1 / 16

Effect of Input Rate Limitation on Controllability

Effect of Input Rate Limitation on Controllability. Presented at AIChE Annual Meeting in Austin, Texas November 7 th , 2002 Espen Storkaas & Sigurd Skogestad Presented by Federico Zenith Department of Chemical Engineering, Norwegian Unviversity of Science and Technology. Pressure set point.

shea
Télécharger la présentation

Effect of Input Rate Limitation on Controllability

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Effect of Input Rate Limitation on Controllability Presented at AIChE Annual Meeting in Austin, Texas November 7th, 2002 Espen Storkaas & Sigurd Skogestad Presented by Federico Zenith Department of Chemical Engineering, Norwegian Unviversity of Science and Technology

  2. Pressure set point PC Anti Slug Control Measured pressure at riserbase PT Topside Choke valve Wells • Unstable flow in multiphase pipeline-riser systems for offshore oil production stabilized by pressure controller • How fast must be the topside choke valve (actuator) be? • Slow for safety reasons • Fast for control Subsea choke

  3. Outline • Motivation • Controllability analysis with input rate limitation • Required input rates for: • Stabilization • Disturbance rejection and set point tracking • Controller design with input rate limitations

  4. Controllabilty analysis • Definition (Skogestad & Postlethwaite (1996)) (Input-output) controllability is the ability to achieve acceptable control performance; that is, to keep the outputs (y) within specified bounds or displacements form their references (r), in spite of unknown but bounded variations, such as disturbances (d) and plant changes, using available inputs (u) and available measurements (ym or dm). • Controllability is independent of the controller, and is a property of the plant or process itself

  5. Effect of input limitations • Open-loop unstable systems: • Input saturation breaks feedback loop • Stabilizing effect ruined • Critical • Open-loop stable systems: • Input saturation limits performance • Good theoretical foundation for magnitude saturation • Here: Extend theory to cover rate limitations on actuator • Input rate limitation du/dt · • Actuator from u=-1 to u=1 in 2/ sec u(from controller) u(to process) -1· u · 1 Magnitude limitation du/dt · Rate limitation

  6. Effect of input rate limitations • Sinusoids with frequency  through rate limiter, rate limited to be less than : =p/2 =p = Dashed lines are input (controller output), solid lines are outputs from rate limiter

  7. Bound on available input • Maximal slope for u(t)=|u(j)|¢sin(t) at t=0: • Rate limitation du/dt · , |u(j)| ·/ • Magnitude limitation |u(j)|· 1 • Alternative: • |u|<1 (magnitude)

  8. Input rates for stabilizing control d · 1 Gd(s) + y u K(s) G(s) + • For any unstable pole p (Havre & Skogestad, 2001), • Magnitude saturation (|u| · 1): • Rate saturation (|su(s)| · ):

  9. d + u y + Magnitude Limiter Rate Limiter du/dt · Example 1 – Stabilization • Perfect disturbance rejection: • OK! • fsda

  10. Input rates for perfect and acceptable control • Perfect control: |u |= |G-1Gd|¢|d| • Input limitation requires • (magnitude limitation) • (rate limitation) • Acceptable control (|e|=1): |u|=|G-1|(|Gd|¢|x|-1) • (magnitude limitation) • (rate limitation) • Set point tracking: R instead of Gd

  11. Example 2 – Disturbance Rejection d • Perfect disturbance rejection: • OK! • fsda • Acceptable disturbance rejection: ¸ 0.12 sec-1 + u y + Magnitude Limiter Rate Limiter du/dt·

  12. Achievable bound on input • Exact bound has infinite-dimensional representation in frequency domain • Cannot be used in direct controller design • Bound approximated by 1st order lag filter:

  13. Required input rates using approximate bound on input • Stabilization: • Perfect disturbance rejection: • New limit for example 1: ¸ 0.4 sec-1 (0.22 sec-1 with exact bound) • New limit for example 2: ¸ 1.02 sec-1 (1 sec-1 with exact bound)

  14. d Controller design + y u + • H1 design with minimum input rate (minimize WuKSGd): K(s) p

  15. Simulation • Disturbance with magnitude 1 and frequency p:

  16. Conclusions • Limitation on input rate can limit performance for control systems • Explicit lower bounds on required input rate derived • Stabilization • Disturbance rejection and set point tracking • Controller design with limited input rates