1 / 15

IX. Transient Model Sensitivity Analysis

IX. Transient Model Sensitivity Analysis. Sensitivity Analysis for the Initial Model. One-percent sensitivities : Can be explained using principle of superposition. Flow budget for simulation with pumping only:. Sensitivity Analysis for the Initial Model.

saul
Télécharger la présentation

IX. Transient Model Sensitivity Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IX. Transient ModelSensitivity Analysis

  2. Sensitivity Analysis for the Initial Model • One-percent sensitivities: Can be explained using principle of superposition. • Flow budget for simulation with pumping only:

  3. Sensitivity Analysis for the Initial Model • DO EXERCISE 9.6a: Evaluate one-percent scaled sensitivity maps for the transient flow system. • One-percent scaled sensitivities for the full transient problem are shown for selected parameters in Figures 9.6 to 9.8 of Hill and Tiedeman. • One-percent scaled sensitivities for the pumping only simulation are shown for selected parameters in Figures 9.9 to 9.10.

  4. One-Percent Sensitivities for HK_1 Figure 9.6 of Hill and Tiedeman

  5. One-Percent Sensitivities for HK_1: Flow System with Pumping Only (No Recharge) Figure 9.9 of Hill and Tiedeman

  6. One-Percent Sensitivities for HK_1 (at 4 days): Calculating Using Superposition

  7. One-Percent Sensitivities for HK_1 (at 283 days): Calculating Using Superposition

  8. One-Percent Sensitivities for HK_1: Understanding Using Darcy’s Law • Flow system with pumping only,at early time • Main source of water to well is water released from storage in vicinity of well. When HK_1 is increased, the gradient towards the well needs to decrease in order to maintain similar amount of flow to the well through layer 1.

  9. One-Percent Sensitivities for HK_1: Understanding Using Darcy’s Law • Flow system with pumping only,at later time • Main source of water to well is inflow from river. When HK_1 is increased, the gradient from the river towards the well needs to decrease in order to maintain similar amount of flow to the well through layer 1.

  10. One-Percent Sensitivities for K_RB (at 58 days): Calculating Using Superposition

  11. One-Percent Sensitivities for K_RB: Understanding Using Darcy’s Law • Recap: Flow system with recharge only • Increase K_RB, hydraulic gradient across riverbed must decrease to maintain same discharge to the river. In the system with recharge only, h > Hriv; therefore, h must decrease when K_RB increases

  12. One-Percent Sensitivities for K_RB: Understanding Using Darcy’s Law • Flow system with pumping only • Reason that heads increase in response to an increase in K_RB:Increase K_RB, hydraulic gradient across riverbed must decrease to maintain similar inflow to the aquifer. In the system with pumpage only, h < Hriv; therefore, h must increase when K_RB increases. • Reason for slight increase in hydraulic gradient away from the river:An increase in K_RB causes a slight increase in Qriv and a slight decrease in Qstorage. The increased gradient is needed for this increased river water to flow to the well.

  13. Sensitivity Analysis for the Initial Model • DO EXERCISE 9.6b: Use composite scaled sensitivities to evaluate the information provided by observations for the defined parameters. • Composite scaled sensitivities for the starting parameter values are shown in Figure 9.11 of Hill and Tiedeman. • DO EXERCISE 9.6c: Evaluate parameter correlation coefficients to assess parameter uniqueness . • The parameter correlation coefficient matrices for the starting parameter values for the transient problem, calculated using MODFLOW-2000, are shown in Table 9.5.

  14. Composite scaled sensitivities at the starting parameter values for the transient problem Figure 9.11 of Hill and Tiedeman (page 243)

  15. Q_1&2 SS_1 HK_1 K_RB VK_CB SS_2 HK_2 RCH_1 RCH_2 Q_1&2 1.00 -0.91 -0.99 -0.057 -0.67 -0.41 -0.96 -0.66 -0.83 SS_1 1.00 0.88 -0.078 0.80 0.043 0.89 0.58 0.75 HK_1 1.00 -0.029 0.68 0.41 0.92 0.67 0.82 K_RB 1.00 -0.36 0.38 0.22 0.051 0.055 VK_CB 1.00 -0.23 0.61 0.43 0.55 SS_2 symmetric 1.00 0.41 0.30 0.35 HK_2 1.00 0.62 0.81 RCH_1 1.00 0.16 RCH_2 1.00 Parameter correlation coefficients at the starting parameter values for the transient problem Table 9.5 of Hill and Tiedeman (page 244)