working power (kilowatts) performs the real work of the motor

  8. Micro Processors with Capacitors • Capacitors store the reactive power needed to create the electromagnetic fields within the inductive loads such as motors • Reactive power is pulled and pushed to and from the PowerMaster Controller by the motors

  9. POWER MASTER Benefits • Reactive power is reclaimed and recycled • Reduces demand charges • Real time adjustment to smooth peak loads • Savings up to 10-20%

  10. POWER MASTER Benefits • Longer equipment life • Protects against surges & spikes • Reduces line losses • Decreases voltage drop • Controls harmonic distortion Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  11. HARMONICS Distorted Sine Wave Normal Sine Wave Power Factor of 75% Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  12. Efficency before & after Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  13. Kilowatt Hour Reduction Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  14. Electric Bill Savings Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  15. INSTALLED COMMERCIAL ACCOUNTS Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  16. INSTALLED COMMERCIAL ACCOUNTS Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  17. Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-544-7090

  18. NEXT STEP-ELECTRIC USAGE ANALYSIS Power Master, LLC, 2040 E. Ridge Rd, Rochester, NY, 14622, 585-503-1873

More Related