1 / 14

High-Energy Ground Level Events Measured with Neutron Monitors and the Milagro Instrument

This research investigates high-energy ground level events using neutron monitors and the Milagro instrument. Data from various locations and altitudes are analyzed to study the solar particle spectrum and identify potential sources of TeV gamma-ray emissions. The study also discusses the challenges in understanding the acceleration process and the need for further analysis.

shive
Télécharger la présentation

High-Energy Ground Level Events Measured with Neutron Monitors and the Milagro Instrument

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High-Energy Ground Level Events Measured with Neutron Monitors and the Milagro Instrument James M. Ryan University of New Hampshire and the Milagro Collaboration

  2. The Network • Northeast US • Mount Washington • IGY; Pc = 1.68 GV; 2028 m • Durham • NM64; Pc = 1.88 GV; sea level • Southwest US • Climax • IGY; Pc = 2.96 GV; 3650 m • Milagro • TeV  telescope; Pc = 3.90 GV; 2630 m  = 10.6˚  = 23.2˚ Don Smart; priv. comm.

  3. Concept • Have pairs of detectors with similar cutoffs, similar asymptotic directions but different yield functions. • Each pair provides two integral measures of solar particle spectrum, minimizing anisotropy effects.

  4. For the New Hampshire (northeast US) NMs: • 2000 m of altitude (180 mb) • For the southeast US detectors • 1 GV in cutoff • 1000 m in altitude • NM and muon detector

  5. Technique • For either pair: For well connected events use count-rate differential to estimate shape of proton spectrum. • Absolute amplitude of signal provides normalization. • Two pairs can be used to identify breaking spectrum.

  6. Milagro is a TeV ground-level g-ray telescope. It detects electromagnetic (or hadronic) showers in a 1-acre pond of water, outfitted with photomultiplier tubes. The differential timing signal provides the incident direction, allowing one to identify TeV sources. Crab Nebula

  7. Milagro Cross-sectional schematic Can be either ‘single’ muons or full blown showers produced by galactic or solar cosmic rays. Records rates with differing numbers of ‘hit’ PMTs. Single low-E muons often trigger only 1 PMT, while showers trigger dozens. So-called High Threshold is the lowest threshold, ~5 GV. Charged particles enter the pond and emit Cherenkov light, registered by the photomultiplier tubes.

  8. 1997 November 6 Index Ratio Ratio indicates p–6.2, agreeing with Duldig & Humble (1999) Lockwood et al. 2002

  9. The combined Climax and Milagro data necessitate either a steepening of the spectrum or an abrupt cutoff. Falcone et al. 2003

  10. 2005 January 20 Solar excess ratio between MW and Durham of 1.7 indicates p–6.5 spectrum. Rise time and initial decay in both Climax and Milagro are identical.

  11. Where was the proton acceleration and release? 0631.7 UT* CME (SXI loops) liftoff time (Lin et al. 05) ~560 km-s–1 Solar Wind Speed (Galvin, priv. comm.) Pitch angle cone half angle 20˚ Milagro GLE onset 0652 UT (tenth max) CME speed 2500 km-s–1 (Lin et al. 05)  2.3-2.5 Rs

  12. Extremely fast and intense event rise = 110 s fall = 70 s

  13. Understanding the Acceleration Process Difficulties: 2.3 Rs—shock formation time High CME speed may work 70 s decay—large  in shock sheath (~102 rg) Low total fluence consistent with . Picture may be that shock somehow sets up early, accelerates a few protons quickly but loses them just as quickly.

  14. Complicating factors for Milagro Signal is seen in 6-fold PMT coincidences and higher—indicating high energies. Distribution in multiplicity does not conform to an isotropic distribution. Unfolding spectrum and anisotropy remains to be done. Can be addressed in modeling—no spectrum yet.

More Related