Commissioning In Mississippi

Commissioning In Mississippi. September 29, 2011. Some Preliminary Stuff. I Don’t Speak “Engineer” As Well As I Used To. Stop Me When You Want More Details. I Don’t Lecture We Talk Questions???. Why Should You Listen To Me?. We All Are Products Of … Our Heredity Our Environment

shilah
Télécharger la présentation

Commissioning In Mississippi

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Commissioning In Mississippi September 29, 2011

  2. Some Preliminary Stuff • I Don’t Speak “Engineer” As Well As I Used To. Stop Me When You Want More Details. • I Don’t Lecture • We Talk • Questions???

  3. Why Should You Listen To Me? We All Are Products Of … • Our Heredity • Our Environment • Our Life Experiences • A Person’s Background Matters • We Must All Understand People To Understand The Decisions They Make

  4. Why Should You Listen To Me? A Short History

  5. Why Should You Listen To Me? A Short History

  6. Why Should You Listen To Me? A Short History

  7. Why Should You Listen To Me? A Short History

  8. Why Should You Listen To Me? A Short History

  9. Why Should You Listen To Me? A Short History

  10. Why Should You Listen To Me? A Short History

  11. Why Should You Listen To Me? A Short History

  12. Why Should You Listen To Me? A Short History

  13. Why Should You Listen To Me? A Short History

  14. Why Should You Listen To Me? A Short History

  15. Why Should You Listen To Me? A Short History, continued

  16. Why Should You Listen To Me? A Short History, continued

  17. Why Should You Listen To Me? A Short History, continued

  18. Why Should You Listen To Me? A Short History, continued

  19. Why Should You Listen To Me? A Short History, continued

  20. Why Should You Listen To Me? A Short History, continued

  21. Why Should You Listen To Me? A Short History, continued

  22. Why Should You Listen To Me? A Short History, continued

  23. Why Should You Listen To Me? A Short History, continued

  24. Why DOES Mississippi Commission? • Building Disasters • Successes Don’t Change Policy • Disasters Do • Executive Sponsorship • Hoopy Stringer • David Anderson

  25. Why DOES Mississippi Commission? The Tipping Point – A Major Building At A University Competent Architect Competent Contractor Supportive Using Agency Competent BoB Staff Additional Field Supervision A Recipe For Success?

  26. Why DOES Mississippi Commission? The Tipping Point – A Major Building At A University An Unmitigated Disaster!!!!! Roof Leaked For 10 Years Walls Leaked For 10 Years Bathroom Exhaust Fan Fell From Ceiling Onto President’s Lap Mold Was Rampant

  27. Why DOES Mississippi Commission? The Tipping Point – A Major Building At A University An Unmitigated Disaster!!!!! ALL Exterior Masonry Removed & Replaced The State Spent A Lot Of Money Lawyers Got A Lot Of Money I Became Good Friends With The Second Architect

  28. Why DOES Mississippi Commission? The Tipping Point – A Major Building At A University What Went Wrong? Pretty Much Everything No One Looked At The Big Picture No One Nagged No One Tattled

  29. Mississippi Valley State University Sutton Hall Administration Building Repairs

  30. Sutton Hall Administration Repairs

  31. Sutton Hall Administration Repairs

  32. Sutton Hall Administration Repairs Process Investigation and Forensic Analysis of the existing building envelope. Mitigation Vacating and relocation of building occupants. Repair Documents Bidding Construction Administration.

  33. Sutton Hall Administration Repairs Key Factors Insufficient Air Space No Air/Weather Barrier Compromised Exterior Sheathing Missing or Poorly Installed Rigid Insulation Insufficient Masonry Ties and Reinforcing Mold and Mildew Missing Fire Sprinkler System Problematic HVAC System and Plenum Return

  34. Sutton Hall Administration Repairs Investigation and Forensic Analysis Saw cutting and removal of portions of brick.

  35. Sutton Hall Administration Repairs Investigation and Forensic Analysis Completed patching of forensic openings.

  36. Sutton Hall Administration Repairs Repair Documents View of scaffolding.

  37. Sutton Hall Administration Repairs Construction Administration View of scaffolding and weather membrane.

  38. Sutton Hall Administration Repairs Construction Administration Pryor & Morrow marks walls to be repaired with the contractor.

  39. Sutton Hall Administration Repairs Construction Administration Exterior Envelope has been removed and Forensic Analysis continues.

  40. Sutton Hall Administration Repairs Construction Administration

  41. Sutton Hall Administration Repairs Construction Administration

  42. Sutton Hall Administration Repairs Construction Administration

  43. Sutton Hall Administration Repairs Construction Administration

  44. Sutton Hall Administration Repairs Construction Administration

  45. Sutton Hall Administration Repairs Construction Administration

  46. Sutton Hall Administration Repairs Construction Administration

  47. Sutton Hall Administration Repairs Construction Administration Construction of new parapet walls.

  48. Sutton Hall Administration Repairs Construction Administration Original Boiler Flue Construction. Original Boiler Flue Penetration Design.

  49. Sutton Hall Administration Repairs Construction Administration How it was built… Revised Detail.