1 / 13

Fluxes and timing in the CNGS muon pits A. Ferrari P. Sala

Fluxes and timing in the CNGS muon pits A. Ferrari P. Sala. Geometry. BLMs. Here: pit1. (pit2 is the same) . Approximated layout of detectors: ( the timing results are not affected by 2 nd order details) supports: 3 mm Al plates, in front and behind diamonds

shiela
Télécharger la présentation

Fluxes and timing in the CNGS muon pits A. Ferrari P. Sala

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fluxes and timing in the CNGS muon pitsA. FerrariP. Sala

  2. Geometry BLMs • Here: pit1. (pit2 is the same) . Approximated layout of detectors: • ( the timing results are not affected by 2nd order details) • supports: 3 mm Al plates, in front and behind diamonds • Detectors: 100μm C density 3.52 • Two positions : • Detector1 at 10 cm from the pit entrance wall, • Detector2 just before the BLMs Detector 1 Concrete Detector 2 beam Beam dump Air of pit 1 325 cm 5 m

  3. Spectra in 1st pit Lethargy spectra of muons and background particles Dominant bg: electrons and photons

  4. Spectra in pit 2 Pit 2, same structure. Backgr. Is regenerated by muons ( hadrons and neutrons via photonuclear reactions)

  5. MUONS spatial distributions pit1 pit2

  6. Electron spatial distr. pit1 pit2

  7. Photon spatial distribution pit1 pit2

  8. Pit 1 (det 1): energy dep. vs time Log-y scale! Full range : 250 ns Position of small secondary peaks consistent with reflections in the pit

  9. Pit 1 (det 2): energy dep. vs time Log-y scale! Full range : 250 ns

  10. Pit 1 (det 2): energy dep. vs time Extended time interval Full range :5 μ s

  11. Pit 2 (det 1): energy dep. vs time Log-y scale! Full range : 250 ns

  12. Pit 2 (det 2): energy dep. vs time Log-y scale! Full range : 250 ns

  13. Pit 1: det 1 vsdet 2 Each x-axis division is 5 ns long

More Related