1 / 11

Composite Amplifier Stability Analysis First Scheme & Second Scheme

Composite Amplifier Stability Analysis First Scheme & Second Scheme. Tim Green, MGTS Precision Linear Analog Applications August 7, 2014. First Scheme - Loop Gain Op Amp U1. Run DC Operating Point first to be sure all op amp inputs and outputs are in the linear region of operation.

shill
Télécharger la présentation

Composite Amplifier Stability Analysis First Scheme & Second Scheme

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Composite Amplifier Stability AnalysisFirst Scheme & Second Scheme Tim Green, MGTS Precision Linear Analog Applications August 7, 2014

  2. First Scheme - Loop Gain Op Amp U1 Run DC Operating Point first to be sure all op amp inputs and outputs are in the linear region of operation. Otherwise AC Analysis is not valid if op amp outputs are saturated or common mode inputs violated.

  3. First Scheme - Loop Gain Op Amp U1 Loop Gain Phase Margin = 68.9deg

  4. First Scheme - Loop Gain Op Amp U2 Run DC Operating Point first to be sure all op amp inputs and outputs are in the linear region of operation. Otherwise AC Analysis is not valid if op amp outputs are saturated or common mode inputs violated.

  5. First Scheme - Loop Gain Op Amp U2 Loop Gain Phase Margin = 77.1deg

  6. First Scheme - Loop Gain Op Amp U2 Loop Gain Phase Margin = 77.1deg

  7. Second Scheme - Loop Gain Op Amp U1 Run DC Operating Point first to be sure all op amp inputs and outputs are in the linear region of operation. Otherwise AC Analysis is not valid if op amp outputs are saturated or common mode inputs violated.

  8. Second Scheme - Loop Gain Op Amp U1 Loop Gain Phase Margin = 69.9deg

  9. Second Scheme - Loop Gain Op Amp U2 Run DC Operating Point first to be sure all op amp inputs and outputs are in the linear region of operation. Otherwise AC Analysis is not valid if op amp outputs are saturated or common mode inputs violated.

  10. Second Scheme - Loop Gain Op Amp U2 Loop Gain Phase Margin = 62.5deg

  11. All Embedded Schematics in this presentation can be run in the Free TINA_TI SPICE simulator available at: http://www.ti.com/tool/tina-ti