An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Multi-Bunch Options for LCLS Ability for changes during RF pulse Franz-Josef Decker 19-Oct-2001

  2. From previous talks: • Multi-Bunch Operation for LCLS March 17, 2010 • Two-Bunch Test with LCLS Lasing July 29, 2010 • Multi-Bunches for the LCLS April 18, 2011 • all at: V:\AD\Drop Boxes\Decker\Drop\LCLS

  3. What Can the Accelerator Do? • Bunches with the same parameters: • Charge, energy, bunch length, … • Spacing from 0.35 ns (RF) to 400 ns • Bunches with different parameters: • Difference is dependant on bunch spacing: • Energy change: E  10 MeV/ns • Peak current:  80 A/ns • Bunches can have different charge: 250 pC + 20pC

  4. SLAC LINAC Experience with Multi-Bunch Operations • SLC: 3 bunches, 60 ns apart, 7000 pC • E158: 1000 bunches, 350 ns long, 100 pC • E155: 1400 bunches, 500 ns long, 0.3 pC 15% energy variation  0.1% • LCLS multi-bunch range: 2-50 bunches, 0.35 – 400 ns, 20-500 pC Energy spread Energy

  5. Accelerator Issues for LCLS • Two drive lasers at gun • allow variable time delays, 4*150 pC or 8*80 pC or 16*40 pC • Accelerating field varies over 400 ns pulse • affects energy, compression, beam trajectory • Bunches affect each other • wakefields: energy, compression, beam trajectory • Diagnostics not fast enough yet • Individual control of bunches not trivial • some experience at SLAC • Dump power limit (5 kW): 12 bunches, 250 pCeach

  6. LCLS Multi-Bunch Correction Schemes • Energy compensating was done sector by sector (100m) • one low-energy sector compensated four high-energy sectors, this non-local correction causes different beam trajectories • Fast kickers required at undulator entrance • Special RF sections Gun, L0, L1S, L1X need waveform modifications • L2 needs fast phase control to adjust compression Normal Energy Gain Curve Maximum variation 400 ns

  7. RF Phase Manipulation • SLC 1990: 6.8 in 60 ns in NRTL LCLS 2009: 4.0 difference between over- and under-compression in L2 with SLED: 1/2 at input (1/3 at output) and 800ns fill time (600 ns NRTL): we need about 100 ns for 4 change

  8. Tools we used • SLED RF timing and 180 for energy change: • PSK2_L2 and PSK2_L3 for Two-Bunch Test (LCLS) • Additional PSK pulse(s) 180(“SLEDF “ triggers for E-155) • +/- 90  for phase change: • 90 ”Judkin box” for NRTL compressor (SLC) now at CID (?)

  9. Tools we need • L3: E (PSK2_L3) on-off-time, need 180 for more change • L3: phase not necessary • L2: E (PSK2_L2) on-off-time is enough to keep BC2 E • L2: phase is necessary: 90 to change chirp • L1: L1S and/or L1X control is there (I/Q waveform), but changing the waveform files is lengthy (no easy knob) not SLEDed (there was a small difference after BC1) • Gun, L0A, L0B same with waveforms • Fast kickers required at undulator entrance 500V to strip-line • Two injector lasers and/or split and delay